| Literature DB >> 20618978 |
Steven McPhail1, Terry Haines.
Abstract
BACKGROUND: Assessments of change in subjective patient reported outcomes such as health-related quality of life (HRQoL) are a key component of many clinical and research evaluations. However, conventional longitudinal evaluation of change may not agree with patient perceived change if patients' understanding of the subjective construct under evaluation changes over time (response shift) or if patients' have inaccurate recollection (recall bias). This study examined whether older adults' perception of change is in agreement with conventional longitudinal evaluation of change in their HRQoL over the duration of their hospital stay. It also investigated this level of agreement after adjusting patient perceived change for recall bias that patients may have experienced.Entities:
Mesh:
Year: 2010 PMID: 20618978 PMCID: PMC2912788 DOI: 10.1186/1477-7525-8-65
Source DB: PubMed Journal: Health Qual Life Outcomes ISSN: 1477-7525 Impact factor: 3.186
Demographic information for participants included in analysis.
| Hospitalised older adults | |
|---|---|
| Datasets complete and included in analysis (% of total) | 101 (98.1%) |
| Length of stay in days - median (IQR) | 38 (20-60) |
| Age - mean (sd) | 73.3 (11.2) |
| Female - number (% of those patients included in analysis) | 48 (47.5%) |
| Baseline health-related quality of life (EQ-5D utility) - mean (sd) | 0.368 (0.338) |
| Baseline health-related quality of life (EQ-5D VAS) - mean (sd) | 63.2 (17.1) |
| Perception of baseline at discharge (EQ-5D utility then test) - mean (sd)* | 0.215 (0.406) |
| Perception of baseline at discharge (EQ-5D VAS then test) - mean (sd)* | 45.7 (21.0) |
| Recall of baseline response (EQ-5D utility recall test) - mean (sd)* | 0.231 (0.405) |
| Recall of baseline response (EQ-5D VAS recall test) - mean (sd)* | 47.5 (20.3) |
| Discharge health-related quality of life (EQ-5D utility) - mean (sd)* | 0.656 (0.240) |
| Discharge health-related quality of life (EQ-5D VAS) - mean (sd)* | 72.5 (16.7) |
* Collected at the discharge assessment
Mean change, intraclass correlation coefficient (ICC), and limits of agreement (LOA) between change scores calculated from conventional longitudinal assessments and the patients' perspective (with and without adjustment for recall bias).
| Measure | Patient perspective adjusted for recall bias | Conventional change | Patient perspective change | ICC | Limits of agreement | p-value* | ||
|---|---|---|---|---|---|---|---|---|
| Lower LOA | Mean difference | Upper LOA | ||||||
| EQ-5D Utility | No | 0.287 | 0.441 | 0.34 | -1.007 | -0.150 | 0.700 | < 0.001* |
| EQ-5D Utility | Yes | 0.287 | 0.303 | 0.98 | -0.150 | -0.016 | 0.118 | 0.019* |
| EQ-5D VAS | No | 9.3 | 26.7 | 0.40 | -60.7 | -17.4 | 25.8 | < 0.001* |
| EQ-5D VAS | Yes | 9.3 | 11.0 | 0.90 | -19.9 | -1.7 | 16.5 | 0.060 |
* A p-value < 0.05 indicates that a systematic difference exists (i.e. change from patient perspective was either consistently higher or consistently lower than conventional change scores.
Figure 1Bland-Altman plots (with limits of agreement) for change calculated from conventional longitudinal assessments and patient perceived change in utility without (1a) and with (1b) adjustment for recall bias as well as for change in EQ-5D VAS without (1c) and with (1d) adjustment for recall bias.
Absolute differences between conventional and patient perceived change (with and without adjustment for recall bias) and the number of patients with this difference greater than a minimal clinically important difference (MCID) in utility of 0.081.
| Utility | VAS | > MCID | |
|---|---|---|---|
| No adjustment for recall bias | 0.363 (0.273) | 22.3 (16.6) | 84 (83.2%) |
| With adjustment for recall bias | 0.021 (0.066) | 3.5 (8.6) | 8 (7.9%) |
Mean change, intraclass correlation coefficient (ICC), and limits of agreement (LOA) between change scores calculated from the patients' perspective with adjustment for recall bias and from the patients' perspective without adjustment for recall bias.
| Measure | Patient perspective of change | ICC | Limits of agreement | p-value* | |||
|---|---|---|---|---|---|---|---|
| With recall bias adjustment | Without recall bias adjustment mean (95% CI) | Lower LOA | Mean difference | Upper LOA | |||
| EQ-5D Utility | 0.303 | 0.441 | 0.36 | -0.979 | -0.138 | 0.704 | 0.002* |
| EQ-5D VAS | 11.0 | 26.7 | 0.50 | -57.1 | -15.7 | 25.7 | < 0.001* |
*A p-value < 0.05 indicates that a systematic difference exists (i.e. patient perspective of change adjusted for recall bias was consistently higher or consistently lower than when no adjustment for recall bias was made.