Polyethylene terephthalate clamps: Optimization in endodontic and restorative practices.

Anna-Flávia Ferreira E Cunha1, Isabela-Ribeiro Madalena2,3,4, Erika-Calvano Küchler5, Tiago-Lima Pereira1, Richard Honorato1, Fernando-Carlos-Hueb de Menezes1, César-Penazzo Lepri1, Maria-Angélica-Hueb-de Menezes Oliveira1.   

Abstract

Background: There is a growing search for innovations in dental materials and instruments and, therefore, an increase need to optimize the instruments used in the absolute isolation. The gold standard procedure contributes significantly to the quality of restorative and endodontic procedures. Thus, the aim of the present study was to evaluate the radiopacity of polyethylene terephthalate polymer clamps and compare them to conventional metal clamps. Material and
Methods: The polyethylene terephthalate clamp was developed at the University of Uberaba (Patent application #PI0901719-4, Uberaba, MG, Brazil). Five polyethylene terephthalate clamps and five conventional metal clamps were used. The clamps were positioned, next to an aluminum scale, under the same phosphor plate to perform 3 radiographs. The locator cylinder was set perpendicular to the radiographic films at a focal length of 20 cm and set to 60 kVp and 0.06 seconds. After image processing, optical density values were read using DBWin 5.0.4 software. The mean of the 3 readings taken on each clamp was adopted as the radiodensity of the specimen. The differences between the groups were compared using Student's t-test (p<0.05).
Results: Polyethylene terephthalate clamps demonstrated significantly lower radiopacity than conventional metal clamps (p<0.05). Conclusions: Polyethylene terephthalate clamps have lower radiopacity when compared to conventional metal clamps. Key words:Rubber Dams, Dentistry, Operative, Endodontics. Copyright:
© 2022 Medicina Oral S.L.

Entities:  

Year:  2022        PMID: 36046164      PMCID: PMC9422974          DOI: 10.4317/jced.59603

Source DB:  PubMed          Journal:  J Clin Exp Dent        ISSN: 1989-5488


  16 in total

1.  Influence of rubber dam on objective and subjective parameters of stress during dental treatment of children and adolescents - a randomized controlled clinical pilot study.

Authors:  Patricia Ammann; Andreas Kolb; Adrian Lussi; Rainer Seemann
Journal:  Int J Paediatr Dent       Date:  2012-03-08       Impact factor: 3.455

2.  Rubber dam use during routine operative dentistry procedures: findings from the Dental PBRN.

Authors:  Gregg H Gilbert; Mark S Litaker; Daniel J Pihlstrom; Craig W Amundson; Valeria V Gordan
Journal:  Oper Dent       Date:  2010 Sep-Oct       Impact factor: 2.440

Review 3.  Rubber dam usage for endodontic treatment: a review.

Authors:  I A Ahmad
Journal:  Int Endod J       Date:  2009-11       Impact factor: 5.264

4.  Influence of different rubber dam application on intraoral temperature and relative humidity.

Authors:  Akiko Haruyama; Atsushi Kameyama; Chihiro Tatsuta; Kurumi Ishii; Toshiko Sugiyama; Setsuko Sugiyama; Toshiyuki Takahashi
Journal:  Bull Tokyo Dent Coll       Date:  2014

5.  An internet-mediated investigation into the reported clinical use of rubber dam isolation by GDPs in the UK - part 1: factors influencing rubber dam use.

Authors:  Daniel Çağa; Anne-Maria Brennan; Kenneth Eaton
Journal:  Br Dent J       Date:  2021-06-25       Impact factor: 1.626

6.  The impact of an enhanced infection control protocol on molar root canal treatment outcome - a randomised clinical trial.

Authors:  Shatha Zahran; Shanon Patel; Garrit Koller; Francesco Mannocci
Journal:  Int Endod J       Date:  2021-08-05       Impact factor: 5.264

7.  In vitro comparison of the radiopacity of cavity lining materials with human dental structures.

Authors:  Fernanda Cp Pires de Souza; Luiz C Pardini; Diogo R Cruvinel; Hisham M Hamida; Lucas Fr Garcia
Journal:  J Conserv Dent       Date:  2010-04

8.  Dental dam clamp adaptation method on carved gypsum cast.

Authors:  N C E Cazacu
Journal:  J Med Life       Date:  2014 Oct-Dec

9.  Why dentists don't use rubber dam during endodontics and how to promote its usage?

Authors:  Ahmad A Madarati
Journal:  BMC Oral Health       Date:  2016-02-25       Impact factor: 2.757

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.