Literature DB >> 22049097

Mechanically adaptive intracortical implants improve the proximity of neuronal cell bodies.

J P Harris1, J R Capadona, R H Miller, B C Healy, K Shanmuganathan, S J Rowan, C Weder, D J Tyler.   

Abstract

The hypothesis is that the mechanical mismatch between brain tissue and microelectrodes influences the inflammatory response. Our unique, mechanically adaptive polymer nanocomposite enabled this study within the cerebral cortex of rats. The initial tensile storage modulus of 5 GPa decreases to 12 MPa within 15 min under physiological conditions. The response to the nanocomposite was compared to surface-matched, stiffer implants of traditional wires (411 GPa) coated with the identical polymer substrate and implanted on the contralateral side. Both implants were tethered. Fluorescent immunohistochemistry labeling examined neurons, intermediate filaments, macrophages, microglia and proteoglycans. We demonstrate, for the first time, a system that decouples the mechanical and surface chemistry components of the neural response. The neuronal nuclei density within 100 µm of the device at four weeks post-implantation was greater for the compliant nanocomposite compared to the stiff wire. At eight weeks post-implantation, the neuronal nuclei density around the nanocomposite was maintained, but the density around the wire recovered to match that of the nanocomposite. The glial scar response to the compliant nanocomposite was less vigorous than it was to the stiffer wire. The results suggest that mechanically associated factors such as proteoglycans and intermediate filaments are important modulators of the response of the compliant nanocomposite.

Entities:  

Mesh:

Year:  2011        PMID: 22049097      PMCID: PMC3386315          DOI: 10.1088/1741-2560/8/6/066011

Source DB:  PubMed          Journal:  J Neural Eng        ISSN: 1741-2552            Impact factor:   5.379


  50 in total

1.  Stability of the interface between neural tissue and chronically implanted intracortical microelectrodes.

Authors:  X Liu; D B McCreery; R R Carter; L A Bullara; T G Yuen; W F Agnew
Journal:  IEEE Trans Rehabil Eng       Date:  1999-09

Review 2.  Mechanosensation and endothelin in astrocytes--hypothetical roles in CNS pathophysiology.

Authors:  Lyle W Ostrow; Frederick Sachs
Journal:  Brain Res Brain Res Rev       Date:  2004-10-28

3.  Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays.

Authors:  Roy Biran; David C Martin; Patrick A Tresco
Journal:  Exp Neurol       Date:  2005-09       Impact factor: 5.330

4.  In vivo deployment of mechanically adaptive nanocomposites for intracortical microelectrodes.

Authors:  J P Harris; A E Hess; S J Rowan; C Weder; C A Zorman; D J Tyler; J R Capadona
Journal:  J Neural Eng       Date:  2011-06-08       Impact factor: 5.379

5.  Use of cryoprotectant to maintain long-term peptide immunoreactivity and tissue morphology.

Authors:  R E Watson; S J Wiegand; R W Clough; G E Hoffman
Journal:  Peptides       Date:  1986 Jan-Feb       Impact factor: 3.750

6.  Diffusion barriers evoked in the rat cortex by reactive astrogliosis.

Authors:  T Roitbak; E Syková
Journal:  Glia       Date:  1999-10       Impact factor: 7.452

7.  Parylene flexible neural probes integrated with microfluidic channels.

Authors:  Shoji Takeuchi; D Ziegler; Y Yoshida; K Mabuchi; T Suzuki
Journal:  Lab Chip       Date:  2005-04-12       Impact factor: 6.799

Review 8.  The glial scar and central nervous system repair.

Authors:  J W Fawcett; R A Asher
Journal:  Brain Res Bull       Date:  1999-08       Impact factor: 4.077

9.  NG2 proteoglycan-expressing cells of the adult rat brain: possible involvement in the formation of glial scar astrocytes following stab wound.

