Fernanda Cp Pires de Souza1, Luiz C Pardini, Diogo R Cruvinel, Hisham M Hamida, Lucas Fr Garcia.
Abstract
AIM: To compare the optical densities (OD) of calcium hydroxide (CH) and glass ionomer cement with the same thicknesses of the dental structures.Entities:
Keywords: Calcium hydroxide; dentin; enamel; glass ionomer cement; radiopacity
Year: 2010 PMID: 20859477 PMCID: PMC2936092 DOI: 10.4103/0972-0707.66713
Source DB: PubMed Journal: J Conserv Dent ISSN: 0972-0707
Materials used in the study
| Material | Commercial brand | Manufacturer |
|---|---|---|
| Calcium hydroxide cement | Hydro-C | Dentsply (Duque de Caxias, RJ, Brasil) |
| Glass ionomer cement | Vivaglass liner | Ivoclar / Vivadent (Schaan, Liechtenstein) |
Figure 1Standardizing device used to determine optical density of the tested materials
Figure 2Dental cuts (cervical region - mesio-distal direction)
Figure 3Teflon matrix used to make the test specimens
Figure 4Standardizing device assembled with cements (ce), dental cuts (dt), occlusal film (of), and penetrometer (pt)
Mean optical density values (SD) for the tested materials, enamel and dentin (two-way ANOVA, Bonferroni test, P < 0.05)
| CH | GIC | Enamel | Dentin | |
|---|---|---|---|---|
| 0.5 | 2.14 (0.14)a,A | 2.12 (0.08)a,A | 2.33 (0.06)b.A | 2.36 (0.11)b.A |
| 1.0 | 1.71 (0.09)a,B | 1.87 (0.03)b,B | 1.92 (0.07)c.B | 2.08 (0.05)c.B |
| 1.5 | 1.56 (0.02)a,C | 1.59 (0.11)ab,B | 1.68 (0.07)ab.C | 1.75 (0.10)b.C |
| 2.0 | 1.38 (0.04)a,D | 1.48 (0.04)a,B | 1.46 (0.04)a.D | 1.64 (0.03)b.C |
| 2.5 | 1.16 (0.02)a,E | 1.19 (0.02)a,C | 1.37 (0.05)b.DE | 1.59 (0.04)c.C |
| 3.0 | 1.15 (0.03)ab,E | 1.01 (0.02)b,D | 1.25 (0.07)a.E | 1.45 (0.08)c.D |
Different letters, lower case in columns and capitals in lines, indicate significant difference
Figure 5Graphic representation of the comparison of OD means of the tested materials and the dental structures