Literature DB >> 16333715

Utilization of DICOM GSDF to modify lookup tables for images acquired on film digitizers.

David M Jones1.   

Abstract

Film digitizers are used to transfer hardcopy x-ray transmission films into a PACS environment. Variability between digitizers is primarily due to a lack of an acquisition standard. By utilizing the Digital Imaging and Communications in Medicine (DICOM) Part 14 Grayscale Standard Display Function (GSDF) as basis from which to judge and modify digitizer output, a methodology using Just Noticeable Differences (JND) can be established that will create custom lookup tables for film digitizers. These modified images can then be judged against the original films using the GSDF to determine if the original films' contrast is preserved. Results based on JND indicated that relative contrast of the original image is preserved.

Entities:  

Mesh:

Year:  2006        PMID: 16333715      PMCID: PMC3045188          DOI: 10.1007/s10278-005-9241-z

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  7 in total

1.  A protocol-based evaluation of medical image digitizers.

Authors:  E P Efstathopoulos; L Costaridou; O Kocsis; G Panayiotakis
Journal:  Br J Radiol       Date:  2001-09       Impact factor: 3.039

2.  Contrast information of digital imaging in laser film digitizer and display monitor.

Authors:  S C Lo; J W Gaskill; S K Mun; B H Krasner
Journal:  J Digit Imaging       Date:  1990-05       Impact factor: 4.056

3.  Image calibration of laser digitizers, printers, and gray-scale displays.

Authors:  E L Siegel; A W Templeton; L T Cook; D A Eckard; L A Harrison; S J Dwyer
Journal:  Radiographics       Date:  1992-03       Impact factor: 5.333

4.  Investigation of the imaging properties of an x-ray film scanner.

Authors:  W Döler; S Rassow; A Jäger; R Vosshenrich
Journal:  Phys Med Biol       Date:  1994-05       Impact factor: 3.609

5.  Evaluation of imaging properties of a laser film digitizer.

Authors:  F F Yin; M L Giger; K Doi; H Yoshimura; X W Xu; R M Nishikawa
Journal:  Phys Med Biol       Date:  1992-01       Impact factor: 3.609

6.  Quality assurance of picture archiving communication systems with laser film digitizers.

Authors:  P D Esser; E J Halpern; E S Amis
Journal:  J Digit Imaging       Date:  1991-11       Impact factor: 4.056

7.  The laser film digitizer: density, contrast, and resolution.

Authors:  T N Teslow
Journal:  J Digit Imaging       Date:  1997-08       Impact factor: 4.056

  7 in total
  1 in total

1.  A study on image quality management in PACS used by Korean hospitals.

Authors:  Jae-Hwan Cho; Hae-Kag Lee; Kyung-Rae Dong; Woon-Kwan Chung
Journal:  J Digit Imaging       Date:  2012-12       Impact factor: 4.056

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.