Literature DB >> 16011768

A comparison of spreader penetration depth and load required during lateral condensation in teeth prepared using various root canal preparation techniques.

S F Dulaimi1, M K Wali Al-Hashimi.   

Abstract

AIM: To compare the influence of various root canal preparation techniques on spreader penetration depth and load required during lateral condensation with gutta-percha and sealer.
METHODOLOGY: Eighty extracted human teeth with single and straight canals were used. Twenty teeth were instrumented using one of four root canal preparation techniques. The four preparation techniques were: step-back technique without Gates-Glidden drills, step-back technique with Gates-Glidden drills, crown-down pressureless technique and hybrid technique (step-down/step-back). After root canal preparation had been completed a simulated periodontal ligament was fabricated from a uniform layer of silicone impression material. The roots were then mounted in an acrylic resin to simulate the physical condition found in tooth socket. A standardized stainless steel hand spreader of the same size as the master apical file was mounted in an Instron testing machine and lateral compaction with gutta-percha and sealer was performed. The load value was recorded from the Instron testing machine. The spreader penetration depths were measured with an endodontic ruler. The data obtained were analysed statistically using anova and Student's t-tests.
RESULTS: No significant difference in initial spreader load needed to condense the master cone was found amongst the four canal preparation techniques (P > 0.05). The step-back technique with Gates-Glidden drills and the hybrid technique demonstrated the least difference between the initial spreader penetration and the working length (mean 1.925 and 2.25 mm, respectively). The step-back technique without Gates-Glidden drills and the crown-down pressureless technique had the greatest difference between initial spreader penetration and the working length (mean 4.425 and 4.75 mm, respectively).
CONCLUSION: The flare created by canal preparation affected spreader penetration depth, but had no effect on the spreader load.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16011768     DOI: 10.1111/j.1365-2591.2005.00969.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  3 in total

1.  Comparison of some physical properties of finger spreaders made of stainless steel or nickel-titanium alloys.

Authors:  Hélio P Lopes; Mônica A S Neves; Carlos N Elias; Edson J L Moreira; José F Siqueira
Journal:  Clin Oral Investig       Date:  2010-06-29       Impact factor: 3.573

2.  Effect of the simulated periodontal ligament on cast post-and-core removal using an ultrasonic device.

Authors:  Manoel Brito-Junior; Neilor Mateus Antunes Braga; Danilo Costa Rodrigues; Carla Cristina Camilo; André Luis Faria-e-Silva
Journal:  J Appl Oral Sci       Date:  2010 Sep-Oct       Impact factor: 2.698

3.  Comparison of first accessory cone penetration after using stainless-steel and ni-ti spreaders in curved resin blocks.

Authors:  Nahid Mohammadzade Akhlaghi; Nasrin Roghanizad; Zohreh Khalilak; Neda Rezaie
Journal:  Iran Endod J       Date:  2008-01-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.