Literature DB >> 20642386

Toward adaptive stereotactic robotic brachytherapy for prostate cancer: demonstration of an adaptive workflow incorporating inverse planning and an MR stealth robot.

J Adam Cunha1, I-Chow Hsu, Jean Pouliot, Mack Roach Iii, Katsuto Shinohara, John Kurhanewicz, Galen Reed, Dan Stoianovici.   

Abstract

To translate any robot into a clinical environment, it is critical that the robot can seamlessly integrate with all the technology of a modern clinic. MRBot, an MR-stealth brachytherapy delivery device, was used in a closed-bore 3T MRI and a clinical brachytherapy cone beam CT suite. Targets included ceramic dummy seeds, MR-Spectroscopy-sensitive metabolite, and a prostate phantom. Acquired DICOM images were exported to planning software to register the robot coordinates in the imager's frame, contour and verify target locations, create dose plans, and export needle and seed positions to the robot. The coordination of each system element (imaging device, brachytherapy planning system, robot control, robot) was validated with a seed delivery accuracy of within 2 mm in both a phantom and soft tissue. An adaptive workflow was demonstrated by acquiring images after needle insertion and prior to seed deposition. This allows for adjustment if the needle is in the wrong position. Inverse planning (IPSA) was used to generate a seed placement plan and coordinates for ten needles and 29 seeds were transferred to the robot. After every two needles placed, an image was acquired. The placed seeds were identified and validated prior to placing the seeds in the next two needles. The ability to robotically deliver seeds to locations determined by IPSA and the ability of the system to incorporate novel needle patterns were demonstrated. Shown here is the ability to overcome this critical step. An adaptive brachytherapy workflow is demonstrated which integrates a clinical anatomy-based seed location optimization engine and a robotic brachytherapy device. Demonstration of this workflow is a key element of a successful translation to the clinic of the MRI stealth robotic delivery system, MRBot.

Entities:  

Mesh:

Year:  2010        PMID: 20642386      PMCID: PMC3108452          DOI: 10.3109/13645706.2010.497000

Source DB:  PubMed          Journal:  Minim Invasive Ther Allied Technol        ISSN: 1364-5706            Impact factor:   2.442


  32 in total

1.  MRI-guided prostate brachytherapy with single needle method--a planning study.

Authors:  Marion P R Van Gellekom; Marinus A Moerland; Jan J Battermann; Jan J W Lagendijk
Journal:  Radiother Oncol       Date:  2004-06       Impact factor: 6.280

Review 2.  Interventional robotic systems: applications and technology state-of-the-art.

Authors:  Kevin Cleary; Andreas Melzer; Vance Watson; Gernot Kronreif; Dan Stoianovici
Journal:  Minim Invasive Ther Allied Technol       Date:  2006       Impact factor: 2.442

3.  A new robotic needle insertion method to minimise attendant prostate motion.

Authors:  Vera Lagerburg; Marinus A Moerland; Marco van Vulpen; Jan J W Lagendijk
Journal:  Radiother Oncol       Date:  2006-07-25       Impact factor: 6.280

4.  Guideline for the management of clinically localized prostate cancer: 2007 update.

Authors:  Ian Thompson; James Brantley Thrasher; Gunnar Aus; Arthur L Burnett; Edith D Canby-Hagino; Michael S Cookson; Anthony V D'Amico; Roger R Dmochowski; David T Eton; Jeffrey D Forman; S Larry Goldenberg; Javier Hernandez; Celestia S Higano; Stephen R Kraus; Judd W Moul; Catherine M Tangen
Journal:  J Urol       Date:  2007-06       Impact factor: 7.450

5.  Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns.

Authors:  J A M Cunha; I C Hsu; J Pouliot
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

6.  Inverse planning for interstitial gynecologic template brachytherapy: truly anatomy-based planning.

Authors:  Etienne Lessard; I-Chow Hsu; Jean Pouliot
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-11-15       Impact factor: 7.038

7.  12-year outcomes following permanent prostate brachytherapy in patients with clinically localized prostate cancer.

Authors:  Louis Potters; Carol Morgenstern; Emil Calugaru; Paul Fearn; Anup Jassal; Joseph Presser; Edward Mullen
Journal:  J Urol       Date:  2005-05       Impact factor: 7.450

8.  Increasing prostate-specific antigen profile following definitive radiation therapy for localized prostate cancer: clinical observations.

Authors:  W R Lee; G E Hanks; A Hanlon
Journal:  J Clin Oncol       Date:  1997-01       Impact factor: 44.544

9.  Intraoperative adaptive brachytherapy of iodine-125 prostate implants guided by C-arm cone-beam computed tomography-based dosimetry.

Authors:  Hendrik Westendorp; Carel J Hoekstra; Arie van't Riet; André W Minken; Jos J Immerzeel
Journal:  Brachytherapy       Date:  2007 Oct-Dec       Impact factor: 2.362

Review 10.  Complications following permanent prostate brachytherapy.

Authors:  N N Stone; R G Stock
Journal:  Eur Urol       Date:  2002-04       Impact factor: 20.096

View more
  8 in total

Review 1.  Image-guided robotic interventions for prostate cancer.

Authors:  Ashwin N Sridhar; Archie Hughes-Hallett; Erik K Mayer; Philip J Pratt; Philip J Edwards; Guang-Zhong Yang; Ara W Darzi; Justin A Vale
Journal:  Nat Rev Urol       Date:  2013-06-18       Impact factor: 14.432

2.  Smart sensors for maintaining physiologic homeostasis.

Authors:  David C Klonoff
Journal:  J Diabetes Sci Technol       Date:  2011-05-01

Review 3.  Update on prostate brachytherapy: long-term outcomes and treatment-related morbidity.

Authors:  Johnny Kao; Jamie A Cesaretti; Nelson N Stone; Richard G Stock
Journal:  Curr Urol Rep       Date:  2011-06       Impact factor: 3.092

4.  Concepts and Trends n Autonomy for Robot-Assisted Surgery.

Authors:  Paolo Fiorini; Ken Y Goldberg; Yunhui Liu; Russell H Taylor
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2022-06-23       Impact factor: 14.910

5.  Kinematic and mechanical modelling of a novel 4-DOF robotic needle guide for MRI-guided prostate intervention.

Authors:  Pradipta Biswas; Hossein Dehghani; Sakura Sikander; Sang-Eun Song
Journal:  Biomed Eng Adv       Date:  2022-05-24

6.  Feasibility of interstitial stepping-source electronic brachytherapy to locally inoperable tumors.

Authors:  Arne Mathias Ruder; Laurens Inghelram; Frank Schneider; Gustavo R Sarria; Jürgen Hesser; Frederic Bludau; Udo Obertacke; Frederik Wenz; Yasser Abo-Madyan; Frank A Giordano
Journal:  J Contemp Brachytherapy       Date:  2020-10-30

7.  In-bore setup and software for 3T MRI-guided transperineal prostate biopsy.

Authors:  Junichi Tokuda; Kemal Tuncali; Iulian Iordachita; Sang-Eun Song; Andriy Fedorov; Sota Oguro; Andras Lasso; Fiona M Fennessy; Clare M Tempany; Nobuhiko Hata
Journal:  Phys Med Biol       Date:  2012-09-05       Impact factor: 3.609

8.  A novel multi-DoF surgical robotic system for brachytherapy on liver tumor: Design and control.

Authors:  Xiaofeng Lin; Shoujun Zhou; Tiexiang Wen; Shenghao Jiang; Cheng Wang; Jingtao Chen
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-05-01       Impact factor: 2.924

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.