Literature DB >> 20839691

The proximal modular neck in THA: a bridge too far: affirms.

Michael J Dunbar1.   

Abstract

Modular necks are a relatively new innovation in total hip arthroplasty (THA), with several companies now offering modular neck options. The proposed advantages of reduced impingement, reduced dislocation rate, and better reconstitution of leg length and offset are compelling. However, few reports in the literature address the outcomes of these devices, and those that are published at best demonstrate equivalence to conventional THA. There are numerous disadvantages to this new technology. Neck dissociation has been reported with a specific design of the modular taper. Numerous case reports exist of the fracture of titanium modular femoral necks, with 1 large series of 5000 cases reporting a fracture rate of 1.4%. Fractures occurred more frequently in heavy men (>100 kg), with the preponderance of fractures occurring around the 2-year mark. Retrieval analysis demonstrates failure of the titanium components at the Morse taper junction of the neck and femoral stem at the point of maximal tension, likely related to notch sensitivity. The additional interface of modular necks in the effective joint space has the potential to generate significant metal ions through a pitting corrosion process. Evidence exists of highly elevated serum cobalt and chromium ions in a modular junction used in large-head THA supporting these concerns. The use of particular neck geometries, such as long retroverted necks, may adversely affect the local biomechanical forces on the femoral component. The proposed mechanism is an increased lever arm leading to increased torque on stair climbing or rising from a chair. Finally, modular necks add significant costs to the implant and the health care system. On balance, based on the literature, the proximal modular neck in THA is a bridge too far. Copyright 2010, SLACK Incorporated.

Entities:  

Mesh:

Year:  2010        PMID: 20839691     DOI: 10.3928/01477447-20100722-30

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  8 in total

1.  Is there material loss at the backside taper in modular CoCr acetabular liners?

Authors:  Matthias T Agne; Richard J Underwood; Sevi B Kocagoz; Daniel W MacDonald; Judd S Day; Javad Parvizi; Matthew J Kraay; Michael A Mont; Gregg R Klein; Harold E Cates; Steven M Kurtz
Journal:  Clin Orthop Relat Res       Date:  2014-10-16       Impact factor: 4.176

2.  Proximal component modularity in THA--at what cost? An implant retrieval study.

Authors:  A M Kop; C Keogh; E Swarts
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

3.  Result of Modular Necks in Primary Total Hip Arthroplasty with a Average Follow-up of Four Years.

Authors:  Jemin Yi; Kye Young Han; Young Jun Nam; Keun Woo Kim
Journal:  Hip Pelvis       Date:  2016-09-30

4.  Traumatic Stem Fractures in Short Stem THA-A Rare Case Series.

Authors:  Carl Haasper; Daniel O Kendoff; Matthias Gebauer; Akos Zahar; Thomas Kreibich; Eduardo M Suero; Thorsten Gehrke
Journal:  HSS J       Date:  2012-04-27

5.  Effect of changing femoral head diameter on bony and prosthetic jumping angles.

Authors:  Takaaki Ohmori; Tamon Kabata; Yoshitomo Kajino; Daisuke Inoue; Tadashi Taga; Takashi Yamamoto; Tomoharu Takagi; Junya Yoshitani; Takuro Ueno; Ken Ueoka; Hiroyuki Tsuchiya
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-10-30

6.  Late Nontraumatic Dissociation of the Femoral Head and Trunnion in a Total Hip Arthroplasty.

Authors:  Simon J M Parker; Wasim Khan; Simon Mellor
Journal:  Case Rep Orthop       Date:  2015-05-11

7.  The histological and elemental characterisation of corrosion particles from taper junctions.

Authors:  S Munir; R A Oliver; B Zicat; W L Walter; W K Walter; W R Walsh
Journal:  Bone Joint Res       Date:  2016-09       Impact factor: 5.853

8.  Does Choice of Head Size and Neck Geometry Affect Stem Migration in Modular Large-Diameter Metal-on-Metal Total Hip Arthroplasty? A Preliminary Analysis.

Authors:  Cs Georgiou; Kg Evangelou; Eg Theodorou; Cg Provatidis; Pd Megas
Journal:  Open Orthop J       Date:  2012-12-14
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.