Literature DB >> 20699208

Adaptive imaging for lesion detection using a zoom-in PET system.

Jian Zhou1, Jinyi Qi.   

Abstract

Positron emission tomography (PET) has become a leading modality in molecular imaging. Demands for further improvements in spatial resolution and sensitivity remain high with growing number of applications. In this paper we present a novel PET system design that integrates a high-resolution depth-of-interaction (DOI) detector into an existing PET system to obtain higher-resolution and higher-sensitivity images in a target region around the face of the high-resolution detector. A unique feature of the proposed PET system is that the high-resolution detector can be adaptively positioned based on the detectability or quantitative accuracy of a feature of interest. This paper focuses on the signal-known-exactly, background-known-exactly (SKE-BKE) detection task. We perform theoretical analysis of lesion detectability using computer observers, and then develop methods that can efficiently calculate the optimal position of the high-resolution detector that maximizes the lesion detectability. We simulated incorporation of a high-resolution DOI detector into the microPET II scanner. Quantitative results verified that the new system has better performance than the microPET II scanner in terms of spatial resolution and lesion detectability, and that the optimal position for lesion detection can be reliably predicted by the proposed method.

Entities:  

Mesh:

Year:  2010        PMID: 20699208      PMCID: PMC3014423          DOI: 10.1109/TMI.2010.2064173

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  27 in total

1.  Theoretical study of lesion detectability of MAP reconstruction using computer observers.

Authors:  J Qi; R H Huesman
Journal:  IEEE Trans Med Imaging       Date:  2001-08       Impact factor: 10.048

2.  MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging.

Authors:  Yuan-Chuan Tai; Arion F Chatziioannou; Yongfeng Yang; Robert W Silverman; Ken Meadors; Stefan Siegel; Danny F Newport; Jennifer R Stickel; Simon R Cherry
Journal:  Phys Med Biol       Date:  2003-06-07       Impact factor: 3.609

3.  High-resolution PET detector design: modelling components of intrinsic spatial resolution.

Authors:  Jennifer R Stickel; Simon R Cherry
Journal:  Phys Med Biol       Date:  2005-01-21       Impact factor: 3.609

4.  Penalized maximum-likelihood image reconstruction for lesion detection.

Authors:  Jinyi Qi; Ronald H Huesman
Journal:  Phys Med Biol       Date:  2006-08-02       Impact factor: 3.609

5.  Virtual-pinhole PET.

Authors:  Yuan-Chuan Tai; Heyu Wu; Debashish Pal; Joseph A O'Sullivan
Journal:  J Nucl Med       Date:  2008-02-20       Impact factor: 10.057

6.  A modified expectation maximization algorithm for penalized likelihood estimation in emission tomography.

Authors:  A R De Pierro
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

7.  Two- and three-dimensional image rotation using the FFT.

Authors:  R W Cox; R Tong
Journal:  IEEE Trans Image Process       Date:  1999       Impact factor: 10.856

8.  A feasibility study of a prototype PET insert device to convert a general-purpose animal PET scanner to higher resolution.

Authors:  Heyu Wu; Debashish Pal; Joseph A O'Sullivan; Yuan-Chuan Tai
Journal:  J Nucl Med       Date:  2007-12-12       Impact factor: 10.057

9.  Addition of a channel mechanism to the ideal-observer model.

Authors:  K J Myers; H H Barrett
Journal:  J Opt Soc Am A       Date:  1987-12       Impact factor: 2.129

10.  Micro insert: a prototype full-ring PET device for improving the image resolution of a small-animal PET scanner.

Authors:  Heyu Wu; Debashish Pal; Tae Yong Song; Joseph A O'Sullivan; Yuan-Chuan Tai
Journal:  J Nucl Med       Date:  2008-09-15       Impact factor: 10.057

View more
  9 in total

1.  A generalized reconstruction framework for unconventional PET systems.

Authors:  Aswin John Mathews; Ke Li; Sergey Komarov; Qiang Wang; Bosky Ravindranath; Joseph A O'Sullivan; Yuan-Chuan Tai
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

2.  Improving PET imaging for breast cancer using virtual pinhole PET half-ring insert.

Authors:  Aswin John Mathews; Sergey Komarov; Heyu Wu; Joseph A O'Sullivan; Yuan-Chuan Tai
Journal:  Phys Med Biol       Date:  2013-09-02       Impact factor: 3.609

3.  LOR-interleaving image reconstruction for PET imaging with fractional-crystal collimation.

Authors:  Yusheng Li; Samuel Matej; Joel S Karp; Scott D Metzler
Journal:  Phys Med Biol       Date:  2015-01-02       Impact factor: 3.609

4.  Image reconstruction and system modeling techniques for virtual-pinhole PET insert systems.

Authors:  Daniel B Keesing; Aswin Mathews; Sergey Komarov; Heyu Wu; Tae Yong Song; Joseph A O'Sullivan; Yuan-Chuan Tai
Journal:  Phys Med Biol       Date:  2012-04-11       Impact factor: 3.609

5.  System resolution versus image uncertainty for positron emission tomography scanners.

Authors:  Andrej Studen; Neal Clinthorne
Journal:  J Med Imaging (Bellingham)       Date:  2022-05-13

6.  A high-resolution PET demonstrator using a silicon "magnifying glass".

Authors:  Neal Clinthorne; Eric Cochran; Enrico Chesi; Milan Grkovski; Borut Grošičar; Klaus Honscheid; Sam S Huh; Harris Kagan; Carlos Lacasta; Karol Brzezinski; Vladimir Linhart; Marko Mikuž; D Shane Smith; Vera Stankova; Andrej Studen; Peter Weilhammer; Dejan Žontar
Journal:  Phys Procedia       Date:  2012-10-02

Review 7.  Positron Emission Tomography: Current Challenges and Opportunities for Technological Advances in Clinical and Preclinical Imaging Systems.

Authors:  Juan José Vaquero; Paul Kinahan
Journal:  Annu Rev Biomed Eng       Date:  2015       Impact factor: 9.590

8.  Augmented Whole-Body Scanning via Magnifying PET.

Authors:  Jianyong Jiang; Suranjana Samanta; Ke Li; Stefan B Siegel; Robert A Mintzer; Sanghee Cho; Maurizio Conti; Matthias Schmand; Joseph O'Sullivan; Yuan-Chuan Tai
Journal:  IEEE Trans Med Imaging       Date:  2020-10-28       Impact factor: 10.048

Review 9.  Quantitative statistical methods for image quality assessment.

Authors:  Joyita Dutta; Sangtae Ahn; Quanzheng Li
Journal:  Theranostics       Date:  2013-10-04       Impact factor: 11.556

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.