Literature DB >> 17084461

Spatiotemporal pH dynamics following insertion of neural microelectrode arrays.

Matthew D Johnson1, Olivia E Kao, Daryl R Kipke.   

Abstract

Insertion trauma is a critical issue when assessing intracortical electrophysiological and neurochemical recordings. Previous reports document a wide variety of insertion techniques with speeds ranging from 10 microm/s to 10 m/s. We hypothesize that insertion speed has an effect on tissue trauma induced by implantation of a neural probe. In order to monitor the neural interface during and after probe insertion, we have developed a silicon-substrate array with hydrous iridium oxide microelectrodes for potentiometric recording of extracellular pH (pH(e)), a measure of brain homeostasis. Microelectrode sites were sensitive to pH in the super-Nernstian range (-85.9 mV/pH unit) and selective over other analytes including ascorbic acid, Na(+), K(+), Ca(2+), and Mg(2+). Following insertion, arrays recorded either triphasic or biphasic pH(e) responses, with a greater degree of prolonged acidosis for insertions at 50 microm/s than at 0.5 mm/s or 1.0 mm/s (p<0.05). Spatiotemporal analysis of the recordings also revealed micro-scale variability in the pH(e) response along the array, even when using the same insertion technique. Implants with more intense acidosis were often associated histologically with blood along the probe tract. The potentiometric microsensor array has implications not only as a useful tool to measure extracellular pH, but also as a feedback tool for delivery of pharmacological agents to treat surgical brain trauma.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17084461     DOI: 10.1016/j.jneumeth.2006.09.023

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  30 in total

1.  Reduction of neurovascular damage resulting from microelectrode insertion into the cerebral cortex using in vivo two-photon mapping.

Authors:  T D Y Kozai; T C Marzullo; F Hooi; N B Langhals; A K Majewska; E B Brown; D R Kipke
Journal:  J Neural Eng       Date:  2010-07-19       Impact factor: 5.379

2.  Using a common average reference to improve cortical neuron recordings from microelectrode arrays.

Authors:  Kip A Ludwig; Rachel M Miriani; Nicholas B Langhals; Michael D Joseph; David J Anderson; Daryl R Kipke
Journal:  J Neurophysiol       Date:  2008-12-24       Impact factor: 2.714

Review 3.  Advanced neurotechnologies for chronic neural interfaces: new horizons and clinical opportunities.

Authors:  Daryl R Kipke; William Shain; György Buzsáki; E Fetz; Jaimie M Henderson; Jamille F Hetke; Gerwin Schalk
Journal:  J Neurosci       Date:  2008-11-12       Impact factor: 6.167

4.  Implantable microelectrode arrays for simultaneous electrophysiological and neurochemical recordings.

Authors:  Matthew D Johnson; Robert K Franklin; Matthew D Gibson; Richard B Brown; Daryl R Kipke
Journal:  J Neurosci Methods       Date:  2008-07-23       Impact factor: 2.390

5.  Characterization of local pH changes in brain using fast-scan cyclic voltammetry with carbon microelectrodes.

Authors:  Pavel Takmakov; Matthew K Zachek; Richard B Keithley; Elizabeth S Bucher; Gregory S McCarty; R Mark Wightman
Journal:  Anal Chem       Date:  2010-11-03       Impact factor: 6.986

Review 6.  Monitoring rapid chemical communication in the brain.

Authors:  Donita L Robinson; Andre Hermans; Andrew T Seipel; R Mark Wightman
Journal:  Chem Rev       Date:  2008-06-25       Impact factor: 60.622

7.  A Materials Roadmap to Functional Neural Interface Design.

Authors:  Steven M Wellman; James R Eles; Kip A Ludwig; John P Seymour; Nicholas J Michelson; William E McFadden; Alberto L Vazquez; Takashi D Y Kozai
Journal:  Adv Funct Mater       Date:  2017-07-19       Impact factor: 18.808

8.  Insertion of linear 8.4 μm diameter 16 channel carbon fiber electrode arrays for single unit recordings.

Authors:  Paras R Patel; Kyounghwan Na; Huanan Zhang; Takashi D Y Kozai; Nicholas A Kotov; Euisik Yoon; Cynthia A Chestek
Journal:  J Neural Eng       Date:  2015-06-02       Impact factor: 5.379

9.  Aptamer-functionalized neural recording electrodes for the direct measurement of cocaine in vivo.

Authors:  I Mitch Taylor; Zhanhong Du; Emma T Bigelow; James R Eles; Anthony R Horner; Kasey A Catt; Stephen G Weber; Brian G Jamieson; X Tracy Cui
Journal:  J Mater Chem B       Date:  2017-03-06       Impact factor: 6.331

10.  Electrochemical sensing via selective surface modification of iridium microelectrodes to create a platinum black interface.

Authors:  Paras R Patel; Matthew D Gibson; Kip A Ludwig; Nicholas B Langhals
Journal:  Int IEEE EMBS Conf Neural Eng       Date:  2013
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.