Literature DB >> 20557740

The Hydrodynamic Effect of Bare Platinum Coils versus Hydrogel-Coated Platinum Coils.

A Sorteberg1, S J Bakke.   

Abstract

SUMMARY: HydroCoils (HES) were designed to obtain a better initial aneurysm occlusion and increased durability of endovascular treatment. We compared the immediate hydrodynamic effects of HES versus bare platinum coils (Guglielmi detachable coils, GDC). Intra-aneurysmal pressure and flow were measured with a 0.014 inch guidewire mounted transducer in silicone aneurysms mounted onto a pulsatile flow phantom before and after consecutively coiling with GDC and HES. We evaluated flow using the thermodilution technique along with changes in steady pressure and sudden increases in pressure. We also considered the effect of the coils on the transmission of pressure from the parent artery to the dome of the aneurysm. Intra-aneurysmal pressure remained unchanged after maximal packing with either GDC or HES. Sudden increases in pressure were less attenuated within the aneurysm after coiling with HES. In spite of HES obtaining a much higher percentage filling volume in the aneurysms, GDC equivalently virtually abolished intra-aneurysmal flow apart from in one instance where there was significant persistent flow after coiling with GDC. The effects of HES in terms of pressure and flow attenuation within the aneurysm could hence not be proven superior to GDC.

Entities:  

Year:  2009        PMID: 20557740      PMCID: PMC3313808          DOI: 10.1177/159101990801400406

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  17 in total

1.  Changes in the intraaneurysmal pressure due to HydroCoil embolization.

Authors:  Gádor Cantón; David I Levy; Juan C Lasheras
Journal:  AJNR Am J Neuroradiol       Date:  2005-04       Impact factor: 3.825

2.  Effect of Guglielmi detachable coils on intraaneurysmal flow: experimental study in canines.

Authors:  Angelika Sorteberg; Wilhelm Sorteberg; Alan Rappe; Charles M Strother
Journal:  AJNR Am J Neuroradiol       Date:  2002-02       Impact factor: 3.825

3.  Angiographic and histologic analysis of experimental aneurysms embolized with platinum coils, Matrix, and HydroCoil.

Authors:  Yong Hong Ding; Daying Dai; Debra A Lewis; Harry J Cloft; David F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2005-08       Impact factor: 3.825

4.  Treatment of cerebral aneurysms with hydrogel-coated platinum coils (HydroCoil): early single-center experience.

Authors:  A Berenstein; J K Song; Y Niimi; K Namba; N S Heran; J L Brisman; M C Nahoum; M Madrid; D J Langer; M J Kupersmith
Journal:  AJNR Am J Neuroradiol       Date:  2006-10       Impact factor: 3.825

5.  Ex vivo study of the physical effect of coils on pressure and flow dynamics in experimental aneurysms.

Authors:  H G Boecher-Schwarz; K Ringel; L Kopacz; A Heimann; O Kempski
Journal:  AJNR Am J Neuroradiol       Date:  2000-09       Impact factor: 3.825

6.  Embolization of intracranial aneurysms with hydrogel-coated coils versus inert platinum coils: effects on packing density, coil length and quantity, procedure performance, cost, length of hospital stay, and durability of therapy.

Authors:  Ron C Gaba; Sameer A Ansari; Soma Sinha Roy; Franklin A Marden; Marlos A G Viana; Tim W Malisch
Journal:  Stroke       Date:  2006-05-04       Impact factor: 7.914

7.  Aneurysm packing with HydroCoil Embolic System versus platinum coils: initial clinical experience.

Authors:  Harry J Cloft; David F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2004-01       Impact factor: 3.825

8.  The use of hydrocoil for parent artery occlusion.

Authors:  David F Kallmes; Harry J Cloft
Journal:  AJNR Am J Neuroradiol       Date:  2004-09       Impact factor: 3.825

9.  In vitro study of haemodynamics in a giant saccular aneurysm model: influence of flow dynamics in the parent vessel and effects of coil embolisation.

Authors:  Y P Gobin; J L Counord; P Flaud; J Duffaux
Journal:  Neuroradiology       Date:  1994-10       Impact factor: 2.804

10.  A prospective single-center analysis of the safety and efficacy of the hydrocoil embolization system for the treatment of intracranial aneurysms.

Authors:  Eric M Deshaies; Matthew A Adamo; Alan S Boulos
Journal:  J Neurosurg       Date:  2007-02       Impact factor: 5.115

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.