Literature DB >> 16091526

Angiographic and histologic analysis of experimental aneurysms embolized with platinum coils, Matrix, and HydroCoil.

Yong Hong Ding1, Daying Dai, Debra A Lewis, Harry J Cloft, David F Kallmes.   

Abstract

BACKGROUND AND
PURPOSE: A report directly comparing platinum coils, Matrix coils, and HydroCoils in a single animal model does not currently exist. We evaluated and compared the performance of these three products in the embolization of experimental aneurysms.
METHODS: Thirty-three elastase-induced saccular aneurysms were created in rabbits. Aneurysms were embolized with Matrix coils (n = 15), HydroCoils (n = 9), or platinum coils (n = 9). The groups were compared with respect to the following parameters: aneurysm size, procedure duration, number and total length of devices deposited, angiographic occlusion score, and volumetric occlusion percentage. Follow-up angiographic and histologic features at 2, 6, and 10 weeks after embolization were analyzed. Groups were compared by using analysis of variance and chi2 tests.
RESULTS: No significant differences were found among groups regarding aneurysm size, total device length, initial angiographic occlusion score, or procedure time. The mean number of devices for Matrix subjects was less than that for platinum coils (P = .02) and HydroCoil (P = .03). Volumetric occlusion for HydroCoil (76%) was significantly greater (P < .0001) than both platinum coils (31%) and Matrix (23%). Angiographic durability was significantly increased in the HydroCoil group compared with Matrix (P = .03). Coil compaction was found more frequently in the Matrix group (five cases, 33%) than the HydroCoil (no cases, 0%), or platinum coil groups (two cases, 22%). The Matrix group showed greater tissue reaction compared with platinum coils (P < .05).
CONCLUSION: In the rabbit model, the use of HydroCoils results in improved long-term occlusion rates compared with Matrix and platinum coils. The Matrix group showed an increase in inflammation and coil compaction compared with HydroCoils and platinum coils.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16091526      PMCID: PMC7975154     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  33 in total

1.  1999 ARRS Executive Council Award. Creation of saccular aneurysms in the rabbit: a model suitable for testing endovascular devices. American Roentgen Ray Society.

Authors:  T A Altes; H J Cloft; J G Short; A DeGast; H M Do; G A Helm; D F Kallmes
Journal:  AJR Am J Roentgenol       Date:  2000-02       Impact factor: 3.959

2.  Bioabsorbable polymeric material coils for embolization of intracranial aneurysms: a preliminary experimental study.

Authors:  Y Murayama; F Viñuela; S Tateshima; J K Song; N R Gonzalez; M P Wallace
Journal:  J Neurosurg       Date:  2001-03       Impact factor: 5.115

3.  Histologic evaluation of platinum coil embolization in an aneurysm model in rabbits.

Authors:  D F Kallmes; G A Helm; S B Hudson; T A Altes; H M Do; J W Mandell; H J Cloft
Journal:  Radiology       Date:  1999-10       Impact factor: 11.105

4.  Gross and microscopic histopathological findings in aneurysms of the human brain treated with Guglielmi detachable coils.

Authors:  G Bavinzski; V Talazoglu; M Killer; B Richling; A Gruber; C E Gross; H Plenk
Journal:  J Neurosurg       Date:  1999-08       Impact factor: 5.115

5.  Histopathological findings in experimental aneurysms embolized with conventional and thrombogenic/antithrombolytic Guglielmi coils.

Authors:  G Bavinzski; B Richling; B R Binder; A Gruber; V Talazoglu; W Dietrich; I Schwendtenwein; H Plenk
Journal:  Minim Invasive Neurosurg       Date:  1999-12

6.  Scanning electron microscopic findings in a basilar tip aneurysm embolized with Guglielmi detachable coils.

Authors:  M B Horowitz; P D Purdy; D Burns; D Bellotto
Journal:  AJNR Am J Neuroradiol       Date:  1997-04       Impact factor: 3.825

7.  Matrix and bioabsorbable polymeric coils accelerate healing of intracranial aneurysms: long-term experimental study.

Authors:  Yuichi Murayama; Satoshi Tateshima; Nestor R Gonzalez; Fernando Vinuela
Journal:  Stroke       Date:  2003-07-17       Impact factor: 7.914

8.  Role of the endothelial lining in recurrences after coil embolization: prevention of recanalization by endothelial denudation.

