Literature DB >> 20821237

Evaluation of RAPID(®) 5 Access software for examination of capsule endoscopies and reading of the capsule by an endoscopy nurse.

Akiko Shiotani1, Keisuke Honda, Makiko Kawakami, Takahisa Murao, Hiroshi Matsumoto, Ken-Ichi Tarumi, Hiroaki Kusunoki, Jiro Hata, Ken Haruma.   

Abstract

BACKGROUND: Since capsule endoscopy (CE) is time consuming, one possible cost-effective strategy could be the use of an expert endoscopic assistant and available software to select images. Aims were to examine the clinical utility of RAPID(®) 5 Access software and find the optimum setting mode for reading. We also evaluated whether a nurse could preview the CE video and detect significant lesions accurately.
METHODS: The capsule images in 14 volunteers with known mucosal injury induced by low dose aspirin and in 30 patients who were known to have a variety of significant lesions were selected. Using three setting modes of RAPID(®) 5 Access software, the detection rate and reading time for CE images by two well-trained physicians and one expert nurse were compared.
RESULTS: There was no significant difference in detection rate among the three readers. The detection rate using Quickview RAPID(®) 5 Access was significantly higher than that using RAPID(®) Reader version 4.1. Comparison among the three modes of RAPID(®) 5 Access showed that auto mode as well as displaying a single image at 12 fps was superior in the detection rate of denuded redness, while its reading time was longer compared to the other modes. Some significant lesions were not detected by using Quickview and Quadview modes.
CONCLUSIONS: RAPID(®) 5 Access improves diagnostic yield, reducing reading time; however, it is still unacceptable because of the diagnostic miss rate and may be useful as an ancillary reading tool. Developing further improved software and training expert assistants for reading capsule images are necessary.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20821237     DOI: 10.1007/s00535-010-0312-7

Source DB:  PubMed          Journal:  J Gastroenterol        ISSN: 0944-1174            Impact factor:   7.527


  11 in total

1.  The accuracy of an endoscopy nurse in interpreting capsule endoscopy.

Authors:  Gavin N Levinthal; Carol A Burke; Janice M Santisi
Journal:  Am J Gastroenterol       Date:  2003-12       Impact factor: 10.864

2.  Rapid Access Real-Time device and Rapid Access software: new tools in the armamentarium of capsule endoscopy.

Authors:  Cristiano Spada; Maria Elena Riccioni; Guido Costamagna
Journal:  Expert Rev Med Devices       Date:  2007-07       Impact factor: 3.166

3.  Can we reduce capsule endoscopy reading times?

Authors:  Jessie Westerhof; Jan J Koornstra; Rinse K Weersma
Journal:  Gastrointest Endosc       Date:  2008-11-13       Impact factor: 9.427

4.  Reduction of capsule endoscopy reading times by unsupervised image mining.

Authors:  D K Iakovidis; S Tsevas; A Polydorou
Journal:  Comput Med Imaging Graph       Date:  2009-12-06       Impact factor: 4.790

5.  A meta-analysis of the yield of capsule endoscopy compared to other diagnostic modalities in patients with obscure gastrointestinal bleeding.

Authors:  Stuart L Triester; Jonathan A Leighton; Grigoris I Leontiadis; David E Fleischer; Amy K Hara; Russell I Heigh; Arthur D Shiff; Virender K Sharma
Journal:  Am J Gastroenterol       Date:  2005-11       Impact factor: 10.864

6.  Randomized, double-blind, pilot study of geranylgeranylacetone versus placebo in patients taking low-dose enteric-coated aspirin. Low-dose aspirin-induced small bowel damage.

Authors:  Akiko Shiotani; Ken Haruma; Ryuji Nishi; Minoru Fujita; Tomoari Kamada; Keisuke Honda; Hiroaki Kusunoki; Jiro Hata; David Y Graham
Journal:  Scand J Gastroenterol       Date:  2010-03       Impact factor: 2.423

7.  Capsule endoscopy interpretation by an endoscopy nurse - a comparative trial.

Authors:  A Riphaus; S Richter; M Vonderach; T Wehrmann
Journal:  Z Gastroenterol       Date:  2009-03-11       Impact factor: 2.000

8.  A multicenter randomized comparison of the Endocapsule and the Pillcam SB.

Authors:  David R Cave; David E Fleischer; Jonathan A Leighton; Douglas O Faigel; Russell I Heigh; Virender K Sharma; Christopher J Gostout; Elizabeth Rajan; Klaus Mergener; Anne Foley; Michael Lee; Kanishka Bhattacharya
Journal:  Gastrointest Endosc       Date:  2008-04-14       Impact factor: 9.427

