Literature DB >> 19158048

Analysis of guidelines for basal-bolus insulin dosing: basal insulin, correction factor, and carbohydrate-to-insulin ratio.

Paul C Davidson1, Harry R Hebblewhite, Robert D Steed, Bruce W Bode.   

Abstract

OBJECTIVE: To analyze and compare the underlying mathematical models for basal-bolus insulin-dosing guidelines in patients with type 1 diabetes in a retrospective controlled study.
METHODS: Algebraic model-development yielded several systems of models with unknown constants, including 3 systems currently in use. These systems were compared for logic and consistency. One of these systems was the accurate insulin management (AIM) system, which we developed in the setting of our large endocrine practice. Our database consisted of retrospective clinical records for a 7-month period. During this time, correction factor (CF), carbohydrate-to-insulin ratio (CIR), and basal insulin were being adjusted incrementally by titration. The variables studied were height, body weight in pounds (BWlb), CF, CIR, hemoglobin A1c (A1C), basal insulin, and 6-day mean total daily dose of insulin (TDD). The values of the variables used in the study were those determined on arrival of the patients at the office. The last 6 TDDs were entered into the database, and the mean was calculated by formulas within the database. We sorted our database into 2 groups, a well-controlled test group (n = 167; A1C <or=7%, time on pump >180 days, no severe hypoglycemic events since the last office visit, and C-peptide level <or=0.5 ng/mL) and a control group with poor control (n = 209; A1C >7% or time on pump <180 days). We obtained one office visit per patient, as follows: from the test group, we chose the visit with the lowest A1C value; from the control group, we chose one visit by use of a computer's random number generator. A significant difference was demonstrated between the correlation constants of the test group versus the control group by performing T tests between the means and F tests between the standard deviations. The least squares estimates of the correlation constants from the test group were recommended in the guidelines, in place of the means, to gain accuracy. By these methods, the guidelines used by the patients with good glycemic control are made available for all patients.
RESULTS: With use of the AIM system, the TDD for continuous subcutaneous insulin infusion = 0.24 * BWlb; basal insulin = 0.47 * TDD; CF = 1,700/TDD; and CIR = 2.8 * BWlb/TDD.
CONCLUSION: Three mathematical models for CIR are presented, with a rationale for supporting one of them (the AIM model). This model, together with 3 related AIM models, when provided with statistically correlated constants, constitutes the AIM system of guidelines, a consistent and convenient means of estimating insulin-dosing variables for patients with type 1 diabetes.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19158048     DOI: 10.4158/EP.14.9.1095

Source DB:  PubMed          Journal:  Endocr Pract        ISSN: 1530-891X            Impact factor:   3.443


  41 in total

1.  Guidelines for insulin dosing in continuous subcutaneous insulin infusion using new formulas from a retrospective study of individuals with optimal glucose levels.

Authors:  John Walsh; Ruth Roberts; Timothy Bailey
Journal:  J Diabetes Sci Technol       Date:  2010-09-01

Review 2.  Continuous glucose monitoring-guided insulin dosing in pump-treated patients with type 1 diabetes: a clinical guide.

Authors:  Allen B King
Journal:  J Diabetes Sci Technol       Date:  2012-01-01

3.  Design and in silico evaluation of an intraperitoneal-subcutaneous (IP-SC) artificial pancreas.

Authors:  Justin J Lee; Eyal Dassau; Howard Zisser; Francis J Doyle
Journal:  Comput Chem Eng       Date:  2014-11-05       Impact factor: 3.845

Review 4.  Bolus Advisors: Sources of Error, Targets for Improvement.

Authors:  John Walsh; Ruth Roberts; Timothy S Bailey; Lutz Heinemann
Journal:  J Diabetes Sci Technol       Date:  2017-07-25

5.  In Silico Assessment of Literature Insulin Bolus Calculation Methods Accounting for Glucose Rate of Change.

Authors:  Giacomo Cappon; Francesca Marturano; Martina Vettoretti; Andrea Facchinetti; Giovanni Sparacino
Journal:  J Diabetes Sci Technol       Date:  2018-05-31

Review 6.  Practical use of self-monitoring of blood glucose data.

Authors:  Barry H Ginsberg
Journal:  J Diabetes Sci Technol       Date:  2013-03-01

Review 7.  Bolus calculators.

Authors:  Signe Schmidt; Kirsten Nørgaard
Journal:  J Diabetes Sci Technol       Date:  2014-05-19

Review 8.  Management of Type 1 Diabetes in the Hospital Setting.

Authors:  Carlos E Mendez; Guillermo E Umpierrez
Journal:  Curr Diab Rep       Date:  2017-09-14       Impact factor: 4.810

9.  Bolus Calculator Settings in Well-Controlled Prepubertal Children Using Insulin Pumps Are Characterized by Low Insulin to Carbohydrate Ratios and Short Duration of Insulin Action Time.

Authors:  Ragnar Hanas; Peter Adolfsson
Journal:  J Diabetes Sci Technol       Date:  2016-07-29

10.  A Simplified Approach Using Rate of Change Arrows to Adjust Insulin With Real-Time Continuous Glucose Monitoring.

Authors:  David C Klonoff; David Kerr
Journal:  J Diabetes Sci Technol       Date:  2017-09-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.