Literature DB >> 20835764

Impact of PVCs noted during coronary calcium scan on image quality and accuracy in subsequent coronary dual-source CT angiography.

Wolfgang Eicher1, Thomas Kau, Martin Niedermayer, Birgit Senft, Maria Sinzig, Birgit Strozyk, Klaus Armin Hausegger.   

Abstract

The purpose of this study was to investigate the impact of the presence of one or more premature ventricular contractions (PVCs) during coronary calcium score scan (CS) on image quality and accuracy of subsequent dual-source coronary CT angiography (DS CCTA). Fifty-three out of 502 patients showed one or more PVCs during CS and built the study group. Sixty consecutively registered patients with sinus rhythm formed the control group. Two independent, blinded readers classified 1,723 coronary artery segments as being of diagnostic or non-diagnostic image quality. All segments with diagnostic image quality were assessed for the presence for significant coronary artery stenosis. Accuracy was calculated using conventional angiography as standard of reference. The percentage of DS CCTA data sets with diagnostic image quality was significantly lower in the study group (79.2%) compared to the control group (90.6%, P < 0.05). The rate of coronary segment with diagnostic image quality was highly significant lower in the study group (89.5%; n = 723/808) compared to the control group (99.4%; n = 908/915; P < 0.001). However, accuracy did not differ in both groups. Significant correlation between non-diagnostic image quality and mean HR was only found in the study group (P = 0.019). The presence of one or more PVCs during CS does not affect accuracy but impairs image quality of subsequent DS CCTA. Mean HR is a predictor of non-diagnostic data sets only in the study group, suggesting more aggressive HR control could be beneficial.

Entities:  

Mesh:

Year:  2010        PMID: 20835764     DOI: 10.1007/s10554-010-9699-8

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  29 in total

1.  Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed.

Authors:  Bernd J Wintersperger; Konstantin Nikolaou; Franz von Ziegler; Thorsten Johnson; Carsten Rist; Alexander Leber; Thomas Flohr; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Invest Radiol       Date:  2006-05       Impact factor: 6.016

2.  A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association.

Authors:  W G Austen; J E Edwards; R L Frye; G G Gensini; V L Gott; L S Griffith; D C McGoon; M L Murphy; B B Roe
Journal:  Circulation       Date:  1975-04       Impact factor: 29.690

Review 3.  Computed tomography coronary angiography.

Authors:  Stephan Achenbach
Journal:  J Am Coll Cardiol       Date:  2006-11-01       Impact factor: 24.094

4.  Fundamentals of electrocardiography interpretation.

Authors:  Daniel E Becker
Journal:  Anesth Prog       Date:  2006

5.  Contrast-enhanced coronary artery visualization by dual-source computed tomography--initial experience.

Authors:  Stephan Achenbach; Dieter Ropers; Axel Kuettner; Thomas Flohr; Bernd Ohnesorge; Herbert Bruder; Heike Theessen; Meri Karakaya; Werner G Daniel; Werner Bautz; Willi A Kalender; Katharina Anders
Journal:  Eur J Radiol       Date:  2006-01-19       Impact factor: 3.528

6.  Dual-source CT coronary angiography: image quality, mean heart rate, and heart rate variability.

Authors:  David Matt; Hans Scheffel; Sebastian Leschka; Thomas G Flohr; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  AJR Am J Roentgenol       Date:  2007-09       Impact factor: 3.959

7.  Quantification of coronary artery calcium using ultrafast computed tomography.

Authors:  A S Agatston; W R Janowitz; F J Hildner; N R Zusmer; M Viamonte; R Detrano
Journal:  J Am Coll Cardiol       Date:  1990-03-15       Impact factor: 24.094

8.  An application of hierarchical kappa-type statistics in the assessment of majority agreement among multiple observers.

Authors:  J R Landis; G G Koch
Journal:  Biometrics       Date:  1977-06       Impact factor: 2.571

9.  Image quality and diagnostic accuracy of non-invasive coronary imaging with 16 detector slice spiral computed tomography with 188 ms temporal resolution.

Authors:  A Kuettner; T Beck; T Drosch; K Kettering; M Heuschmid; C Burgstahler; C D Claussen; A F Kopp; S Schroeder
Journal:  Heart       Date:  2005-07       Impact factor: 5.994

10.  Diagnostic value of 64-slice multi-detector row cardiac CTA in symptomatic patients.

Authors:  Georg Mühlenbruch; Tobias Seyfarth; Chee Siong Soo; Namasivayam Pregalathan; Andreas Horst Mahnken
Journal:  Eur Radiol       Date:  2006-09-29       Impact factor: 5.315

View more
  2 in total

1.  Salvage of diagnostic quality of image acquired by low-radiation-dose prospectively ECG-triggered coronary CTA during ventricular trigeminy: A case report of a novel image processing method.

Authors:  Harshna V Vadvala; Karl Sayegh; Matthew Moy; Pedro Vinícius Staziaki; Brian B Ghoshhajra
Journal:  HeartRhythm Case Rep       Date:  2015-09-15

2.  Lidocaine bolus may facilitate computed tomographic coronary angiography in patients with frequent premature ventricular contractions.

Authors:  Jerzy Pręgowski; Jan Jastrzębski; Cezary Kępka; Mariusz Kruk; Marcin Demkow; Lukasz Kalińczuk; Rafał Wolny; Michał Ciszewski; Ilona Michałowska; Adam Witkowski
Journal:  Postepy Kardiol Interwencyjnej       Date:  2013-09-16       Impact factor: 1.426

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.