Literature DB >> 20807845

Radiation dose to the conceptus from multidetector CT during early gestation: a method that allows for variations in maternal body size and conceptus position.

John Damilakis1, Kostas Perisinakis, Antonis Tzedakis, Antonios E Papadakis, Apostolos Karantanas.   

Abstract

PURPOSE: To develop a method for estimating the radiation dose to the conceptus from multidetector computed tomography (CT) of the abdomen and pelvis in pregnant patients during the first 7 weeks of gestation.
MATERIALS AND METHODS: This study was approved by the institutional review board and informed consent was obtained. A CT simulation software package was used to (a) develop voxelized models on the basis of image data from 117 nonpregnant patients who underwent abdominal and pelvic multidetector CT and (b) calculate dose at a position of the uterus assumed to be the position of the conceptus in case of pregnancy during the first 7 weeks of gestation. Regression analysis was carried out to establish the relationship among conceptus dose, patient body size, and distance from the conceptus to the anterior skin surface.
RESULTS: Normalized conceptus doses calculated by using the software package ranged from 0.335 to 0.785 mGy per absorbed dose to air. Conceptus dose showed a significant correlation with maternal body size and conceptus depth (R² = 0.793, P < .001). A multivariable correlation of conceptus dose normalized to the free-in-air CT dose index (CTDI(F)) with conceptus depth and patient perimeter was produced for estimating conceptus dose from abdominal and pelvic multidetector CT. Conceptus dose data provided for a specific scanner can be applied to other scanners by using correction factors based on ratios between the weighted CT dose index and CTDI(F), resulting in inaccuracies in the estimation of conceptus dose of less than 12%.
CONCLUSION: The radiation dose to the conceptus from abdominal and pelvic multidetector CT can be estimated with a method that allows for variations in maternal body size and conceptus position. © RSNA, 2010.

Entities:  

Mesh:

Year:  2010        PMID: 20807845     DOI: 10.1148/radiol.10092397

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  Estimation of the radiation dose in pregnancy: an automated patient-specific model using convolutional neural networks.

Authors:  Tianwu Xie; Habib Zaidi
Journal:  Eur Radiol       Date:  2019-06-21       Impact factor: 5.315

2.  Comparing different methods for estimating radiation dose to the conceptus.

Authors:  X Lopez-Rendon; M S Walgraeve; S Woussen; A Dedulle; G Zhang; H Bosmans; F Zanca
Journal:  Eur Radiol       Date:  2016-05-10       Impact factor: 5.315

3.  SAGES guidelines for the use of laparoscopy during pregnancy.

Authors:  Jonathan P Pearl; Raymond R Price; Allison E Tonkin; William S Richardson; Dimitrios Stefanidis
Journal:  Surg Endosc       Date:  2017-06-22       Impact factor: 4.584

4.  Abdominal CT during pregnancy: a phantom study on the effect of patient centring on conceptus radiation dose and image quality.

Authors:  G Solomou; A E Papadakis; J Damilakis
Journal:  Eur Radiol       Date:  2014-11-28       Impact factor: 5.315

5.  Assessment of CT dose to the fetus and pregnant female patient using patient-specific computational models.

Authors:  Tianwu Xie; Pierre-Alexandre Poletti; Alexandra Platon; Christoph D Becker; Habib Zaidi
Journal:  Eur Radiol       Date:  2017-09-08       Impact factor: 5.315

6.  The presence of contrast agent increases organ radiation dose in contrast-enhanced CT.

Authors:  Mahta Mazloumi; Gert Van Gompel; Veerle Kersemans; Johan de Mey; Nico Buls
Journal:  Eur Radiol       Date:  2021-03-30       Impact factor: 5.315

  6 in total