Literature DB >> 20808232

Quantitative volumetric perfusion mapping of the microvasculature using contrast ultrasound.

Steven Feingold1, Ryan Gessner, Ismayil M Guracar, Paul A Dayton.   

Abstract

OBJECTIVES: Contrast-enhanced ultrasound imaging has demonstrated significant potential as a noninvasive technology for monitoring blood flow in the microvasculature. With the application of nondestructive contrast imaging pulse sequences combined with a clearance-refill approach, it is possible to create quantitative time-to-refill maps of tissue correlating to blood perfusion rate. One limitation to standard two-dimensional (2D) perfusion imaging is that the narrow elevational beamwidth of 1- or 1.5-D ultrasound transducers provides information in only a single slice of tissue, and thus it is difficult to image exactly the same plane from study to study. We hypothesize that inhomogeneity in vascularization, such as that common in many types of tumors, makes serial perfusion estimates inconsistent unless the same region can be imaged repeatedly. Our objective was to evaluate error in 2D quantitative perfusion estimation in an in vivo sample volume because of differences in transducer positioning. To mitigate observed errors due to imaging plane misalignment, we propose and demonstrate the application of quantitative 3-dimensional (3D) perfusion imaging. We also evaluate the effect of contrast agent concentration and infusion rate on perfusion estimates.
MATERIALS AND METHODS: Contrast-enhanced destruction-reperfusion imaging was performed using parametric mapping of refill times and custom software for image alignment to compensate for tissue motion. Imaging was performed in rats using a Siemens Sequoia 512 imaging system with a 15L8 transducer. A custom 3D perfusion mapping system was designed by incorporating a computer-controlled positioning system to move the transducer in the elevational direction, and the Sequoia was interfaced to the motion system for timing of the destruction-reperfusion sequence and data acquisition. Perfusion estimates were acquired from rat kidneys as a function of imaging plane and in response to the vasoactive drug dopamine.
RESULTS: Our results indicate that perfusion estimates generated by 2D imaging in the rat kidney have mean standard deviations on the order of 10%, and as high as 22%, because of differences in initial transducer position. This difference was larger than changes in kidney perfusion induced by dopamine. With application of 3D perfusion mapping, repeatability in perfusion estimated in the kidney is reduced to a standard deviation of less than 3%, despite random initial transducer positioning. Varying contrast agent administration rate was also observed to bias measured perfusion time, especially at low concentrations; however, we observed that contrast administration rates between 2.7 × 10(8) and 3.9 × 10(8) bubbles/min provided results that were consistent within 3% for the contrast agent type evaluated.
CONCLUSIONS: Three-dimensional perfusion imaging allows a significant reduction in the error caused by transducer positioning, and significantly improves the reliability of quantitative perfusion time estimates in a rat kidney model. When performing perfusion imaging, it is important to use appropriate and consistent contrast agent infusion rates to avoid bias.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20808232      PMCID: PMC3822908          DOI: 10.1097/RLI.0b013e3181ef0a78

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  19 in total

1.  Threshold of fragmentation for ultrasonic contrast agents.

Authors:  J E Chomas; P Dayton; D May; K Ferrara
Journal:  J Biomed Opt       Date:  2001-04       Impact factor: 3.170

2.  Radiation-force assisted targeting facilitates ultrasonic molecular imaging.

Authors:  Shukui Zhao; Mark Borden; Susannah H Bloch; Dustin Kruse; Katherine W Ferrara; Paul A Dayton
Journal:  Mol Imaging       Date:  2004-07       Impact factor: 4.488

3.  Contrast-enhanced computed tomography and ultrasound for the evaluation of tumor blood flow.

Authors:  Amy R Broumas; Rachel E Pollard; Susannah H Bloch; Erik R Wisner; Stephen Griffey; Katherine W Ferrara
Journal:  Invest Radiol       Date:  2005-03       Impact factor: 6.016

4.  Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion.

Authors:  K Wei; A R Jayaweera; S Firoozan; A Linka; D M Skyba; S Kaul
Journal:  Circulation       Date:  1998-02-10       Impact factor: 29.690

5.  Contrast-assisted destruction-replenishment ultrasound for the assessment of tumor microvasculature in a rat model.

Authors:  Rachel E Pollard; Amy R Sadlowski; Susannah H Bloch; Lesley Murray; Erik R Wisner; Stephen Griffey; Katherine W Ferrara
Journal:  Technol Cancer Res Treat       Date:  2002-12

Review 6.  Cardiovascular and renal actions of dopamine: potential clinical applications.

Authors:  L I Goldberg
Journal:  Pharmacol Rev       Date:  1972-03       Impact factor: 25.468

7.  3D perfusion mapping in post-infarct mice using myocardial contrast echocardiography.

