Literature DB >> 10982677

Complications and re-operation rate after tension-band wiring of olecranon fractures.

J M Romero1, A Miran, C H Jensen.   

Abstract

Tension-band wire fixation of olecranon fractures leads to a high re-operation rate because of the need to remove the metalware. This problem has commonly been thought to be related mainly to the backing-out of the Kirschner wires. A retrospective study was carried out in 55 patients with displaced olecranon fractures operated on with the tension-band wiring technique, in whom there was an overall 71.7% re-operation rate. Complications were few and minor in most patients. The main reason for the removal of the metalware was a direct complaint from the patient (in 61.3% of all removals). A literature review analyzing the causes of metalware removal is also presented.

Entities:  

Mesh:

Year:  2000        PMID: 10982677     DOI: 10.1007/s007760070036

Source DB:  PubMed          Journal:  J Orthop Sci        ISSN: 0949-2658            Impact factor:   1.601


  31 in total

1.  Management of bilateral complex fracture-dislocation of proximal ulna and radius: a case report.

Authors:  Giuseppe Giannicola; Erica Manauzzi; Gianluca Cinotti
Journal:  Musculoskelet Surg       Date:  2012-04-22

Review 2.  Fractures in brief: Olecranon fractures.

Authors:  Laura Wiegand; Joseph Bernstein; Jaimo Ahn
Journal:  Clin Orthop Relat Res       Date:  2012-12       Impact factor: 4.176

3.  CORR Insights(®): Factors Associated with Reoperation after Fixation of Displaced Olecranon Fractures.

Authors:  Nash H Naam
Journal:  Clin Orthop Relat Res       Date:  2015-09-11       Impact factor: 4.176

4.  Presentation of the vascular supply of the proximal ulna using a sequential plastination technique.

Authors:  Thomas C Koslowsky; V Berger; J C Hopf; L P Müller
Journal:  Surg Radiol Anat       Date:  2015-04-18       Impact factor: 1.246

5.  [Double-plate osteosynthesis of the proximal ulna].

Authors:  C Ries; K Wegmann; R H Meffert; L P Müller; K J Burkhart
Journal:  Oper Orthop Traumatol       Date:  2015-04-23       Impact factor: 1.154

6.  Repair of comminuted (Mayo type IIB) olecranon fracture using Ethi-bond 5 sutures without metallic implants: A novel technique.

Authors:  Sheng Xu; Heng An Lin; Merng Koon Wong
Journal:  J Orthop       Date:  2019-03-12

7.  Does K-wire position in tension band wiring of olecranon fractures affect its complications and removal of metal rate?

Authors:  K W Chan; K J Donnelly
Journal:  J Orthop       Date:  2014-06-17

8.  Tension band wiring in olecranon fractures: the myth of technical simplicity and osteosynthetical perfection.

Authors:  Marco M Schneider; Tobias E Nowak; Leonard Bastian; Jan C Katthagen; Jörg Isenberg; Pol M Rommens; Lars P Müller; Klaus J Burkhart
Journal:  Int Orthop       Date:  2013-12-12       Impact factor: 3.075

9.  Design and application of nickel-titanium olecranon memory connector in treatment of olecranon fractures: a prospective randomized controlled trial.

Authors:  Xiao Chen; Peng Liu; Xiaofei Zhu; Liehu Cao; Chuncai Zhang; Jiacan Su
Journal:  Int Orthop       Date:  2013-04-18       Impact factor: 3.075

10.  Management of open olecranon fractures using clamp-cum-compressor device.

Authors:  Zile Singh Kundu; P Kamboj; Ss Sangwan; Rc Siwach; Raj Singh; P Walecha
Journal:  Indian J Orthop       Date:  2009-01       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.