Results of selfmonitoring on glucometer systems Advance and Optium in daily routine.

Rudolf Chlup1, Martin Payne, Jana Zapletalová, Stanislav Komenda, Blanka Doubravová, Martina Reznícková, Ludmila Chlupová, Pavel Seckar.   

Abstract

The aim of this prospective clinical study was to compare the results of B-glucose estimations performed simultaneously on glucometer Advance (with Micro-draw strips) and Optium (G3 strips) by lay healthy volunteers under non-standardized conditions of everyday life, to assess the difficulties dealing with lay-handling of these systems and to demonstrate the possibilities of the software Glucobalance (Hypoguard) and PC-Link (Medisense/Abbott) for the analysis of selfmonitoring. In the course of 5 days, a total of 721 pairs of measurements were carried out on 10 pairs of glucometer Advance and Optium by 10 healthy volunteers aged 16-40 years. The data transfer of all values into computer from glucometer Advance using the Glucobalance software and from glucometer Optium using the PC-Link was carried out to determine the results. The correlation of B-glucose measured on the glucometer Advance and Optium was strong (r = 0.73). Glucometer Advance brings values about 0.21 +/- 0.06 mmol/l lower than glucometer Optium. The average difference found within each pairs of glucometers Advance - Optium varied. Nevertheless, these differences are acceptable for routine selfmonitoring. The handling of glucometer Advance is not difficult for lay persons. The Glucobalance software simplifies the result evaluation by each tested person. Even though there are some advantages in comparison with the PC-Link, it should be further developed.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16170399

Source DB:  PubMed          Journal:  Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub        ISSN: 1213-8118            Impact factor:   1.245


  4 in total

1.  Automated computation of glycemic index for foodstuffs using continuous glucose monitoring.

Authors:  Rudolf Chlup; Pavel Seckar; Jana Zapletalová; Katerina Langová; Pavla Kudlová; Karolina Chlupová; Josef Bartek; Daniela Jelenová
Journal:  J Diabetes Sci Technol       Date:  2008-01

2.  Extended prandial glycemic profiles of foods as assessed using continuous glucose monitoring enhance the power of the 120-minute glycemic index.

Authors:  Rudolf Chlup; Karolina Peterson; Jana Zapletalová; Pavla Kudlová; Pavel Seckar
Journal:  J Diabetes Sci Technol       Date:  2010-05-01

3.  Influence of oral antidiabetic drugs on hyperglycemic response to foods in persons with type 2 diabetes mellitus as assessed by continuous glucose monitoring system: a pilot study.

Authors:  Peterson Karolina; Rudolf Chlup; Zapletalova Jana; Klaus Dieter Kohnert; Pavla Kudlova; Josef Bartek; Marie Nakladalova; Blanka Doubravova; Pavel Seckar
Journal:  J Diabetes Sci Technol       Date:  2010-07-01

4.  Effective assessment of diabetes control using personal glucometers (CONTOURLINK, Bayer, Germany; CALLA, Wellion, Austria; LINUS, Agamatrix, USA).

Authors:  R Chlup; B Doubravova; J Bartek; J Zapletalova; O Krystynik; V Prochazka
Journal:  Dis Markers       Date:  2013       Impact factor: 3.434

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.