Literature DB >> 20588526

In vivo investigation of human cone photoreceptors with SLO/OCT in combination with 3D motion correction on a cellular level.

Michael Pircher1, Erich Götzinger, Harald Sattmann, Rainer A Leitgeb, Christoph K Hitzenberger.   

Abstract

We present a further improvement of our SLO/OCT imaging system which enables to practically eliminate all eye motion artifacts with a correction accuracy approaching sub-cellular dimensions. Axial eye tracking is achieved by using a hardware based, high speed tracking system that consists of a rapid scanning optical delay line in the reference arm of the interferometer. A software based algorithm is employed to correct for transverse eye motion in a post-processing step. The instrument operates at a frame rate of 40 en-face fps with a field of view of approximately 1 degrees x 1 degrees. Dynamic focusing enables the recording of 3D volumes of the human retina with cellular resolution throughout the entire imaging depth. Several volumes are stitched together to increase the total field of view. Different features of the three dimensional structure of cone photoreceptors are investigated in detail and at different eccentricities from the fovea.

Entities:  

Mesh:

Year:  2010        PMID: 20588526      PMCID: PMC2976031          DOI: 10.1364/OE.18.013935

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  27 in total

1.  Spectral domain optical coherence tomography: ultra-high speed, ultra-high resolution ophthalmic imaging.

Authors:  Teresa C Chen; Barry Cense; Mark C Pierce; Nader Nassif; B Hyle Park; Seok H Yun; Brian R White; Brett E Bouma; Guillermo J Tearney; Johannes F de Boer
Journal:  Arch Ophthalmol       Date:  2005-12

Review 2.  Recent developments in optical coherence tomography for imaging the retina.

Authors:  Mirjam E J van Velthoven; Dirk J Faber; Frank D Verbraak; Ton G van Leeuwen; Marc D de Smet
Journal:  Prog Retin Eye Res       Date:  2006-12-08       Impact factor: 21.198

3.  Dynamic focus in optical coherence tomography for retinal imaging.

Authors:  M Pircher; E Götzinger; C K Hitzenberger
Journal:  J Biomed Opt       Date:  2006 Sep-Oct       Impact factor: 3.170

4.  High-speed phase- and group-delay scanning with a grating-based phase control delay line.

Authors:  G J Tearney; B E Bouma; J G Fujimoto
Journal:  Opt Lett       Date:  1997-12-01       Impact factor: 3.776

5.  High-speed volumetric imaging of cone photoreceptors with adaptive optics spectral-domain optical coherence tomography.

Authors:  Yan Zhang; Barry Cense; Jungtae Rha; Ravi S Jonnal; Weihua Gao; Robert J Zawadzki; John S Werner; Steve Jones; Scot Olivier; Donald T Miller
Journal:  Opt Express       Date:  2006-05-15       Impact factor: 3.894

Review 6.  Combinations of techniques in imaging the retina with high resolution.

Authors:  Adrian Gh Podoleanu; Richard B Rosen
Journal:  Prog Retin Eye Res       Date:  2008-03-28       Impact factor: 21.198

7.  Supernormal vision and high-resolution retinal imaging through adaptive optics.

Authors:  J Liang; D R Williams; D T Miller
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  1997-11       Impact factor: 2.129

8.  Clinical application of rapid serial fourier-domain optical coherence tomography for macular imaging.

Authors:  Suhail Alam; Robert J Zawadzki; Stacey Choi; Christina Gerth; Susanna S Park; Lawrence Morse; John S Werner
Journal:  Ophthalmology       Date:  2006-06-12       Impact factor: 12.079

Review 9.  State-of-the-art retinal optical coherence tomography.

Authors:  Wolfgang Drexler; James G Fujimoto
Journal:  Prog Retin Eye Res       Date:  2007-08-11       Impact factor: 21.198

10.  Simultaneous SLO/OCT imaging of the human retina with axial eye motion correction.

Authors:  Michael Pircher; Bernhard Baumann; Erich Götzinger; Harald Sattmann; Christoph K Hitzenberger
Journal:  Opt Express       Date:  2007-12-10       Impact factor: 3.894

View more
  28 in total

1.  High-speed adaptive optics for imaging of the living human eye.

Authors:  Yongxin Yu; Tianjiao Zhang; Alexander Meadway; Xiaolin Wang; Yuhua Zhang
Journal:  Opt Express       Date:  2015-09-07       Impact factor: 3.894

2.  Optimization of confocal scanning laser ophthalmoscope design.

Authors:  Francesco LaRocca; Al-Hafeez Dhalla; Michael P Kelly; Sina Farsiu; Joseph A Izatt
Journal:  J Biomed Opt       Date:  2013-07       Impact factor: 3.170

3.  Handheld simultaneous scanning laser ophthalmoscopy and optical coherence tomography system.

Authors:  Francesco Larocca; Derek Nankivil; Sina Farsiu; Joseph A Izatt
Journal:  Biomed Opt Express       Date:  2013-10-01       Impact factor: 3.732

4.  True color scanning laser ophthalmoscopy and optical coherence tomography handheld probe.

Authors:  Francesco LaRocca; Derek Nankivil; Sina Farsiu; Joseph A Izatt
Journal:  Biomed Opt Express       Date:  2014-08-27       Impact factor: 3.732

5.  In vivo imaging of human photoreceptor mosaic with wavefront sensorless adaptive optics optical coherence tomography.

Authors:  Kevin S K Wong; Yifan Jian; Michelle Cua; Stefano Bonora; Robert J Zawadzki; Marinko V Sarunic
Journal:  Biomed Opt Express       Date:  2015-01-16       Impact factor: 3.732

6.  Wavefront sensorless adaptive optics OCT with the DONE algorithm for in vivo human retinal imaging [Invited].

Authors:  Hans R G W Verstraete; Morgan Heisler; Myeong Jin Ju; Daniel Wahl; Laurens Bliek; Jeroen Kalkman; Stefano Bonora; Yifan Jian; Michel Verhaegen; Marinko V Sarunic
Journal:  Biomed Opt Express       Date:  2017-03-21       Impact factor: 3.732

Review 7.  Review of adaptive optics OCT (AO-OCT): principles and applications for retinal imaging [Invited].

Authors:  Michael Pircher; Robert J Zawadzki
Journal:  Biomed Opt Express       Date:  2017-04-19       Impact factor: 3.732

8.  Adaptive optics SLO/OCT for 3D imaging of human photoreceptors in vivo.

Authors:  Franz Felberer; Julia-Sophie Kroisamer; Bernhard Baumann; Stefan Zotter; Ursula Schmidt-Erfurth; Christoph K Hitzenberger; Michael Pircher
Journal:  Biomed Opt Express       Date:  2014-01-10       Impact factor: 3.732

9.  A dual-modal retinal imaging system with adaptive optics.

Authors:  Alexander Meadway; Christopher A Girkin; Yuhua Zhang
Journal:  Opt Express       Date:  2013-12-02       Impact factor: 3.894

10.  Directional sensitivity of the retina: A layered scattering model of outer-segment photoreceptor pigments.

Authors:  Brian Vohnsen
Journal:  Biomed Opt Express       Date:  2014-04-18       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.