Literature DB >> 20869902

A non-rigid registration method for serial lower extremity hybrid SPECT/CT imaging.

Jung W Suh1, Dustin Scheinost, Donald P Dione, Lawrence W Dobrucki, Albert J Sinusas, Xenophon Papademetris.   

Abstract

Small animal X-ray computed tomographic (microCT) imaging of the lower extremities permits evaluation of arterial growth in models of hindlimb ischemia, and when applied serially can provide quantitative information about disease progression and aid in the evaluation of therapeutic interventions. The quantification of changes in tissue perfusion and concentration of molecular markers concurrently obtained using nuclear imaging requires the ability to non-rigidly register the microCT images over time, a task made more challenging by the potentially large changes in the positions of the legs due to articulation. While non-rigid registration methods have been extensively used in the evaluation of individual organs, application in whole body imaging has been limited, primarily because the scale of possible displacements and deformations is large resulting in poor convergence of most methods. In this paper we present a new method based on the extended demons algorithm that uses a level-set representation of the body contour and skeletal structure as an input. The proposed serial registration method reflects the natural physical moving combination of mouse anatomy in which the movement of bones is the framework for body movements, and the movement of skin constrains the detailed movements of the specific segmented body regions. We applied our method to both the registration of serial microCT mouse images and the quantification of microSPECT component of the serially hybrid microCT-SPECT images demonstrating improved performance as compared to existing registration techniques.
Copyright © 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20869902      PMCID: PMC2988883          DOI: 10.1016/j.media.2010.08.002

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  28 in total

1.  Three-dimensional multimodal brain warping using the demons algorithm and adaptive intensity corrections.

Authors:  A Guimond; A Roche; N Ayache; J Meunier
Journal:  IEEE Trans Med Imaging       Date:  2001-01       Impact factor: 10.048

2.  Nonrigid registration using free-form deformations: application to breast MR images.

Authors:  D Rueckert; L I Sonoda; C Hayes; D L Hill; M O Leach; D J Hawkes
Journal:  IEEE Trans Med Imaging       Date:  1999-08       Impact factor: 10.048

3.  Spatial transformation and registration of brain images using elastically deformable models.

Authors:  C Davatzikos
Journal:  Comput Vis Image Underst       Date:  1997-05       Impact factor: 3.876

4.  POSTURE MATCHING AND ELASTIC REGISTRATION OF A MOUSE ATLAS TO SURFACE TOPOGRAPHY RANGE DATA.

Authors:  A A Joshi; A J Chaudhari; Changqing Li; D W Shattuck; J Dutta; R M Leahy; A W Toga
Journal:  Proc IEEE Int Symp Biomed Imaging       Date:  2009-08-07

5.  Diffeomorphic demons: efficient non-parametric image registration.

Authors:  Tom Vercauteren; Xavier Pennec; Aymeric Perchant; Nicholas Ayache
Journal:  Neuroimage       Date:  2008-11-07       Impact factor: 6.556

6.  Peripheral arterial disease in the elderly: The Rotterdam Study.

Authors:  W T Meijer; A W Hoes; D Rutgers; M L Bots; A Hofman; D E Grobbee
Journal:  Arterioscler Thromb Vasc Biol       Date:  1998-02       Impact factor: 8.311

7.  Validation of an accelerated 'demons' algorithm for deformable image registration in radiation therapy.

Authors:  He Wang; Lei Dong; Jennifer O'Daniel; Radhe Mohan; Adam S Garden; K Kian Ang; Deborah A Kuban; Mark Bonnen; Joe Y Chang; Rex Cheung
Journal:  Phys Med Biol       Date:  2005-06-01       Impact factor: 3.609

8.  Integrin receptor imaging of breast cancer: a proof-of-concept study to evaluate 99mTc-NC100692.

Authors:  Tore Bach-Gansmo; Rimma Danielsson; Ariel Saracco; Brigitte Wilczek; Trond V Bogsrud; Anne Fangberget; Ase Tangerud; Derek Tobin
Journal:  J Nucl Med       Date:  2006-09       Impact factor: 10.057

9.  Image-based dose planning of intracavitary brachytherapy: registration of serial-imaging studies using deformable anatomic templates.

Authors:  G E Christensen; B Carlson; K S Chao; P Yin; P W Grigsby; K Nguyen; J F Dempsey; F A Lerma; K T Bae; M W Vannier; J F Williamson
Journal:  Int J Radiat Oncol Biol Phys       Date:  2001-09-01       Impact factor: 7.038

Review 10.  Genetic targeting for cardiovascular therapeutics: are we near the summit or just beginning the climb?

Authors:  S C Francis; M K Raizada; A A Mangi; L G Melo; V J Dzau; P R Vale; J M Isner; D W Losordo; J Chao; M J Katovich; K H Berecek
Journal:  Physiol Genomics       Date:  2001-12-21       Impact factor: 3.107

View more
  6 in total

1.  Deformable image registration for cone-beam CT guided transoral robotic base-of-tongue surgery.

Authors:  S Reaungamornrat; W P Liu; A S Wang; Y Otake; S Nithiananthan; A Uneri; S Schafer; E Tryggestad; J Richmon; J M Sorger; J H Siewerdsen; R H Taylor
Journal:  Phys Med Biol       Date:  2013-06-27       Impact factor: 3.609

2.  Noninvasive In Vivo Quantification of Adeno-Associated Virus Serotype 9-Mediated Expression of the Sodium/Iodide Symporter Under Hindlimb Ischemia and Neuraminidase Desialylation in Skeletal Muscle Using Single-Photon Emission Computed Tomography/Computed Tomography.

Authors:  Nabil E Boutagy; Silvia Ravera; Xenophon Papademetris; John A Onofrey; Zhen W Zhuang; Jing Wu; Attila Feher; Mitchel R Stacy; Brent A French; Brian H Annex; Nancy Carrasco; Albert J Sinusas
Journal:  Circ Cardiovasc Imaging       Date:  2019-07-12       Impact factor: 7.792

3.  CT-PET weighted image fusion for separately scanned whole body rat.

Authors:  Jung W Suh; Oh-Kyu Kwon; Dustin Scheinost; Albert J Sinusas; Gary W Cline; Xenophon Papademetris
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

Review 4.  PET/SPECT imaging of hindlimb ischemia: focusing on angiogenesis and blood flow.

Authors:  Hakan Orbay; Hao Hong; Yin Zhang; Weibo Cai
Journal:  Angiogenesis       Date:  2012-11-02       Impact factor: 9.596

5.  A Robust and Accurate Non-rigid Medical Image Registration Algorithm Based on Multi-level Deformable Model.

Authors:  Yanli Wan; Hongpu Hu; Yanli Xu; Quan Chen; Yan Wang; Dongping Gao
Journal:  Iran J Public Health       Date:  2017-12       Impact factor: 1.429

6.  Segmentation and visual analysis of whole-body mouse skeleton microSPECT.

Authors:  Artem Khmelinskii; Harald C Groen; Martin Baiker; Marion de Jong; Boudewijn P F Lelieveldt
Journal:  PLoS One       Date:  2012-11-12       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.