Literature DB >> 20665797

A technique for rapid single-echo spin-echo T2 mapping.

Marshall S Sussman1, Logi Vidarsson, John M Pauly, Hai-Ling Margaret Cheng.   

Abstract

A rapid technique for mapping of T(2) relaxation times is presented. The method is based on the conventional single-echo spin echo approach but uses a much shorter pulse repetition time to accelerate data acquisition. The premise of the new method is the use of a constant difference between the echo time and pulse repetition time, which removes the conventional and restrictive requirement of pulse repetition time >> T(1). Theoretical and simulation investigations were performed to evaluate the criteria for accurate T(2) measurements. Measured T(2)s were shown to be within 1% error as long as the key criterion of pulse repetition time/T(2) > or =3 is met. Strictly, a second condition of echo time/T(1) << 1 is also required. However, violations of this condition were found to have minimal impact in most clinical scenarios. Validation was conducted in phantoms and in vivo T(2) mapping of healthy cartilage and brain. The proposed method offers all the advantages of single-echo spin echo imaging (e.g., immunity to stimulated echo effects, robustness to static field inhomogeneity, flexibility in the number and choice of echo times) in a considerably reduced amount of time and is readily implemented on any clinical scanner.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20665797     DOI: 10.1002/mrm.22454

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  9 in total

1.  Direct visualization of anatomic subfields within the superior aspect of the human lateral thalamus by MRI at 7T.

Authors:  M Kanowski; J Voges; L Buentjen; J Stadler; H-J Heinze; C Tempelmann
Journal:  AJNR Am J Neuroradiol       Date:  2014-05-22       Impact factor: 3.825

2.  Rapid T2 mapping of mouse heart using the carr-purcell-meiboom-gill sequence and compressed sensing reconstruction.

Authors:  Yong Chen; Wen Li; Kai Jiang; Charlie Y Wang; Xin Yu
Journal:  J Magn Reson Imaging       Date:  2016-02-08       Impact factor: 4.813

3.  Simultaneous measurement of T2 and apparent diffusion coefficient (T2 +ADC) in the heart with motion-compensated spin echo diffusion-weighted imaging.

Authors:  Eric Aliotta; Kévin Moulin; Zhaohuan Zhang; Daniel B Ennis
Journal:  Magn Reson Med       Date:  2017-05-17       Impact factor: 4.668

4.  Efficient T2 mapping with blip-up/down EPI and gSlider-SMS (T2 -BUDA-gSlider).

Authors:  Xiaozhi Cao; Kang Wang; Congyu Liao; Zijing Zhang; Siddharth Srinivasan Iyer; Zhifeng Chen; Wei-Ching Lo; Huafeng Liu; Hongjian He; Kawin Setsompop; Jianhui Zhong; Berkin Bilgic
Journal:  Magn Reson Med       Date:  2021-05-28       Impact factor: 3.737

5.  T2 Mapping with and without Fat-Suppression to Predict Treatment Response to Intravenous Glucocorticoid Therapy for Thyroid-Associated Ophthalmopathy.

Authors:  Linhan Zhai; Qiuxia Wang; Ping Liu; Ban Luo; Gang Yuan; Jing Zhang
Journal:  Korean J Radiol       Date:  2022-04-26       Impact factor: 7.109

6.  New rapid, accurate T2 quantification detects pathology in normal-appearing brain regions of relapsing-remitting MS patients.

Authors:  Timothy M Shepherd; Ivan I Kirov; Erik Charlson; Mary Bruno; James Babb; Daniel K Sodickson; Noam Ben-Eliezer
Journal:  Neuroimage Clin       Date:  2017-02-03       Impact factor: 4.881

7.  Improving the Detection of Cholangiocarcinoma: In vitro MRI-Based Study Using Local Coils and T2 Mapping.

Authors:  Narong Khuntikeo; Attapol Titapun; Nittaya Chamadol; Wuttisak Boonphongsathien; Prakasit Sa-Ngiamwibool; Simon D Taylor-Robinson; Christopher A Wadsworth; Shuo Zhang; Evdokia M Kardoulaki; Ian R Young; Richard R A Syms
Journal:  Hepat Med       Date:  2020-03-24

8.  A New Method for Cartilage Evaluation in Femoroacetabular Impingement Using Quantitative T2 Magnetic Resonance Imaging: Preliminary Validation against Arthroscopic Findings.

Authors:  Noam Ben-Eliezer; José G Raya; James S Babb; Thomas Youm; Daniel K Sodickson; Riccardo Lattanzi
Journal:  Cartilage       Date:  2019-08-27       Impact factor: 3.117

9.  Improving the Accuracy, Quality, and Signal-To-Noise Ratio of MRI Parametric Mapping Using Rician Bias Correction and Parametric-Contrast-Matched Principal Component Analysis (PCM-PCA).

Authors:  Christa M Sonderer; Nan-Kuei Chen
Journal:  Yale J Biol Med       Date:  2018-09-21
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.