Literature DB >> 20668342

Variance reduction techniques for fast Monte Carlo CBCT scatter correction calculations.

Ernesto Mainegra-Hing1, Iwan Kawrakow.   

Abstract

Several variance reduction techniques improving the efficiency of the Monte Carlo estimation of the scatter contribution to a cone beam computed tomography (CBCT) scan were implemented in egs_ctct, an EGSnrc-based application for CBCT-related calculations. The largest impact on the efficiency comes from the splitting + Russian Roulette techniques which are described in detail. The fixed splitting technique is outperformed by both the position-dependent importance splitting (PDIS) and the region-dependent importance splitting (RDIS). The superiority of PDIS over RDIS observed for a water phantom with bone inserts is not observed when applying these techniques to a more realistic human chest phantom. A maximum efficiency improvement of several orders of magnitude over an analog calculation is obtained. A scatter calculation combining the reported efficiency gain with a smoothing algorithm is already in the proximity of being of practical use if a medium size computer cluster is available.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20668342     DOI: 10.1088/0031-9155/55/16/S05

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

1.  A GPU tool for efficient, accurate, and realistic simulation of cone beam CT projections.

Authors:  Xun Jia; Hao Yan; Laura Cervino; Michael Folkerts; Steve B Jiang
Journal:  Med Phys       Date:  2012-12       Impact factor: 4.071

2.  Monte Carlo study of the effects of system geometry and antiscatter grids on cone-beam CT scatter distributions.

Authors:  A Sisniega; W Zbijewski; A Badal; I S Kyprianou; J W Stayman; J J Vaquero; J H Siewerdsen
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

3.  A model-based scatter artifacts correction for cone beam CT.

Authors:  Wei Zhao; Don Vernekohl; Jun Zhu; Luyao Wang; Lei Xing
Journal:  Med Phys       Date:  2016-04       Impact factor: 4.071

4.  Metropolis Monte Carlo simulation scheme for fast scattered X-ray photon calculation in CT.

Authors:  Yuan Xu; Yusi Chen; Zhen Tian; Xun Jia; Linghong Zhou
Journal:  Opt Express       Date:  2019-01-21       Impact factor: 3.894

5.  A practical cone-beam CT scatter correction method with optimized Monte Carlo simulations for image-guided radiation therapy.

Authors:  Yuan Xu; Ti Bai; Hao Yan; Luo Ouyang; Arnold Pompos; Jing Wang; Linghong Zhou; Steve B Jiang; Xun Jia
Journal:  Phys Med Biol       Date:  2015-04-10       Impact factor: 3.609

Review 6.  Adaptive proton therapy.

Authors:  Harald Paganetti; Pablo Botas; Gregory C Sharp; Brian Winey
Journal:  Phys Med Biol       Date:  2021-11-15       Impact factor: 3.609

Review 7.  Modelling the physics in the iterative reconstruction for transmission computed tomography.

Authors:  Johan Nuyts; Bruno De Man; Jeffrey A Fessler; Wojciech Zbijewski; Freek J Beekman
Journal:  Phys Med Biol       Date:  2013-06-05       Impact factor: 3.609

8.  Set-up error validation with EPID images: Measurements vs Egs_cbct simulation.

Authors:  D van Eeden; F H J O'Reilly; F C P du Plessis
Journal:  Rep Pract Oncol Radiother       Date:  2019-10-21

9.  Image-based shading correction for narrow-FOV truncated pelvic CBCT with deep convolutional neural networks and transfer learning.

Authors:  Matteo Rossi; Gabriele Belotti; Chiara Paganelli; Andrea Pella; Amelia Barcellini; Pietro Cerveri; Guido Baroni
Journal:  Med Phys       Date:  2021-10-26       Impact factor: 4.506

10.  Implementation of an efficient Monte Carlo calculation for CBCT scatter correction: phantom study.

Authors:  Peter G F Watson; Ernesto Mainegra-Hing; Nada Tomic; Jan Seuntjens
Journal:  J Appl Clin Med Phys       Date:  2015-07-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.