Literature DB >> 20846746

Assessment of horizontal laminar air flow instrument table for additional ultraclean space during surgery.

K-G Nilsson1, R Lundholm, S Friberg.   

Abstract

The area in a vertical ultraclean laminar air flow (LAF) theatre is usually too small to accommodate all the equipment needed for major surgery. We investigated the addition of an instrument table supplied with fixed ultraclean LAF and placed alongside the existing main LAF unit, to determine its physical and bacteriological effect on the main unit. In phase 1, with two investigators but without a patient, smoke tests showed no intrusion of air from the table into the main unit and particle counts did not show any adverse effect on the main LAF unit. In phase 2, during patients undergoing two total knee replacements, the LAF table and a table without LAF were placed alongside the main LAF unit. The tables were subjected to the activity of an extra operating room (OR) nurse working from inside the main LAF vigorously simulating handling of instruments. During this activity, the >5μm particle counts were 275/m(3) at the instrument table with LAF and 8550/m(3) at the table without LAF (P<0.0001). Also, without the OR nurse activity, the particle counts, just inside the main unit and adjacent to the LAF table, were significantly reduced (P<0.03-0.003). Sedimentation plates on the LAF table and in the main unit registered 22 and 25cfu/m(2)/h respectively compared with 45cfu/m(2)/h at the instrument table without LAF. In conclusion, the results from the smoke tests, particle counts and bacteriological evaluation showed that the additional instrument table supplied with LAF is efficient and can be safely used as an extension additional to a main OR LAF unit.
Copyright © 2010 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20846746     DOI: 10.1016/j.jhin.2010.05.016

Source DB:  PubMed          Journal:  J Hosp Infect        ISSN: 0195-6701            Impact factor:   3.926


  6 in total

1.  Laminar air flow reduces particle load in TKA-even outside the LAF panel: a prospective, randomized cohort study.

Authors:  Stephanie Kirschbaum; Hagen Hommel; Peggy Strache; Roland Horn; Roman Falk; Carsten Perka
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-11-09       Impact factor: 4.342

2.  Instrument tables equipped with local unidirectional airflow units reduce bacterial contamination during orthopedic implant surgery in an operating room with a displacement ventilation system.

Authors:  Josefin Seth Caous; Karin Svensson Malchau; Max Petzold; Ylva Fridell; Henrik Malchau; Linda Ahlstrom; Peter Grant; Annette Erichsen Andersson
Journal:  Infect Prev Pract       Date:  2022-05-26

3.  Single-use instrumentation in posterior lumbar fusion could decrease incidence of surgical site infection: a prospective bi-centric study.

Authors:  Stéphane Litrico; Geoffrey Recanati; Antoine Gennari; Cédric Maillot; Mo Saffarini; Jean-Charles Le Huec
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-09-01

4.  Does a mobile laminar airflow screen reduce bacterial contamination in the operating room? A numerical study using computational fluid dynamics technique.

Authors:  Sasan Sadrizadeh; Ann Tammelin; Peter V Nielsen; Sture Holmberg
Journal:  Patient Saf Surg       Date:  2014-06-26

5.  Mobile ultra-clean unidirectional airflow screen reduces air contamination in a simulated setting for intra-vitreal injection.

Authors:  Ruth Lapid-Gortzak; Roberto Traversari; Jan Willem van der Linden; Sarit Y Lesnik Oberstein; Oren Lapid; Reinier O Schlingemann
Journal:  Int Ophthalmol       Date:  2016-04-30       Impact factor: 2.031

6.  A systematic review and meta-analysis of indoor bioaerosols in hospitals: The influence of heating, ventilation, and air conditioning.

Authors:  Rongchen Dai; Shan Liu; Qiushuang Li; Hanting Wu; Li Wu; Conghua Ji
Journal:  PLoS One       Date:  2021-12-23       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.