9.  Small-bowel imaging in Crohn's disease: a prospective, blinded, 4-way comparison trial.

Authors:  Craig A Solem; Edward V Loftus; Joel G Fletcher; Todd H Baron; Christopher J Gostout; Bret T Petersen; William J Tremaine; Laurence J Egan; William A Faubion; Kenneth W Schroeder; Darrell S Pardi; Karen A Hanson; Debra A Jewell; John M Barlow; Jeff L Fidler; James E Huprich; C Daniel Johnson; W Scott Harmsen; Alan R Zinsmeister; William J Sandborn
Journal:  Gastrointest Endosc       Date:  2008-06-02       Impact factor: 9.427

10.  Inter-observer variations on interpretation of capsule endoscopies.

Authors:  Larry H Lai; Grace L H Wong; Dorothy K L Chow; James Y W Lau; Joseph J Y Sung; Wai K Leung
Journal:  Eur J Gastroenterol Hepatol       Date:  2006-03       Impact factor: 2.566

View more
  13 in total

1.  Capsule endoscopy: comparison of two different reading modes.

Authors:  Ute Günther; Severin Daum; Martin Zeitz; Christian Bojarski
Journal:  Int J Colorectal Dis       Date:  2011-11-09       Impact factor: 2.571

2.  Efficacy of new playback functions at reducing small-bowel wireless capsule endoscopy reading times.

Authors:  Venkataraman Subramanian; Jayan Mannath; Emmanouil Telakis; Krish Ragunath; Christopher J Hawkey
Journal:  Dig Dis Sci       Date:  2012-02-11       Impact factor: 3.199

Review 3.  Small-bowel capsule endoscopy: a ten-point contemporary review.

Authors:  Anastasios Koulaouzidis; Emanuele Rondonotti; Alexandros Karargyris
Journal:  World J Gastroenterol       Date:  2013-06-28       Impact factor: 5.742

Review 4.  Continuing challenges in the diagnosis and management of obscure gastrointestinal bleeding.

Authors:  Veronica Baptista; Neil Marya; Anupam Singh; Abbas Rupawala; Bilal Gondal; David Cave
Journal:  World J Gastrointest Pathophysiol       Date:  2014-11-15

5.  A critical analysis of the effect of view mode and frame rate on reading time and lesion detection during capsule endoscopy.

Authors:  Masanao Nakamura; Alberto Murino; Aine O'Rourke; Chris Fraser
Journal:  Dig Dis Sci       Date:  2015-01-06       Impact factor: 3.199

Review 6.  What defines quality in small bowel capsule endoscopy.

Authors:  Ioannis V Mitselos; Dimitrios K Christodoulou
Journal:  Ann Transl Med       Date:  2018-07

7.  A rapid and accurate method to detect active small bowel gastrointestinal bleeding on video capsule endoscopy.

Authors:  Adam C Stein; Anoop Appannagari; Ibrahim Habib; Carol E Semrad; David T Rubin
Journal:  Dig Dis Sci       Date:  2014-08-22       Impact factor: 3.199

8.  Systematic review and meta-analysis of the performance of nurses in small bowel capsule endoscopy reading.

Authors:  Diana E Yung; Ignacio Fernandez-Urien; Sarah Douglas; John N Plevris; Reena Sidhu; Mark E McAlindon; Simon Panter; Anastasios Koulaouzidis
Journal:  United European Gastroenterol J       Date:  2017-01-11       Impact factor: 4.623

9.  Evaluation of Performance in Colon Capsule Endoscopy Reading by Endoscopy Nurses.

Authors:  Yukiko Handa; Konosuke Nakaji; Kayo Hyogo; Makiko Kawakami; Tomomi Yamamoto; Akiko Fujiwara; Rika Kanda; Motoyasu Osawa; Osamu Handa; Hiroshi Matsumoto; Eiji Umegaki; Akiko Shiotani
Journal:  Can J Gastroenterol Hepatol       Date:  2021-04-28

10.  Evaluation of performance of the Omni mode for detecting video capsule endoscopy images: A multicenter randomized controlled trial.

Authors:  Naoki Hosoe; Kenji Watanabe; Takako Miyazaki; Masaaki Shimatani; Takahiro Wakamatsu; Kazuichi Okazaki; Motohiro Esaki; Takayuki Matsumoto; Takayuki Abe; Takanori Kanai; Kazuo Ohtsuka; Mamoru Watanabe; Keiichi Ikeda; Hisao Tajiri; Naoki Ohmiya; Masanao Nakamura; Hidemi Goto; Tomoyuki Tsujikawa; Haruhiko Ogata
Journal:  Endosc Int Open       Date:  2016-08-08
View more