Literature DB >> 20561678

A comparison of the tissue response to chronically implanted Parylene-C-coated and uncoated planar silicon microelectrode arrays in rat cortex.

Brent D Winslow1, Michael B Christensen, Wen-Kuo Yang, Florian Solzbacher, Patrick A Tresco.   

Abstract

In this study we employed a quantitative immunohistochemical approach to compare the brain tissue response to planar silicon microelectrode arrays that were conformally coated with Parylene-C to uncoated controls at 2, 4, and 12 weeks following implantation into the cortex of adult male Sprague-Dawley rats. We did not find any difference in the relative intensity or the spatial distribution of neuronal or glial markers over the indwelling period, even though Parylene-C-coated substrates supported significantly less cell attachment, indicating that the foreign body response to planar silicon microelectrode arrays has little to do with the composition or decomposition of the silicon electrode. Moreover, our results suggest that changes in microelectrode surface chemistry do not have a strong influence on the cytoarchitectural changes that accompany the brain foreign body response to planar silicon microelectrode arrays. Our quantitative comparison over the indwelling period does not support progressive increases in astrocyte encapsulation and/or progressive neuronal loss in the recording zone as dominant failure mechanisms of the type of chronic recording device. Finally, we found evidence of two potentially new failure mechanisms that were associated with CD68 immunoreactivity including demyelination of adjacent neurons and BBB breakdown surrounding implanted electrodes at long indwelling times.
Copyright © 2010. Published by Elsevier Ltd.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20561678     DOI: 10.1016/j.biomaterials.2010.05.050

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  60 in total

1.  Mechanically adaptive intracortical implants improve the proximity of neuronal cell bodies.

Authors:  J P Harris; J R Capadona; R H Miller; B C Healy; K Shanmuganathan; S J Rowan; C Weder; D J Tyler
Journal:  J Neural Eng       Date:  2011-11-02       Impact factor: 5.379

2.  Biohybrid Carbon Nanotube/Agarose Fibers for Neural Tissue Engineering.

Authors:  Dan Y Lewitus; John Landers; Jonathan Branch; Karen L Smith; Gerardo Callegari; Joachim Kohn; Alexander V Neimark
Journal:  Adv Funct Mater       Date:  2011-07-22       Impact factor: 18.808

3.  In vivo polymerization of poly(3,4-ethylenedioxythiophene) in the living rat hippocampus does not cause a significant loss of performance in a delayed alternation task.

Authors:  Liangqi Ouyang; Crystal L Shaw; Chin-Chen Kuo; Amy L Griffin; David C Martin
Journal:  J Neural Eng       Date:  2014-02-06       Impact factor: 5.379

4.  Mechanically-compliant intracortical implants reduce the neuroinflammatory response.

Authors:  Jessica K Nguyen; Daniel J Park; John L Skousen; Allison E Hess-Dunning; Dustin J Tyler; Stuart J Rowan; Christoph Weder; Jeffrey R Capadona
Journal:  J Neural Eng       Date:  2014-08-15       Impact factor: 5.379

5.  Inhibition of the cluster of differentiation 14 innate immunity pathway with IAXO-101 improves chronic microelectrode performance.

Authors:  John K Hermann; Madhumitha Ravikumar; Andrew J Shoffstall; Evon S Ereifej; Kyle M Kovach; Jeremy Chang; Arielle Soffer; Chun Wong; Vishnupriya Srivastava; Patrick Smith; Grace Protasiewicz; Jingle Jiang; Stephen M Selkirk; Robert H Miller; Steven Sidik; Nicholas P Ziats; Dawn M Taylor; Jeffrey R Capadona
Journal:  J Neural Eng       Date:  2018-04       Impact factor: 5.379

6.  Intracranial EEG fluctuates over months after implanting electrodes in human brain.

Authors:  Hoameng Ung; Steven N Baldassano; Hank Bink; Abba M Krieger; Shawniqua Williams; Flavia Vitale; Chengyuan Wu; Dean Freestone; Ewan Nurse; Kent Leyde; Kathryn A Davis; Mark Cook; Brian Litt
Journal:  J Neural Eng       Date:  2017-09-01       Impact factor: 5.379

7.  Cuprizone-induced oligodendrocyte loss and demyelination impairs recording performance of chronically implanted neural interfaces.

Authors:  Steven M Wellman; Kelly Guzman; Kevin C Stieger; Lauren E Brink; Sadhana Sridhar; Mitchell T Dubaniewicz; Lehong Li; Franca Cambi; Takashi D Y Kozai
Journal:  Biomaterials       Date:  2020-02-06       Impact factor: 12.479

8.  The Effect of Residual Endotoxin Contamination on the Neuroinflammatory Response to Sterilized Intracortical Microelectrodes.

Authors:  Madhumitha Ravikumar; Daniel J Hageman; William H Tomaszewski; Gabriella M Chandra; John L Skousen; Jeffrey R Capadona
Journal:  J Mater Chem B       Date:  2014-05-07       Impact factor: 6.331

9.  Engineered Axonal Tracts as "Living Electrodes" for Synaptic-Based Modulation of Neural Circuitry.

Authors:  Mijail D Serruya; James P Harris; Dayo O Adewole; Laura A Struzyna; Justin C Burrell; Ashley Nemes; Dmitriy Petrov; Reuben H Kraft; H Isaac Chen; John A Wolf; D Kacy Cullen
Journal:  Adv Funct Mater       Date:  2017-09-04       Impact factor: 18.808

10.  In vivo two-photon microscopy reveals immediate microglial reaction to implantation of microelectrode through extension of processes.

Authors:  Takashi D Yoshida Kozai; Alberto L Vazquez; Cassandra L Weaver; Seong-Gi Kim; X Tracy Cui
Journal:  J Neural Eng       Date:  2012-10-17       Impact factor: 5.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.