Literature DB >> 16038387

Use of a dynamic bubble trap in the arterial line reduces microbubbles during cardiopulmonary bypass and microembolic signals in the middle cerebral artery.

Mathias Perthel1, Samer Kseibi, Andreas Bendisch, Joachim Laas.   

Abstract

Neurological complications remain an important cause of morbidity and mortality of patients following cardiopulmonary bypass (CPB). Microemboli, as well as cerebral hypoperfusion, are the main postulated mechanisms. This study demonstrates that the insertion of a dynamic bubble trap (DBT) into the curcuit reduces microbubbles in the arterial line and microembolic signals (MES) in the middle cerebral arteries (MCAs). We investigated 12 patients during coronary artery bypass grafting (CABG). The DBT was inserted between the arterial filter and the arterial cannula. For detection of microemboli before and after the DBT, a special ultrasound Doppler device was used. MES were detected by transcranial Doppler monitoring in both MCAs of the patients. Microbubbles and MES were counted during bypass. These data were compared to 12 patients who were operated in a previous period without the use of a DBT. There were no significant differences in both groups with respect to gender, age, crossclamp and bypass time and number of anastomoses. In the group without a DBT in the circuit, a mean of 6311 microbubbles per operation could be observed distal to the arterial filter, corresponding to 282 MES. After inclusion of a DBT, we could register, in the second group, 8496 microemboli proximal and 2915 distal of the DBT, corresponding to 89 MES per operation. The reduction rate of microbubbles in the tubing was 65.7%, corresponding to a reduction in MES of about 86.2%. We conclude that the insertion of a DBT in the arterial line of CPB circuit protects the cerebrovascular system from microembolic events, as demonstrated by lower MES counts.

Entities:  

Mesh:

Year:  2005        PMID: 16038387     DOI: 10.1191/0267659105pf813oa

Source DB:  PubMed          Journal:  Perfusion        ISSN: 0267-6591            Impact factor:   1.972


  4 in total

1.  Evaluation of Quadrox-i adult hollow fiber oxygenator with integrated arterial filter.

Authors:  Yulong Guan; Xiaowei Su; Robert McCoach; Robert Wise; Allen Kunselman; Akif Undar
Journal:  J Extra Corpor Technol       Date:  2010-06

2.  [Cognitive deterioration after cardiosurgery].

Authors:  N Schwarz; M Schönburg; S Kastaun; T Gerriets; M Kaps
Journal:  Nervenarzt       Date:  2011-02       Impact factor: 1.214

3.  Post-arterial filter gaseous microemboli activity of five integral cardiotomy reservoirs during venting: an in vitro study.

Authors:  Gerard J Myers; Cheri Voorhees; Rob Haynes; Bob Eke
Journal:  J Extra Corpor Technol       Date:  2009-03

4.  Neuroprotective effects of dynamic bubble trap use in patients undergoing pulmonary endarterectomy: a two-arm randomized controlled trial.

Authors:  Stefan Guth; Martin Juenemann; Jasmin El Shazly; Tibo Gerriets; Juergen Hennig; Marius Butz; Sabrina Kastaun; Christoph B Wiedenroth; Markus Schoenburg; Marc Wollenschlaeger; Georg Bachmann
Journal:  J Thorac Dis       Date:  2021-10       Impact factor: 2.895

  4 in total