Literature DB >> 20637655

Forces across the middle of the intact clavicle during shoulder motion.

Maria Iannolo1, Frederick W Werner, Levi G Sutton, Sean M Serell, Scott M VanValkenburg.   

Abstract

HYPOTHESIS: The optimal management of displaced middle third clavicle fractures is currently under investigation. Advances in fracture fixation technology have expanded the indications for operative fracture management. Data are currently unavailable regarding the normal forces and moments that occur in the middle clavicle with motion of the glenohumeral joint. This study tested our null hypothesis that active range of motion in internal rotation, external rotation, and abduction would produce a similar magnitude of force across the middle clavicle.
MATERIALS AND METHODS: Clavicle forces were measured in 6 whole fresh frozen cadavers using a 6 degree-of-freedom load cell mounted to the middle third of the clavicle. The rotator cuff tendons were isolated, divided, and connected to a system of weights. The forces across the clavicle in 3 orthogonal directions were quantified during simulated active abduction, internal rotation, and external rotation.
RESULTS: There were statistically greater axial compressive force and torque in the clavicle during humeral abduction compared with internal or external rotation. During external rotation, there were statistically greater tensile forces compared with abduction or internal rotation. There were no statistical differences in the superior-inferior or anterior-posterior forces with the 3 motions studied. DISCUSSION: Overall, active abduction caused the greatest increase in middle clavicle forces and torque. Abduction resulted in the most significant axial compressive force, whereas active external rotation caused the greatest tensile force across the intact middle clavicle.
CONCLUSIONS: To our knowledge, these findings represent the first results describing the forces across the intact clavicle during glenohumeral motion. These data can be used to aid clinicians in treating these fractures, guide the design of future biomechanical studies, and develop rehabilitation protocols.
Copyright © 2010 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20637655     DOI: 10.1016/j.jse.2010.03.016

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  6 in total

1.  Development of the Utrecht Score for clavicle fractures: a short and complete clavicle score with patient-reported and objective measures.

Authors:  Martijn Hulsmans; Steven Ferree; Marijn Houwert; Marcel Dijkgraaf; Egbert Jan Verleisdonk; Mark van Heijl
Journal:  Eur J Trauma Emerg Surg       Date:  2018-08-09       Impact factor: 3.693

2.  Bicortical versus unicortical fixation of plated clavicular fractures: A biomechanical study.

Authors:  Ezequiel E Zaidenberg; Michael Voor; Enrique Pereira; Luciano A Rossi; Carlos R Zaidenberg
Journal:  Shoulder Elbow       Date:  2020-04-23

3.  Biomechanical comparison of the Locking Compression superior anterior clavicle plate with seven and ten hole reconstruction plates in midshaft clavicle fracture stabilisation.

Authors:  Lars Eden; Stefanie Doht; Sönke P Frey; Dirk Ziegler; Jan Stoyhe; Kai Fehske; Torsten Blunk; Rainer H Meffert
Journal:  Int Orthop       Date:  2012-10-17       Impact factor: 3.075

4.  Anteroinferior 2.7-mm versus 3.5-mm plating of the clavicle: A biomechanical study.

Authors:  Nicholas Pulos; Richard S Yoon; Snehal Shetye; Michael W Hast; Frank Liporace; Derek J Donegan
Journal:  Injury       Date:  2016-06-03       Impact factor: 2.586

Review 5.  Axial-Plane Biomechanical Evaluation of 2 Suspensory Cortical Button Fixation Constructs for Acromioclavicular Joint Reconstruction.

Authors:  Steven Struhl; Theodore S Wolfson; Frederick Kummer
Journal:  Orthop J Sports Med       Date:  2016-12-16

6.  A Biomechanical and Clinical Comparison of Midshaft Clavicle Plate Fixation: Are 2 Screws as Good as 3 on Each Side of the Fracture?

Authors:  Christopher G Larsen; Brian Sleasman; Steven C Chudik
Journal:  Orthop J Sports Med       Date:  2017-09-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.