Literature DB >> 20663465

Influence of oral antidiabetic drugs on hyperglycemic response to foods in persons with type 2 diabetes mellitus as assessed by continuous glucose monitoring system: a pilot study.

Peterson Karolina1, Rudolf Chlup, Zapletalova Jana, Klaus Dieter Kohnert, Pavla Kudlova, Josef Bartek, Marie Nakladalova, Blanka Doubravova, Pavel Seckar.   

Abstract

BACKGROUND: The purpose of this prospective open-label trial was (1) to assess the influence of oral antidiabetic drugs (OAD) on the glycemic index (GI), glucose response curves (GRCs), daily mean plasma glucose (MPG) and (2) to compare the GI of foods in persons with OAD-treated type 2 diabetes mellitus (T2DM) with the respective GI in healthy persons (HP).
METHODS: Tested foods containing 50 g of carbohydrates were eaten for breakfast and dinner after 10 and 4 h of fasting, respectively. Glycemic index, GRC, and MPG were obtained using the CGMS System Gold (CGMS). In T2DM patients [n = 16; age (mean +/- standard error) 56.0 +/- 2.25 years], foods were tested four times: tests 1, 2, and 3 were performed within one week in which placebo was introduced on day 2, and test 4 was carried out five weeks after reintroduction of OAD. Glycemic indexes, GRC, and MPG from tests 1, 2, 3, and 4 were compared. In a control group of 20 HP (age 24.4 +/- 0.71 years), the mean GIs were calculated as the mean from 20 subject-related GIs.
RESULTS: In T2DM patients, subject-related assessment of GIs, GRC, and MPG distinguished persons with and without OAD effect. Nevertheless, the group-related GIs and the MPG on days 2, 8, and 39 showed no significant difference. There was no significant difference between the GIs in OAD-treated T2DM patients (test 4) versus HP (except in apple baby food). Glucose response curves were significantly larger in T2DM patients (test 4) versus HP.
CONCLUSIONS: Determination of GRC and subject-related GI using the CGMS appears to be a potential means for the evaluation of efficacy of OAD treatment. Further studies are underway. 2010 Diabetes Technology Society.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20663465      PMCID: PMC2909533          DOI: 10.1177/193229681000400430

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  40 in total

1.  Low-glycemic index diets in the management of diabetes: a meta-analysis of randomized controlled trials.

Authors:  Jennie Brand-Miller; Susan Hayne; Peter Petocz; Stephen Colagiuri
Journal:  Diabetes Care       Date:  2003-08       Impact factor: 19.112

Review 2.  Role of low-glycemic-index foods in improving overall glycemic control in type 1 and type 2 diabetic patients and correcting excessive postprandial hyperglycemia.

Authors:  G Slama; F Elgrably; M Kabir; S W Rizkalla
Journal:  Horm Metab Res       Date:  2006-07       Impact factor: 2.936

Review 3.  The glycemic index: methodology and clinical implications.

Authors:  T M Wolever; D J Jenkins; A L Jenkins; R G Josse
Journal:  Am J Clin Nutr       Date:  1991-11       Impact factor: 7.045

4.  Carbohydrates in human nutrition. Report of a Joint FAO/WHO Expert Consultation.

Authors: 
Journal:  FAO Food Nutr Pap       Date:  1998

5.  Automated computation of glycemic index for foodstuffs using continuous glucose monitoring.

Authors:  Rudolf Chlup; Pavel Seckar; Jana Zapletalová; Katerina Langová; Pavla Kudlová; Karolina Chlupová; Josef Bartek; Daniela Jelenová
Journal:  J Diabetes Sci Technol       Date:  2008-01

6.  Results of selfmonitoring on glucometer systems Advance and Optium in daily routine.

Authors:  Rudolf Chlup; Martin Payne; Jana Zapletalová; Stanislav Komenda; Blanka Doubravová; Martina Reznícková; Ludmila Chlupová; Pavel Seckar
Journal:  Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub       Date:  2005-06       Impact factor: 1.245

7.  The effect of high- and low-glycemic index energy restricted diets on plasma lipid and glucose profiles in type 2 diabetic subjects with varying glycemic control.

Authors:  Leonie K Heilbronn; Manny Noakes; Peter M Clifton
Journal:  J Am Coll Nutr       Date:  2002-04       Impact factor: 3.169

8.  A Continuous Glucose Monitoring System (CGMS) - a promising approach for improving metabolic control in persons with type 1 Diabetes mellitus treated by insulin pumps.

Authors:  Petr Mlcák; Jana Fialová; Katerina Trnková; Rudolf Chlup
Journal:  Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub       Date:  2004-07       Impact factor: 1.245

9.  Extended prandial glycemic profiles of foods as assessed using continuous glucose monitoring enhance the power of the 120-minute glycemic index.

Authors:  Rudolf Chlup; Karolina Peterson; Jana Zapletalová; Pavla Kudlová; Pavel Seckar
Journal:  J Diabetes Sci Technol       Date:  2010-05-01

10.  Food processing and the glycemic index.

Authors:  J C Brand; P L Nicholson; A W Thorburn; A S Truswell
Journal:  Am J Clin Nutr       Date:  1985-12       Impact factor: 7.045

View more
  2 in total

Review 1.  Utility of different glycemic control metrics for optimizing management of diabetes.

Authors:  Klaus-Dieter Kohnert; Peter Heinke; Lutz Vogt; Eckhard Salzsieder
Journal:  World J Diabetes       Date:  2015-02-15

2.  Glycemic index, glycemic load, and glycemic response to pomelo in patients with type 2 diabetes.

Authors:  Shi-Ying Shao; Wei-Jie Xu; Jing Tao; Jian-Hua Zhang; Xin-Rong Zhou; Gang Yuan; Yan Yang; Jing Zhang; Hong-Yan Zhang; Qiang Xu; Xiu-Xin Deng; Shu-Hong Hu; Mu-Xun Zhang; Zhe-Long Liu; Xue-Feng Yu
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2017-10-20
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.