Literature DB >> 20885019

DigiWarp: a method for deformable mouse atlas warping to surface topographic data.

Anand A Joshi1, Abhijit J Chaudhari, Changqing Li, Joyita Dutta, Simon R Cherry, David W Shattuck, Arthur W Toga, Richard M Leahy.   

Abstract

For pre-clinical bioluminescence or fluorescence optical tomography, the animal's surface topography and internal anatomy need to be estimated for improving the quantitative accuracy of reconstructed images. The animal's surface profile can be measured by all-optical systems, but estimation of the internal anatomy using optical techniques is non-trivial. A 3D anatomical mouse atlas may be warped to the estimated surface. However, fitting an atlas to surface topography data is challenging because of variations in the posture and morphology of imaged mice. In addition, acquisition of partial data (for example, from limited views or with limited sampling) can make the warping problem ill-conditioned. Here, we present a method for fitting a deformable mouse atlas to surface topographic range data acquired by an optical system. As an initialization procedure, we match the posture of the atlas to the posture of the mouse being imaged using landmark constraints. The asymmetric L(2) pseudo-distance between the atlas surface and the mouse surface is then minimized in order to register two data sets. A Laplacian prior is used to ensure smoothness of the surface warping field. Once the atlas surface is normalized to match the range data, the internal anatomy is transformed using elastic energy minimization. We present results from performance evaluation studies of our method where we have measured the volumetric overlap between the internal organs delineated directly from MRI or CT and those estimated by our proposed warping scheme. Computed Dice coefficients indicate excellent overlap in the brain and the heart, with fair agreement in the kidneys and the bladder.

Entities:  

Mesh:

Year:  2010        PMID: 20885019      PMCID: PMC3051844          DOI: 10.1088/0031-9155/55/20/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  44 in total

1.  Fluorescence-enhanced optical tomography using referenced measurements of heterogeneous media.

Authors:  Ranadhir Roy; Anuradha Godavarty; Eva M Sevick-Muraca
Journal:  IEEE Trans Med Imaging       Date:  2003-07       Impact factor: 10.048

2.  Uniqueness theorems in bioluminescence tomography.

Authors:  Ge Wang; Yi Li; Ming Jiang
Journal:  Med Phys       Date:  2004-08       Impact factor: 4.071

3.  A born-type approximation method for bioluminescence tomography.

Authors:  Wenxiang Cong; Kumar Durairaj; Lihong V Wang; Ge Wang
Journal:  Med Phys       Date:  2006-03       Impact factor: 4.071

4.  Effect of optical property estimation accuracy on tomographic bioluminescence imaging: simulation of a combined optical-PET (OPET) system.

Authors:  George Alexandrakis; Fernando R Rannou; Arion F Chatziioannou
Journal:  Phys Med Biol       Date:  2006-04-03       Impact factor: 3.609

5.  Digimouse: a 3D whole body mouse atlas from CT and cryosection data.

Authors:  Belma Dogdas; David Stout; Arion F Chatziioannou; Richard M Leahy
Journal:  Phys Med Biol       Date:  2007-01-10       Impact factor: 3.609

6.  A 3D deformable surface model for segmentation of objects from volumetric data in medical images.

Authors:  A Ghanei; H Soltanian-Zadeh; J P Windham
Journal:  Comput Biol Med       Date:  1998-05       Impact factor: 4.589

7.  Excitation spectroscopy in multispectral optical fluorescence tomography: methodology, feasibility and computer simulation studies.

Authors:  Abhijit J Chaudhari; Sangtae Ahn; Richard Levenson; Ramsey D Badawi; Simon R Cherry; Richard M Leahy
Journal:  Phys Med Biol       Date:  2009-07-10       Impact factor: 3.609

8.  A three-dimensional multispectral fluorescence optical tomography imaging system for small animals based on a conical mirror design.

