| Literature DB >> 20846378 |
Kok-Thye Yip1, Prashanta K Das, David Suria, Chun-Ren Lim, Guey-Hooi Ng, Choong-Chin Liew.
Abstract
BACKGROUND: Colorectal cancer (CRC) screening is key to CRC prevention and mortality reduction, but patient compliance with CRC screening is low. We previously reported a blood-based test for CRC that utilizes a seven-gene panel of biomarkers. The test is currently utilized clinically in North America for CRC risk stratification in the average-risk North American population in order to improve screening compliance and to enhance clinical decision making.Entities:
Mesh:
Substances:
Year: 2010 PMID: 20846378 PMCID: PMC2949823 DOI: 10.1186/1756-9966-29-128
Source DB: PubMed Journal: J Exp Clin Cancer Res ISSN: 0392-9078
Blood Specimen Collection and RNA Sample Quality Statistics
| Collection Date | RNA QC | CASES | |
|---|---|---|---|
| Control | CRC | ||
| August 2007 | PASS | 301 | 107 |
| To | FAIL | 8 | 5 |
| November 2009 | Subtotal | 309 | 112 |
| Total | 421 | ||
| Passing Rate | 96.9% | ||
Gender and Age Distribution in the Study Samples
| Age | ≤ 30 | 31 - 50 | 51 - 70 | 71 - 90 | ≥ 91 | Total | Median Age | |
|---|---|---|---|---|---|---|---|---|
| Control | Male | 0 | 7 | 37 | 12 | 0 | 56 | 64 |
| Female | 1 | 14 | 31 | 9 | 0 | 55 | 61 | |
| CRC | Male | 0 | 7 | 26 | 18 | 0 | 51 | 66 |
| Female | 1 | 11 | 22 | 12 | 2 | 48 | 62 | |
| Total Sample No. | 2 | 39 | 116 | 51 | 2 | 210 | ||
Racial/Ethnic Composition of North American and Malaysian Samples
| Patient Race/Ethnicity | North American | Malaysian | ||||
|---|---|---|---|---|---|---|
| Training Set | Test Set | |||||
| Control | CRC | Control | CRC | Control | CRC | |
| Number | 120 | 112 | 208 | 202 | 111 | 99 |
| White | 101 (84.2) | 91 (81.3) | 162 (77.9) | 138 (68.3) | 1 (0.9) | |
| Black | 7 (5.8) | 7 (6.2) | 8 (3.9) | 8 (4.0) | ||
| Asian | 9 (7.5) | 6 (5.4) | 32 (15.4) | 35 (17.3) | ||
| Chinese | 74 (66.7) | 70 (70.7) | ||||
| Indian, East | 2 (1.8) | 3 (3.0) | ||||
| Indonesian | 32 (28.8) | 21 (21.2) | ||||
| Malay | 2 (1.8) | 5 (5.1) | ||||
| Others | 3 (2.5) | 8 (7.1) | 6 (2.8) | 5 (2.5) | ||
| Not Available | 16 (7.9) | |||||
Note: Percentages within individual cohort are shown in brackets.
Figure 1Comparison of the Expression of Six Genes of Interest (ANXA2, CLEC4D, LMNB1, PRRG4, TNFAIP6 and VNN1) in CRC (N = 99) and Controls (N = 101) as shown in Raw Ct-values. (Error bars denote Standard Errors of the Mean) All six biomarkers are shown as up-regulated genes in CRC as compared with controls.
Figure 2Comparison of the Expression of Partner or Reference Gene (IL2RB) for the corresponding six biomarkers (numbered from 1 to 6) in CRC (N = 99) and Controls (N = 101). The figure shows the reference gene as down-regulated as compared with control samples.
Expression of Gene Biomarkers in North American and Malaysian Samples
| Symbol | Parameter | ANXA3 | CLEC4D | LMNB1 | PRRG4 | TNFAIP6 | VNN1 |
|---|---|---|---|---|---|---|---|
| North | Fold Change | 1.71 | 1.50 | 1.37 | 1.72 | 1.58 | 1.53 |
| American | p-Value | < 0.0001 | < 0.0001 | < 0.0001 | < 0.0001 | < 0.0001 | < 0.0001 |
| Malaysian | Fold Change | 2.06 | 1.75 | 1.65 | 1.37 | 1.80 | 1.87 |
| p-Value | < 0.0001 | < 0.0001 | < 0.0001 | < 0.0003 | < 0.0001 | < 0.0001 |
Note: North American Training Set comprises 112 CRC and 120 control samples.
Malaysian Study Set comprises 99 CRC and 111 control samples.
The significance of the fold changes were evaluated using Mann-Whitney independent sample rank sum tests.
Comparison on Logistic Regression Analyses between North American and Malaysian Samples.
| Study Location | North American | Malaysian | |
|---|---|---|---|
| Training Set | Test Set | ||
| Sample Size | 232 | 410 | 210 |
| CRC | 112 | 202 | 99 |
| Control | 120 | 208 | 111 |
| Cut-off Value | P = 0.5 | P = 0.5 | P = 0.5 |
| Area under ROC Curve | 0.80 | 0.80 | 0.76 |
| Significant Level | P < 0.0001 | P < 0.0001 | P < 0.0001 |
| Sensitivity | 82% | 72% | 61% |
| Specificity | 64% | 70% | 77% |
| Accuracy | 73% | 71% | 70% |
Note: The MedCalc software, version 11.3 (Broekstraat 52, Mariakerke, Belgium) was used for the statistical analysis. CI denotes confidence interval.
Figure 3Area Under the Curve (AUC) of the Receiver Operating Characteristic Curve (ROC) Analysis with 95% Confidence Limits (AUC = 0.76 and CI: 0.70 - 0.82) and at the Optimized Thresholds (P = 0.4327) for Sensitivity and Specificity. Note: The MedCalc software, version 11.3 (Broekstraat 52, Mariakerke, Belgium) was used for the statistical analysis. CI denotes confidence interval.
Figure 4Area Under the Curve (AUC) of the Receiver Operating Characteristic (ROC) Analysis Based on 1000X 2-Fold Cross Validation (99 CRC and 111 Control Samples). This chart displays the distribution for 1000 iterations of 2-Fold cross-validation using 1000 sets of randomly re-labeled samples generated from 99 CRC and 111 control samples.