Literature DB >> 22065113

Capsule endoscopy: comparison of two different reading modes.

Ute Günther1, Severin Daum, Martin Zeitz, Christian Bojarski.   

Abstract

PURPOSE: Capsule endoscopy (CE) is a very useful tool for the evaluation of the small intestine, but it is time consuming. The aim of this study was to compare evaluation times and detection rates in two different reading modes (single view at a speed of 10 frames per second (fps) and four images simultaneously, i.e., quadview mode at a speed of 20 fps) to find the optimum setting mode for evaluation of CE videos.
METHODS: CE videos of 70 patients performed for different indications (obscure bleeding, n = 50; suspected Crohn's disease, n = 10; and suspected or complicated celiac disease, n = 10) were reviewed by investigators A and B in the two different reading modes.
RESULTS: The mean evaluation time using single view at 10 fps was 22 min (SD ± 9.1 min) and 11.9 min (SD ± 4.8 min) using quadview mode at 20 fps. The detection rates of angiodysplasias, erosions, small ulcers, and small polyps were only discreetly lower using the quadview mode at 20 fps. In Crohn's disease and celiac disease, the essential aspects of inflamed or atrophic mucosa segments were equally detected in both reading modes. In one case of complicated celiac disease with severe erosive jejunitis, a lymphoma-suspect lesion was overlooked in the quadview mode at 20 fps.
CONCLUSIONS: It is often possible to read CE videos in quadview mode at a higher speed with even so a high diagnostic yield in a shortened evaluation time.

Entities:  

Mesh:

Year:  2011        PMID: 22065113     DOI: 10.1007/s00384-011-1347-9

Source DB:  PubMed          Journal:  Int J Colorectal Dis        ISSN: 0179-1958            Impact factor:   2.571


  18 in total

1.  The accuracy of an endoscopy nurse in interpreting capsule endoscopy.

Authors:  Gavin N Levinthal; Carol A Burke; Janice M Santisi
Journal:  Am J Gastroenterol       Date:  2003-12       Impact factor: 10.864

2.  Evaluation of RAPID(®) 5 Access software for examination of capsule endoscopies and reading of the capsule by an endoscopy nurse.

Authors:  Akiko Shiotani; Keisuke Honda; Makiko Kawakami; Takahisa Murao; Hiroshi Matsumoto; Ken-Ichi Tarumi; Hiroaki Kusunoki; Jiro Hata; Ken Haruma
Journal:  J Gastroenterol       Date:  2010-09-07       Impact factor: 7.527

3.  ICCE consensus for capsule retention.

Authors:  D Cave; P Legnani; R de Franchis; B S Lewis
Journal:  Endoscopy       Date:  2005-10       Impact factor: 10.093

4.  ASGE Technology Status Evaluation Report: wireless capsule endoscopy.

Authors:  Daniel S Mishkin; Ram Chuttani; Joseph Croffie; James Disario; Julia Liu; Raj Shah; Lehel Somogyi; William Tierney; Louis M Wong Kee Song; Bret T Petersen
Journal:  Gastrointest Endosc       Date:  2006-04       Impact factor: 9.427

5.  Detection of abnormal lesions recorded by capsule endoscopy. A prospective study comparing endoscopist's and nurse's accuracy.

Authors:  F Bossa; G Cocomazzi; M R Valvano; A Andriulli; V Annese
Journal:  Dig Liver Dis       Date:  2006-06-05       Impact factor: 4.088

6.  Rapid Access Real-Time device and Rapid Access software: new tools in the armamentarium of capsule endoscopy.

Authors:  Cristiano Spada; Maria Elena Riccioni; Guido Costamagna
Journal:  Expert Rev Med Devices       Date:  2007-07       Impact factor: 3.166

Review 7.  Capsule retention: a feared complication of wireless capsule endoscopy.

Authors:  Stefanos Karagiannis; Siegbert Faiss; Christos Mavrogiannis
Journal:  Scand J Gastroenterol       Date:  2009       Impact factor: 2.423

Review 8.  Capsule endoscopy: where are we after 6 years of clinical use?

