Literature DB >> 20585814

Comparison of some physical properties of finger spreaders made of stainless steel or nickel-titanium alloys.

Hélio P Lopes1, Mônica A S Neves, Carlos N Elias, Edson J L Moreira, José F Siqueira.   

Abstract

The purpose of this study was to evaluate the flexibility, shape, and surface finishing of stainless steel (SS) and nickel-titanium (NiTi) finger spreaders as well as to compare the load required to insert these spreaders along a gutta-percha point adapted to the apical segment of curved or straight artificial canals. Instrument flexibility was investigated by using a universal testing machine in the cantilever-flexibility test. Scanning electron microscopy (SEM) was used to examine the shape and surface finishing of different sizes of SS and NiTi finger spreaders. Penetration load was evaluated only for spreaders size C by using the universal testing machine in a compressive test. As for flexibility, the load needed to bend the SS finger spreader sizes A, B, C, and D was approximately 167%, 146%, 102%, and 64% greater than the respective sizes of NiTi finger spreaders. SEM analysis revealed that the instrument tips were always tapered, but with different vertices. NiTi spreaders showed tips with circumferential grooves; whereas, those from SS spreaders exhibited longitudinal grooves. NiTi finger spreaders required a significantly higher penetration load than SS spreaders. This difference was probably related to the different shapes and surface finishing of the instrument tips. Different characteristics of finger spreaders may result in different clinical performance during the lateral compaction technique.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20585814     DOI: 10.1007/s00784-010-0438-2

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  16 in total

1.  Comparison of nickel-titanium and stainless-steel spreader penetration and accessory cone fit in curved canals.

Authors:  K J Schmidt; T L Walker; J D Johnson; B K Nicoll
Journal:  J Endod       Date:  2000-01       Impact factor: 4.171

2.  A comparison of stainless steel and nickel-titanium H-type instruments of identical design: torsional and bending tests.

Authors:  R B Kazemi; E Stenman; L S Spångberg
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2000-10

3.  A comparison of spreader penetration depth and load required during lateral condensation in teeth prepared using various root canal preparation techniques.

Authors:  S F Dulaimi; M K Wali Al-Hashimi
Journal:  Int Endod J       Date:  2005-08       Impact factor: 5.264

4.  Further investigation of spreader loads required to cause vertical root fracture during lateral condensation.

Authors:  J Q Holcomb; D L Pitts; J I Nicholls
Journal:  J Endod       Date:  1987-06       Impact factor: 4.171

5.  The influence of the method of canal preparation on the quality of apical and coronal obturation.

Authors:  D A Allison; C R Weber; R E Walton
Journal:  J Endod       Date:  1979-10       Impact factor: 4.171

6.  Root canal instruments are poorly standardized.

Authors:  E Stenman; L S Spångberg
Journal:  J Endod       Date:  1993-07       Impact factor: 4.171

7.  Lateral condensation stress in root canals.

Authors:  T E Harvey; J T White; I J Leeb
Journal:  J Endod       Date:  1981-04       Impact factor: 4.171

8.  Vertical root fracture and root distortion: effect of spreader design.

Authors:  D A Dang; R E Walton
Journal:  J Endod       Date:  1989-07       Impact factor: 4.171

9.  Comparison of spreader penetration during lateral compaction of .04 and .02 tapered gutta-percha.

Authors:  Brian L Wilson; J Craig Baumgartner
Journal:  J Endod       Date:  2003-12       Impact factor: 4.171

10.  Photoelastic comparison of stress induced by using stainless-steel versus nickel-titanium spreaders in vitro.

Authors:  A P Joyce; R J Loushine; L A West; D A Runyan; S M Cameron
Journal:  J Endod       Date:  1998-11       Impact factor: 4.171

View more
  1 in total

1.  Strain Distribution in Root Surface Dentin of Maxillary Central Incisors during Lateral Compaction.

Authors:  Raphael Pilo; Zvi Metzger; Tamar Brosh
Journal:  PLoS One       Date:  2016-05-26       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.