| Literature DB >> 10982677 |
J M Romero1, A Miran, C H Jensen.
Abstract
Tension-band wire fixation of olecranon fractures leads to a high re-operation rate because of the need to remove the metalware. This problem has commonly been thought to be related mainly to the backing-out of the Kirschner wires. A retrospective study was carried out in 55 patients with displaced olecranon fractures operated on with the tension-band wiring technique, in whom there was an overall 71.7% re-operation rate. Complications were few and minor in most patients. The main reason for the removal of the metalware was a direct complaint from the patient (in 61.3% of all removals). A literature review analyzing the causes of metalware removal is also presented.Entities:
Mesh:
Year: 2000 PMID: 10982677 DOI: 10.1007/s007760070036
Source DB: PubMed Journal: J Orthop Sci ISSN: 0949-2658 Impact factor: 1.601