Literature DB >> 19345468

Rapid 3-D imaging of contrast flow: application in a perfused kidney phantom.

N G Chen1, J B Fowlkes, P L Carson, M J Schipper, G L LeCarpentier.   

Abstract

Previous studies indicate imaging of ultrasound contrast in 3-D is potentially superior to 2-D imaging for vascular characterization. A dual-beam, dynamic refill technique, which relies on volumetric contrast clearance and sequential imaging, was used to image a preserved porcine kidney perfused with contrast. A model was developed for the contrast profile across the renal artery to estimate fractional blood volume. This model was used along with refill curve information to measure absolute perfusion within renal cortex for a 100-cm(3) volume. Perfusion measurements from a slice within the volume were also made using a modified interval imaging technique. The measured perfusion using the dual-beam technique was consistent with the perfusion measured using the interval imaging technique (dual-beam values were 1.06 +/- 0.04 x corresponding interval imaging values). These experiments suggest that ultrasound contrast perfusion measurements are independent of the volume of contrast eliminated before refill.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19345468      PMCID: PMC3134266          DOI: 10.1016/j.ultrasmedbio.2008.10.016

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  17 in total

1.  Quantitative vascularity of breast masses by Doppler imaging: regional variations and diagnostic implications.

Authors:  C M Sehgal; P H Arger; S E Rowling; E F Conant; C Reynolds; J A Patton
Journal:  J Ultrasound Med       Date:  2000-07       Impact factor: 2.153

2.  Feasibility of the flash-replenishment concept in renal tissue: which parameters affect the assessment of the contrast replenishment?

Authors:  T Schlosser; C Pohl; C Veltmann; S Lohmaier; J Goenechea; A Ehlgen; J Köster; D Bimmel; S Kuntz-Hehner; H Becher; K Tiemann
Journal:  Ultrasound Med Biol       Date:  2001-07       Impact factor: 2.998

3.  Analysis of refill curve shape in ultrasound contrast agent studies.

Authors:  T C Potdevin; J B Fowlkes; A P Moskalik; P L Carson
Journal:  Med Phys       Date:  2004-03       Impact factor: 4.071

4.  Continuous measurement of porcine renal cortex microcirculation with enhanced thermal diffusion technology.

Authors:  T Kraus; E Klar; B R Osswald; L Fernandes; A Mehrabi; M M Gebhard; C Herfarth
Journal:  J Surg Res       Date:  1996-03       Impact factor: 2.192

5.  Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion.

Authors:  K Wei; A R Jayaweera; S Firoozan; A Linka; D M Skyba; S Kaul
Journal:  Circulation       Date:  1998-02-10       Impact factor: 29.690

6.  Relation of contrast echo intensity and flow velocity to the amplification of contrast opacification produced by intermittent ultrasound transmission.

Authors:  K Ohmori; B Cotter; O L Kwan; K Mizushige; A N DeMaria
Journal:  Am Heart J       Date:  1997-12       Impact factor: 4.749

7.  The 3D and 2D color flow display of breast masses.

Authors:  P L Carson; A P Moskalik; A Govil; M A Roubidoux; J B Fowlkes; D Normolle; D D Adler; J M Rubin; M Helvie
Journal:  Ultrasound Med Biol       Date:  1997       Impact factor: 2.998

Review 8.  Sonographic depiction of microvessel perfusion: principles and potential.

Authors:  Arthur C Fleischer; Kenneth J Niermann; Edwin F Donnelly; Thomas E Yankeelov; Kathryn M Canniff; Dennis E Hallahan; Mace E Rothenberg
Journal:  J Ultrasound Med       Date:  2004-11       Impact factor: 2.153

9.  Quantitative contrast ultrasound analysis of renal perfusion in normal dogs.

Authors:  Kenneth R Waller; Robert T O'Brien; James A Zagzebski
Journal:  Vet Radiol Ultrasound       Date:  2007 Jul-Aug       Impact factor: 1.363

10.  Blood flow quantification with contrast-enhanced US: "entrance in the section" phenomenon--phantom and rabbit study.

Authors:  Olivier Lucidarme; Stephanie Franchi-Abella; Jean-Michel Correas; S Lori Bridal; Erol Kurtisovski; Genevieve Berger
Journal:  Radiology       Date:  2003-06-11       Impact factor: 11.105

View more
  3 in total

1.  Validation of dynamic contrast-enhanced ultrasound in rodent kidneys as an absolute quantitative method for measuring blood perfusion.

Authors:  Paul Kogan; Kennita A Johnson; Steven Feingold; Nicholas Garrett; Ismayil Guracar; William J Arendshorst; Paul A Dayton
Journal:  Ultrasound Med Biol       Date:  2011-06       Impact factor: 2.998

2.  High Resolution Ultrasound Superharmonic Perfusion Imaging: In Vivo Feasibility and Quantification of Dynamic Contrast-Enhanced Acoustic Angiography.

Authors:  Brooks D Lindsey; Sarah E Shelton; K Heath Martin; Kathryn A Ozgun; Juan D Rojas; F Stuart Foster; Paul A Dayton
Journal:  Ann Biomed Eng       Date:  2016-11-10       Impact factor: 3.934

3.  Quantitative volumetric perfusion mapping of the microvasculature using contrast ultrasound.

Authors:  Steven Feingold; Ryan Gessner; Ismayil M Guracar; Paul A Dayton
Journal:  Invest Radiol       Date:  2010-10       Impact factor: 6.016

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.