Authors:  M Pennazio
Journal:  Dig Liver Dis       Date:  2006-10-11       Impact factor: 4.088

9.  Capsule endoscopy interpretation by an endoscopy nurse - a comparative trial.

Authors:  A Riphaus; S Richter; M Vonderach; T Wehrmann
Journal:  Z Gastroenterol       Date:  2009-03-11       Impact factor: 2.000

10.  Capsule endoscopy in patients with suspected Crohn's disease and negative endoscopy.

Authors:  J M Herrerías; A Caunedo; M Rodríguez-Téllez; F Pellicer; J M Herrerías
Journal:  Endoscopy       Date:  2003-07       Impact factor: 10.093

View more
  10 in total

1.  A critical analysis of the effect of view mode and frame rate on reading time and lesion detection during capsule endoscopy.

Authors:  Masanao Nakamura; Alberto Murino; Aine O'Rourke; Chris Fraser
Journal:  Dig Dis Sci       Date:  2015-01-06       Impact factor: 3.199

Review 2.  Software for enhanced video capsule endoscopy: challenges for essential progress.

Authors:  Dimitris K Iakovidis; Anastasios Koulaouzidis
Journal:  Nat Rev Gastroenterol Hepatol       Date:  2015-02-17       Impact factor: 46.802

3.  A Comparison of Visual Recognition of the Laryngopharyngeal Structures Between High and Standard Frame Rate Videos of the Fiberoptic Endoscopic Evaluation of Swallowing.

Authors:  Mehran Alizadeh Aghdam; Makoto Ogawa; Toshihiko Iwahashi; Kiyohito Hosokawa; Chieri Kato; Hidenori Inohara
Journal:  Dysphagia       Date:  2017-04-29       Impact factor: 3.438

Review 4.  What defines quality in small bowel capsule endoscopy.

Authors:  Ioannis V Mitselos; Dimitrios K Christodoulou
Journal:  Ann Transl Med       Date:  2018-07

Review 5.  Capsule endoscopy of the small bowel.

Authors:  Mark E McAlindon; Hey-Long Ching; Diana Yung; Reena Sidhu; Anastasios Koulaouzidis
Journal:  Ann Transl Med       Date:  2016-10

Review 6.  The role of capsule endoscopy in acute gastrointestinal bleeding.

Authors:  Moshe Nadler; Rami Eliakim
Journal:  Therap Adv Gastroenterol       Date:  2014-03       Impact factor: 4.409

Review 7.  Quality Indicators for Small Bowel Capsule Endoscopy.

Authors:  Ki-Nam Shim; Seong Ran Jeon; Hyun Joo Jang; Jinsu Kim; Yun Jeong Lim; Kyeong Ok Kim; Hyun Joo Song; Hyun Seok Lee; Jae Jun Park; Ji Hyun Kim; Jaeyoung Chun; Soo Jung Park; Dong-Hoon Yang; Yang Won Min; Bora Keum; Bo-In Lee
Journal:  Clin Endosc       Date:  2017-03-30

Review 8.  Capsule endoscopy for the diagnosis and follow up of Crohn's disease: a comprehensive review of current status.

Authors:  Michael Dam Jensen; Jacob Broder Brodersen; Jens Kjeldsen
Journal:  Ann Gastroenterol       Date:  2016-12-22

9.  Small bowel capsule endoscopy and treat-to-target in Crohn's disease: A systematic review.

Authors:  Catherine Le Berre; Caroline Trang-Poisson; Arnaud Bourreille
Journal:  World J Gastroenterol       Date:  2019-08-21       Impact factor: 5.742

10.  Does the PillCam SB3 capsule endoscopy system improve image reading efficiency irrespective of experience? A pilot study.

Authors:  Teppei Omori; Toshifumi Hara; Sachiyo Sakasai; Harutaka Kambayashi; Shun Murasugi; Ayumi Ito; Shinichi Nakamura; Katsutoshi Tokushige
Journal:  Endosc Int Open       Date:  2018-05-25
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.