Authors:  Changqing Li; Gregory S Mitchell; Joyita Dutta; Sangtae Ahn; Richard M Leahy; Simon R Cherry
Journal:  Opt Express       Date:  2009-04-27       Impact factor: 3.894

9.  Visualization of antitumor treatment by means of fluorescence molecular tomography with an annexin V-Cy5.5 conjugate.

Authors:  Vasilis Ntziachristos; Eyk A Schellenberger; Jorge Ripoll; Doreen Yessayan; Edward Graves; Alexei Bogdanov; Lee Josephson; Ralph Weissleder
Journal:  Proc Natl Acad Sci U S A       Date:  2004-08-10       Impact factor: 11.205

10.  A multimodal, multidimensional atlas of the C57BL/6J mouse brain.

Authors:  Allan MacKenzie-Graham; Erh-Fang Lee; Ivo D Dinov; Mihail Bota; David W Shattuck; Seth Ruffins; Heng Yuan; Fotios Konstantinidis; Alain Pitiot; Yi Ding; Guogang Hu; Russell E Jacobs; Arthur W Toga
Journal:  J Anat       Date:  2004-02       Impact factor: 2.610

View more
  11 in total

1.  A hybrid registration-based method for whole-body micro-CT mice images.

Authors:  Xiaochao Qu; Xueyuan Gao; Xianhui Xu; Shouping Zhu; Jimin Liang
Journal:  Med Biol Eng Comput       Date:  2015-09-21       Impact factor: 2.602

2.  Canny edge-based deformable image registration.

Authors:  Vasant Kearney; Yihui Huang; Weihua Mao; Baohong Yuan; Liping Tang
Journal:  Phys Med Biol       Date:  2017-01-12       Impact factor: 3.609

3.  MORPHOMETRY FOR EARLY MONITORING OF TREATMENT RESPONSE IN RHEUMATOID ARTHRITIS.

Authors:  Anand A Joshi; Richard M Leahy; Ramsey D Badawi; Abhijit J Chaudhari
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2013

4.  Mouse atlas registration with non-tomographic imaging modalities-a pilot study based on simulation.

Authors:  Hongkai Wang; David B Stout; Arion F Chatziioannou
Journal:  Mol Imaging Biol       Date:  2012-08       Impact factor: 3.488

5.  Joint L1 and total variation regularization for fluorescence molecular tomography.

Authors:  Joyita Dutta; Sangtae Ahn; Changqing Li; Simon R Cherry; Richard M Leahy
Journal:  Phys Med Biol       Date:  2012-03-05       Impact factor: 3.609

6.  A method of 2D/3D registration of a statistical mouse atlas with a planar X-ray projection and an optical photo.

Authors:  Hongkai Wang; David B Stout; Arion F Chatziioannou
Journal:  Med Image Anal       Date:  2013-03-05       Impact factor: 8.545

7.  Registration-Based Morphometry for Shape Analysis of the Bones of the Human Wrist.

Authors:  Anand A Joshi; Richard M Leahy; Ramsey D Badawi; Abhijit J Chaudhari
Journal:  IEEE Trans Med Imaging       Date:  2016-02       Impact factor: 10.048

8.  Estimation of mouse organ locations through registration of a statistical mouse atlas with micro-CT images.

Authors:  Hongkai Wang; David B Stout; Arion F Chatziioannou
Journal:  IEEE Trans Med Imaging       Date:  2011-08-18       Impact factor: 10.048

9.  A Method for Automated Cortical Surface Registration and Labeling.

Authors:  Anand A Joshi; David W Shattuck; Richard M Leahy
Journal:  Biomed Image Regist Proc       Date:  2012-07

10.  Multimodal Correlative Preclinical Whole Body Imaging and Segmentation.

Authors:  Ayelet Akselrod-Ballin; Hagit Dafni; Yoseph Addadi; Inbal Biton; Reut Avni; Yafit Brenner; Michal Neeman
Journal:  Sci Rep       Date:  2016-06-21       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.