Authors:  Jean Raymond; François Guilbert; Annick Metcalfe; Guylaine Gévry; Igor Salazkin; Olivier Robledo
Journal:  Stroke       Date:  2004-04-22       Impact factor: 7.914

9.  Aneurysm packing with HydroCoil Embolic System versus platinum coils: initial clinical experience.

Authors:  Harry J Cloft; David F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2004-01       Impact factor: 3.825

10.  Endovascular occlusion of intracranial aneurysms with electrically detachable coils: correlation of aneurysm neck size and treatment results.

Authors:  A Fernandez Zubillaga; G Guglielmi; F Viñuela; G R Duckwiler
Journal:  AJNR Am J Neuroradiol       Date:  1994-05       Impact factor: 3.825

View more
  52 in total

1.  In vitro performance of a shape memory polymer foam-coated coil embolization device.

Authors:  Anthony J Boyle; Mark A Wierzbicki; Scott Herting; Andrew C Weems; Adam Nathan; Wonjun Hwang; Duncan J Maitland
Journal:  Med Eng Phys       Date:  2017-07-31       Impact factor: 2.242

Review 2.  Review of 2 decades of aneurysm-recurrence literature, part 1: reducing recurrence after endovascular coiling.

Authors:  E Crobeddu; G Lanzino; D F Kallmes; H J Cloft
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-15       Impact factor: 3.825

3.  Bare, bio-active and hydrogel-coated coils for endovascular treatment of experimentally induced aneurysms. Long-term histological and scanning electron microscopy results.

Authors:  M H T Reinges; T Krings; A Y Drexler; A Ludolph; B Sellhaus; M Bovi; S Geibprasert; R Agid; K Scherer; F J Hans
Journal:  Interv Neuroradiol       Date:  2010-07-19       Impact factor: 1.610

4.  HydroCoil as an adjuvant to bare platinum coil treatment of 100 cerebral aneurysms.

Authors:  Noel F Fanning; Zsolt Berentei; Paul R Brennan; John Thornton
Journal:  Neuroradiology       Date:  2006-11-22       Impact factor: 2.804

5.  Endovascular treatment of intracranial aneurysms with matrix detachable coils: immediate posttreatment results from a prospective multicenter registry.

Authors:  L Pierot; A Bonafé; S Bracard; X Leclerc
Journal:  AJNR Am J Neuroradiol       Date:  2006-09       Impact factor: 3.825

6.  Endovascular treatment of intracranial aneurysms with matrix coils: immediate posttreatment results, clinical outcome and follow-up.

Authors:  T Jonas Kimchi; R A Willinsky; J Spears; S K Lee; K ter Brugge
Journal:  Neuroradiology       Date:  2007-01-03       Impact factor: 2.804

Review 7.  From bench to bedside: utility of the rabbit elastase aneurysm model in preclinical studies of intracranial aneurysm treatment.

Authors:  Waleed Brinjikji; Yong H Ding; David F Kallmes; Ramanathan Kadirvel
Journal:  J Neurointerv Surg       Date:  2015-04-22       Impact factor: 5.836

Review 8.  Stents for intracranial wide-necked aneurysms: more than mechanical protection.

Authors:  Isabel Wanke; Michael Forsting
Journal:  Neuroradiology       Date:  2008-09-20       Impact factor: 2.804

9.  Isolated progressive visual loss after coiling of paraclinoid aneurysms.

Authors:  G W Schmidt; S F Oster; K C Golnik; L M Tumialán; V Biousse; R Turbin; C J Prestigiacomo; N R Miller
Journal:  AJNR Am J Neuroradiol       Date:  2007 Nov-Dec       Impact factor: 3.825

10.  HydroCoils reduce recurrence rates in recently ruptured medium-sized intracranial aneurysms: a subgroup analysis of the HELPS trial.

Authors:  W Brinjikji; P M White; H Nahser; J Wardlaw; R Sellar; H J Cloft; D F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2015-03-12       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.