Literature DB >> 20920437

Guidelines for insulin dosing in continuous subcutaneous insulin infusion using new formulas from a retrospective study of individuals with optimal glucose levels.

John Walsh1, Ruth Roberts, Timothy Bailey.   

Abstract

BACKGROUND: Successful insulin pump therapy depends on correct insulin doses based on an optimal total daily dose (TDD) and optimal pump settings for basal infusion, carbohydrate factor (CarbF), and glucose correction factor (CorrF) based on the TDD. There are limited data in the literature to guide providers and patients regarding methods to optimize these critical parameters for glucose control.
METHODS: Anonymous data downloads from 1020 insulin pumps used throughout the United States and overseen by a variety of clinicians were analyzed retrospectively to find insulin doses that provided the best glucose control. A subset of 396 pumps was chosen for glucose data reliability, with over 85% of their glucose data directly entered from a meter. This subset was divided into tertiles based on glucose levels, and the low glucose tertile was analyzed to derive formulas for optimal insulin pump settings.
RESULTS: An inconsistent clustering of pump settings was found for the CarbF and the CorrF. This was less pronounced when CarbFs and CorrFs were determined from the actual bolus doses delivered once adjustments were made to the initial dose calculations by users and, to a larger extent, internally by the bolus calculator itself. Common beliefs that hyperglycemia is related to less carb counting, fewer carb boluses, or delivery of less insulin per day were not substantiated in this data. New or verified insulin dosing formulas presented include basal U/day = TDD × 0.48; CarbF = [2.6 × Wt(lb)]/TDD; and CorrF = 1960/TDD.
CONCLUSIONS: Insulin pump users cannot reap full benefit from their pump bolus calculator if the settings on which bolus doses are based are less than optimal. Our data show that CarbFs and CorrFs tend to be unevenly distributed, suggesting that these factors are not selected in a systematic manner through use of formulas. Poor glucose outcomes among insulin pump users appear to be related to pump setting errors and being relatively underinsulinized, even though those in poor control use more total insulin per day. We have developed a model with the hypothesis that improved glucose outcomes will result from the use of formulas to derive appropriate pump settings. Prospective validation of these concepts is needed.
© 2010 Diabetes Technology Society.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20920437      PMCID: PMC2956816          DOI: 10.1177/193229681000400516

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  2 in total

1.  A prospective evaluation of insulin dosing recommendations in patients with type 1 diabetes at near normal glucose control: bolus dosing.

Authors:  Allen B King; Dana U Armstrong
Journal:  J Diabetes Sci Technol       Date:  2007-01

2.  Analysis of guidelines for basal-bolus insulin dosing: basal insulin, correction factor, and carbohydrate-to-insulin ratio.

Authors:  Paul C Davidson; Harry R Hebblewhite; Robert D Steed; Bruce W Bode
Journal:  Endocr Pract       Date:  2008-12       Impact factor: 3.443

  2 in total
  32 in total

1.  Commentary on "Performance of a glucose meter with a built-in automated bolus calculator versus manual bolus calculation in insulin-using subjects".

Authors:  Paolo Rossetti; Josep Vehí; Ana Revert; Remei Calm; Jorge Bondia
Journal:  J Diabetes Sci Technol       Date:  2012-03-01

2.  Bolus calculator settings in well-controlled type 1 diabetes patients (glycated hemoglobin < 7%) treated with insulin pumps.

Authors:  Bartłomiej Matejko; Małgorzata Grzanka; Beata Kieć-Wilk; Maciej T Małecki; Tomasz Klupa
Journal:  J Diabetes Sci Technol       Date:  2013-05-01

3.  Event and Cost Offsets of Switching 20% of the Type 1 Diabetes Population in Germany From Multiple Daily Injections to Continuous Subcutaneous Insulin Infusion: A 4-Year Simulation Model.

Authors:  York Francis Zöllner; Ralph Ziegler; Magnus Stüve; Julia Krumreich; Marion Schauf
Journal:  J Diabetes Sci Technol       Date:  2016-08-22

Review 4.  Boluses in Insulin Therapy.

Authors:  Ralph Ziegler; Guido Freckmann; Lutz Heinemann
Journal:  J Diabetes Sci Technol       Date:  2016-07-10

Review 5.  Perioperative management of endocrine insufficiency after total pancreatectomy for neoplasia.

Authors:  Ajay V Maker; Raashid Sheikh; Vinita Bhagia
Journal:  Langenbecks Arch Surg       Date:  2017-07-21       Impact factor: 3.445

Review 6.  Bolus Advisors: Sources of Error, Targets for Improvement.

Authors:  John Walsh; Ruth Roberts; Timothy S Bailey; Lutz Heinemann
Journal:  J Diabetes Sci Technol       Date:  2017-07-25

7.  Bolus Calculator Safety Mandates a Need for Standards.

Authors:  John Walsh; Guido Freckmann; Ruth Roberts; Lutz Heinemann
Journal:  J Diabetes Sci Technol       Date:  2016-12-20

8.  Establishing Methods to Determine Clinically Relevant Bolus and Basal Rate Delivery Accuracy of Insulin Pumps.

Authors:  Ulrike Kamecke; Delia Waldenmaier; Cornelia Haug; Ralph Ziegler; Guido Freckmann
Journal:  J Diabetes Sci Technol       Date:  2018-07-13

Review 9.  Bolus calculators.

Authors:  Signe Schmidt; Kirsten Nørgaard
Journal:  J Diabetes Sci Technol       Date:  2014-05-19

10.  We Need More Research and Better Designs for Insulin Infusion Sets.

Authors:  Lutz Heinemann; John Walsh; Ruth Roberts
Journal:  J Diabetes Sci Technol       Date:  2014-02-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.