Authors:  G Alonso
Journal:  Glia       Date:  2005-02       Impact factor: 7.452

10.  Cellular dynamics of macrophages and microglial cells in reaction to stab wounds in rat cerebral cortex.

Authors:  T Fujita; T Yoshimine; M Maruno; T Hayakawa
Journal:  Acta Neurochir (Wien)       Date:  1998       Impact factor: 2.216

View more
  70 in total

1.  Implantable electronics: A sensor web for neurons.

Authors:  Tarun Saxena; Ravi V Bellamkonda
Journal:  Nat Mater       Date:  2015-12       Impact factor: 43.841

2.  Environmentally-controlled microtensile testing of mechanically-adaptive polymer nanocomposites for ex vivo characterization.

Authors:  Allison E Hess; Kelsey A Potter; Dustin J Tyler; Christian A Zorman; Jeffrey R Capadona
Journal:  J Vis Exp       Date:  2013-08-20       Impact factor: 1.355

3.  Glial responses to implanted electrodes in the brain.

Authors:  Joseph W Salatino; Kip A Ludwig; Takashi D Y Kozai; Erin K Purcell
Journal:  Nat Biomed Eng       Date:  2017-11-10       Impact factor: 25.671

4.  Compliant intracortical implants reduce strains and strain rates in brain tissue in vivo.

Authors:  Arati Sridharan; Jessica K Nguyen; Jeffrey R Capadona; Jit Muthuswamy
Journal:  J Neural Eng       Date:  2015-04-02       Impact factor: 5.379

5.  Toward guiding principles for the design of biologically-integrated electrodes for the central nervous system.

Authors:  Cort H Thompson; Ti'Air E Riggins; Paras R Patel; Cynthia A Chestek; Wen Li; Erin Purcell
Journal:  J Neural Eng       Date:  2020-03-12       Impact factor: 5.379

6.  Wireless opto-electro neural interface for experiments with small freely behaving animals.

Authors:  Yaoyao Jia; Wasif Khan; Byunghun Lee; Bin Fan; Fatma Madi; Arthur Weber; Wen Li; Maysam Ghovanloo
Journal:  J Neural Eng       Date:  2018-05-25       Impact factor: 5.379

7.  Insertion of flexible neural probes using rigid stiffeners attached with biodissolvable adhesive.

Authors:  Sarah H Felix; Kedar G Shah; Vanessa M Tolosa; Heeral J Sheth; Angela C Tooker; Terri L Delima; Shantanu P Jadhav; Loren M Frank; Satinderpall S Pannu
Journal:  J Vis Exp       Date:  2013-09-27       Impact factor: 1.355

8.  The Effect of Residual Endotoxin Contamination on the Neuroinflammatory Response to Sterilized Intracortical Microelectrodes.

Authors:  Madhumitha Ravikumar; Daniel J Hageman; William H Tomaszewski; Gabriella M Chandra; John L Skousen; Jeffrey R Capadona
Journal:  J Mater Chem B       Date:  2014-05-07       Impact factor: 6.331

9.  Evaluation of poly(3,4-ethylenedioxythiophene)/carbon nanotube neural electrode coatings for stimulation in the dorsal root ganglion.

Authors:  Christi L Kolarcik; Kasey Catt; Erika Rost; Ingrid N Albrecht; Dennis Bourbeau; Zhanhong Du; Takashi D Y Kozai; Xiliang Luo; Douglas J Weber; X Tracy Cui
Journal:  J Neural Eng       Date:  2014-12-08       Impact factor: 5.379

10.  Engineered Axonal Tracts as "Living Electrodes" for Synaptic-Based Modulation of Neural Circuitry.

Authors:  Mijail D Serruya; James P Harris; Dayo O Adewole; Laura A Struzyna; Justin C Burrell; Ashley Nemes; Dmitriy Petrov; Reuben H Kraft; H Isaac Chen; John A Wolf; D Kacy Cullen
Journal:  Adv Funct Mater       Date:  2017-09-04       Impact factor: 18.808

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.