Literature DB >> 20634432

Tetralogy of fallot: 3D velocity-encoded MR imaging for evaluation of right ventricular valve flow and diastolic function in patients after correction.

Annelies E van der Hulst1, Jos J M Westenberg, Lucia J M Kroft, Jeroen J Bax, Nico A Blom, Albert de Roos, Arno A W Roest.   

Abstract

PURPOSE: To evaluate three-dimensional (3D) velocity-encoded (VE) magnetic resonance (MR) imaging, as compared with two-dimensional (2D) VE MR imaging, for assessment of pulmonary valve (PV) and tricuspid valve (TV) flow, with planimetry as the reference standard, and to evaluate diastolic function in patients with a corrected tetralogy of Fallot (TOF).
MATERIALS AND METHODS: Local institutional review board approval was obtained, and patients or their parents gave informed consent. Twenty-five patients with a corrected TOF (12 male, 13 female; mean age, 13.1 years +/- 2.7 [standard deviation]; age range, 8-18 years) and 19 control subjects (12 male, seven female; mean age, 14.1 years +/- 2.4; age range, 8-18 years) underwent planimetric MR imaging, 2D VE MR imaging, and 3D VE MR imaging for TV and PV flow evaluation. For evaluation of diastolic function, PV and TV flow were summated. Data were analyzed by using linear regression analysis, paired and unpaired t testing, and Bland-Altman plots.
RESULTS: Strong correlations between the 2D VE MR and 3D VE MR measurements of PV flow (for forward flow: r = 0.87, P < .01; for backward flow: r = 0.97, P < .01) were observed. With PV effective flow as a reference, 3D TV effective flow measurements were more accurate than 2D TV effective flow measurements: In patients, the mean 2D TV effective flow versus 2D PV effective flow difference was 17.6 mL +/- 11 (P < .001), and the mean 3D TV effective flow versus 3D PV effective flow difference was -1.2 mL +/- 4.7 (P = .22). Diastolic functional impairment in patients could be detected at 3D VE MR imaging diastolic assessment.
CONCLUSION: Three-dimensional VE MR imaging is accurate for PV flow assessment and is more accurate than 2D VE MR imaging for TV flow evaluation. Assessment of diastolic function with 3D VE MR imaging can facilitate ongoing research of diastolic dysfunction in patients with a corrected TOF. (c) RSNA, 2010.

Entities:  

Mesh:

Year:  2010        PMID: 20634432     DOI: 10.1148/radiol.10092269

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  27 in total

1.  Four-dimensional flow MRI for evaluation of post-stenotic turbulent flow in a phantom: comparison with flowmeter and computational fluid dynamics.

Authors:  Jihoon Kweon; Dong Hyun Yang; Guk Bae Kim; Namkug Kim; MunYoung Paek; Aurelien F Stalder; Andreas Greiser; Young-Hak Kim
Journal:  Eur Radiol       Date:  2016-01-08       Impact factor: 5.315

2.  Comparison of 4D flow and 2D velocity-encoded phase contrast MRI sequences for the evaluation of aortic hemodynamics.

Authors:  Emilie Bollache; Pim van Ooij; Alex Powell; James Carr; Michael Markl; Alex J Barker
Journal:  Int J Cardiovasc Imaging       Date:  2016-07-19       Impact factor: 2.357

3.  Evaluation of valvular insufficiency and shunts with parallel-imaging compressed-sensing 4D phase-contrast MR imaging with stereoscopic 3D velocity-fusion volume-rendered visualization.

Authors:  Albert Hsiao; Michael Lustig; Marcus T Alley; Mark J Murphy; Shreyas S Vasanawala
Journal:  Radiology       Date:  2012-08-24       Impact factor: 11.105

4.  Inlet and outlet valve flow and regurgitant volume may be directly and reliably quantified with accelerated, volumetric phase-contrast MRI.

Authors:  Albert Hsiao; Umar Tariq; Marcus T Alley; Michael Lustig; Shreyas S Vasanawala
Journal:  J Magn Reson Imaging       Date:  2014-02-08       Impact factor: 4.813

5.  Improved cardiovascular flow quantification with time-resolved volumetric phase-contrast MRI.

Authors:  Albert Hsiao; Marcus T Alley; Payam Massaband; Robert J Herfkens; Frandics P Chan; Shreyas S Vasanawala
Journal:  Pediatr Radiol       Date:  2011-01-11

Review 6.  Imaging of patients with congenital heart disease.

Authors:  Arno A W Roest; Albert de Roos
Journal:  Nat Rev Cardiol       Date:  2011-11-01       Impact factor: 32.419

7.  Assessment of intracardiac flow and vorticity in the right heart of patients after repair of tetralogy of Fallot by flow-sensitive 4D MRI.

Authors:  Daniel Hirtler; Julio Garcia; Alex J Barker; Julia Geiger
Journal:  Eur Radiol       Date:  2016-01-08       Impact factor: 5.315

Review 8.  4D flow MRI applications in congenital heart disease.

Authors:  Judy Rizk
Journal:  Eur Radiol       Date:  2020-09-01       Impact factor: 5.315

Review 9.  Advanced flow MRI: emerging techniques and applications.

Authors:  M Markl; S Schnell; C Wu; E Bollache; K Jarvis; A J Barker; J D Robinson; C K Rigsby
Journal:  Clin Radiol       Date:  2016-03-02       Impact factor: 2.350

10.  Venous and arterial flow quantification are equally accurate and precise with parallel imaging compressed sensing 4D phase contrast MRI.

Authors:  Umar Tariq; Albert Hsiao; Marcus Alley; Tao Zhang; Michael Lustig; Shreyas S Vasanawala
Journal:  J Magn Reson Imaging       Date:  2012-11-21       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.