Nationwide survey on the operational status of electron accelerators for radiation therapy in Japan.

Ichiro Yamaguchi1, Shinji Tanaka, Toshioh Fujibuchi, Tetsuo Kida, Hiroaki Nagaoka, Hiroshi Watanabe.   

Abstract

A nationwide survey was conducted on electron accelerators for radiation therapy in Japan for obtaining fundamental data on the actual operational situation of these accelerators. The research subjects were all medical institutions equipped with electron accelerators for radiation therapy (874 accelerators) in Japan. Postcards explaining the purpose and procedure of the survey were sent to each institution. Each institution was requested to download a questionnaire from the website and return it by e-mail. We obtained the following results. Energy: about 90% of the accelerators did not exceed 10 MeV as the permitted maximum energy. Beam intensity: a total of 94% of the accelerators did not exceed 4 Gy/min as the mean exposure dose rate. Beam time: a total of 74% of the accelerators were below half of the permitted maximum beam time. However, 2% of the accelerators exceeded 90% of the permitted maximum time. Cumulative dose: about 10% of institutions obtained permission not to use the maximum beam time, but to use the maximum cumulative dose to secure sufficient beam time. From these results, it became clear that the induced radioactivity based on the maximum beam current and the maximum operating time under an official permit would be overestimated. Therefore, the neutron dose should be assessed by use of a daily operational record, not from an official permit.

Mesh:

Year:  2010        PMID: 20821082     DOI: 10.1007/s12194-010-0083-0

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  8 in total

1.  Dose to radiation therapists from activation at high-energy accelerators used for conventional and intensity-modulated radiation therapy.

Authors:  J Alan Rawlinson; Mohammad K Islam; Duncan M Galbraith
Journal:  Med Phys       Date:  2002-04       Impact factor: 4.071

2.  A model to calculate the induced dose rate around an 18 MV ELEKTA linear accelerator.

Authors:  Bruce Perrin; Anne Walker; Ranald Mackay
Journal:  Phys Med Biol       Date:  2003-03-07       Impact factor: 3.609

3.  Neutron dose calculation at the maze entrance of medical linear accelerator rooms.

Authors:  R C Falcão; A Facure; A X Silva
Journal:  Radiat Prot Dosimetry       Date:  2006-09-27       Impact factor: 0.972

4.  Evaluation of the photoneutron field produced in a medical linear accelerator.

Authors:  H S Kim; Y H Park; B C Koo; J W Kwon; J-S Lee; H S Choi
Journal:  Radiat Prot Dosimetry       Date:  2006-10-30       Impact factor: 0.972

5.  Photonuclear dose calculations for high-energy photon beams from Siemens and Varian linacs.

Authors:  Omar Chibani; Chang-Ming Charlie Ma
Journal:  Med Phys       Date:  2003-08       Impact factor: 4.071

6.  Induced activity in a high-energy linear accelerator.

Authors:  L Ahlgren; L E Olsson
Journal:  Phys Med Biol       Date:  1988-03       Impact factor: 3.609

7.  A radiation safety survey on a Clinac-20 linear accelerator.

Authors:  N L Powell; A Newing; M A Bullen; C Sims; S F Leaton
Journal:  Phys Med Biol       Date:  1987-06       Impact factor: 3.609

8.  Neutron source strength measurements for Varian, Siemens, Elekta, and General Electric linear accelerators.

Authors:  David S Followill; Marilyn S Stovall; Stephen F Kry; Geoffrey S Ibbott
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.