Authors:  Brent A French; Yinbo Li; Alexander L Klibanov; Zequan Yang; John A Hossack
Journal:  Ultrasound Med Biol       Date:  2006-06       Impact factor: 2.998

8.  Improving sensitivity in ultrasound molecular imaging by tailoring contrast agent size distribution: in vivo studies.

Authors:  Jason E Streeter; Ryan Gessner; Iman Miles; Paul A Dayton
Journal:  Mol Imaging       Date:  2010-04       Impact factor: 4.488

9.  Rapid 3-D imaging of contrast flow: application in a perfused kidney phantom.

Authors:  N G Chen; J B Fowlkes; P L Carson; M J Schipper; G L LeCarpentier
Journal:  Ultrasound Med Biol       Date:  2009-04-05       Impact factor: 2.998

10.  Contrast-enhanced US of microcirculation of superficially implanted tumors in rats.

Authors:  James E Chomas; Rachel E Pollard; Amy R Sadlowski; Stephen M Griffey; Erik R Wisner; Katherine W Ferrara
Journal:  Radiology       Date:  2003-10-02       Impact factor: 11.105

View more
  53 in total

1.  Mapping microvasculature with acoustic angiography yields quantifiable differences between healthy and tumor-bearing tissue volumes in a rodent model.

Authors:  Ryan C Gessner; Stephen R Aylward; Paul A Dayton
Journal:  Radiology       Date:  2012-07-06       Impact factor: 11.105

2.  Quantification of Microvascular Tortuosity during Tumor Evolution Using Acoustic Angiography.

Authors:  Sarah E Shelton; Yueh Z Lee; Mike Lee; Emmanuel Cherin; F Stuart Foster; Stephen R Aylward; Paul A Dayton
Journal:  Ultrasound Med Biol       Date:  2015-04-07       Impact factor: 2.998

3.  Functional ultrasound imaging for assessment of extracellular matrix scaffolds used for liver organoid formation.

Authors:  Ryan C Gessner; Ariel D Hanson; Steven Feingold; Avery T Cashion; Ana Corcimaru; Bryant T Wu; Christopher R Mullins; Stephen R Aylward; Lola M Reid; Paul A Dayton
Journal:  Biomaterials       Date:  2013-09-04       Impact factor: 12.479

4.  Molecular Ultrasound Imaging of Tissue Inflammation Using an Animal Model of Acute Kidney Injury.

Authors:  Kenneth Hoyt; Jason M Warram; Dezhi Wang; Sithira Ratnayaka; Amie Traylor; Anupam Agarwal
Journal:  Mol Imaging Biol       Date:  2015-12       Impact factor: 3.488

5.  Correlation of ultrasound contrast agent derived blood flow parameters with immunohistochemical angiogenesis markers in murine xenograft tumor models.

Authors:  John R Eisenbrey; Christian C Wilson; Raymond J Ro; Traci B Fox; Ji-Bin Liu; See-Ying Chiou; Flemming Forsberg
Journal:  Ultrasonics       Date:  2013-04-12       Impact factor: 2.890

6.  Volumetric contrast-enhanced ultrasound imaging of renal perfusion.

Authors:  Marshall Mahoney; Anna Sorace; Jason Warram; Sharon Samuel; Kenneth Hoyt
Journal:  J Ultrasound Med       Date:  2014-08       Impact factor: 2.153

7.  Volumetric contrast-enhanced ultrasound imaging to assess early response to apoptosis-inducing anti-death receptor 5 antibody therapy in a breast cancer animal model.

Authors:  Kenneth Hoyt; Anna Sorace; Reshu Saini
Journal:  J Ultrasound Med       Date:  2012-11       Impact factor: 2.153

8.  Effects of high-fat diet and losartan on renal cortical blood flow using contrast ultrasound imaging.

Authors:  Anne-Emilie Declèves; Joshua J Rychak; Dan J Smith; Kumar Sharma
Journal:  Am J Physiol Renal Physiol       Date:  2013-09-18

9.  Toward ultrasound molecular imaging with phase-change contrast agents: an in vitro proof of principle.

Authors:  Paul S Sheeran; Jason E Streeter; Lee B Mullin; Terry O Matsunaga; Paul A Dayton
Journal:  Ultrasound Med Biol       Date:  2013-02-27       Impact factor: 2.998

10.  Contrast-enhanced ultrasound for evaluation of renal trauma during acute hemorrhagic shock: a canine model.

Authors:  Qian Lin; Faqin Lv; Yukun Luo; Qing Song; Qinghua Xu; Yihua Su; Yu Tang; Jie Tang
Journal:  J Med Ultrason (2001)       Date:  2014-12-19       Impact factor: 1.314

View more