Literature DB >> 14729529

Aneurysm packing with HydroCoil Embolic System versus platinum coils: initial clinical experience.

Harry J Cloft1, David F Kallmes.   

Abstract

The HydroCoil Embolic System (HES; MicroVention, Aliso Viejo, CA) was developed to improve the efficacy of endovascular treatment of cerebral aneurysms. The HES may reduce recurrences of aneurysms by allowing for increased packing density as compared with platinum coils. We report our initial experience with the HES in the treatment of 11 patients with cerebral aneurysms and compare findings to those in size-matched control cases treated with platinum coils. The HES provided substantially improved volumetric packing of the aneurysm lumen relative to standard platinum coils (73% vs. 32%; P=.0001).

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14729529      PMCID: PMC7974178     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  9 in total

1.  Intracranial Aneurysm Embolization Using Interlocking Detachable Coils. Correlation between Volume Embolization Rate and Coil Compaction.

Authors:  K Satoh; S Matsubara; H Hondoh; S Nagahiro
Journal:  Interv Neuroradiol       Date:  2001-05-15       Impact factor: 1.610

2.  Evaluation of the stability of aneurysms after embolization using detachable coils: correlation between stability of aneurysms and embolized volume of aneurysms.

Authors:  Shinichi Tamatani; Yasushi Ito; Hiroshi Abe; Tetsuo Koike; Shigekazu Takeuchi; Ryuichi Tanaka
Journal:  AJNR Am J Neuroradiol       Date:  2002-05       Impact factor: 3.825

3.  Long-term angiographic follow-up of 169 intracranial berry aneurysms occluded with detachable coils.

Authors:  C Cognard; A Weill; L Spelle; M Piotin; L Castaings; A Rey; J Moret
Journal:  Radiology       Date:  1999-08       Impact factor: 11.105

4.  Endovascular occlusion of intracranial aneurysms with Guglielmi detachable coils: correlation between coil packing density and coil compaction.

Authors:  Y Kawanabe; A Sadato; W Taki; N Hashimoto
Journal:  Acta Neurochir (Wien)       Date:  2001       Impact factor: 2.216

5.  New expandable hydrogel-platinum coil hybrid device for aneurysm embolization.

Authors:  David F Kallmes; Naomi H Fujiwara
Journal:  AJNR Am J Neuroradiol       Date:  2002-10       Impact factor: 3.825

6.  Clinical and angiographic results of endosaccular coiling treatment of giant and very large intracranial aneurysms: a 7-year, single-center experience.

Authors:  A Gruber; M Killer; G Bavinzski; B Richling
Journal:  Neurosurgery       Date:  1999-10       Impact factor: 4.654

7.  Significance of volume embolization ratio as a predictor of recanalization on endovascular treatment of cerebral aneurysms with guglielmi detachable coils.

Authors:  N Uchiyama; S Kida; M Nomura; M Hasegawa; T Yamashima; J Yamashita; O Matsui
Journal:  Interv Neuroradiol       Date:  2001-05-15       Impact factor: 1.610

Review 8.  Selection of cerebral aneurysms for treatment using Guglielmi detachable coils: the preliminary University of Illinois at Chicago experience.

Authors:  G M Debrun; V A Aletich; P Kehrli; M Misra; J I Ausman; F Charbel
Journal:  Neurosurgery       Date:  1998-12       Impact factor: 4.654

9.  Clinical and angiographic outcomes, with treatment data, for patients with cerebral aneurysms treated with Guglielmi detachable coils: a single-center experience.

Authors:  T A Kuether; G M Nesbit; S L Barnwell
Journal:  Neurosurgery       Date:  1998-11       Impact factor: 4.654

  9 in total
  58 in total

1.  In vitro performance of a shape memory polymer foam-coated coil embolization device.

Authors:  Anthony J Boyle; Mark A Wierzbicki; Scott Herting; Andrew C Weems; Adam Nathan; Wonjun Hwang; Duncan J Maitland
Journal:  Med Eng Phys       Date:  2017-07-31       Impact factor: 2.242

Review 2.  Review of 2 decades of aneurysm-recurrence literature, part 1: reducing recurrence after endovascular coiling.

Authors:  E Crobeddu; G Lanzino; D F Kallmes; H J Cloft
Journal:  AJNR Am J Neuroradiol       Date:  2012-03-15       Impact factor: 3.825

3.  Short-term outcome of intracranial aneurysms treated with polyglycolic acid/lactide copolymer-coated coils compared to historical controls treated with bare platinum coils: a single-center experience.

Authors:  Hyun-Seung Kang; Moon Hee Han; Bae Ju Kwon; O-Ki Kwon; Sung Hyun Kim; Seung Hong Choi; Kee-Hyun Chang
Journal:  AJNR Am J Neuroradiol       Date:  2005-09       Impact factor: 3.825

4.  HydroCoil as an adjuvant to bare platinum coil treatment of 100 cerebral aneurysms.

Authors:  Noel F Fanning; Zsolt Berentei; Paul R Brennan; John Thornton
Journal:  Neuroradiology       Date:  2006-11-22       Impact factor: 2.804

5.  Cerecyte coils in the treatment of intracranial aneurysms: a preliminary clinical study.

Authors:  M Bendszus; L Solymosi
Journal:  AJNR Am J Neuroradiol       Date:  2006 Nov-Dec       Impact factor: 3.825

6.  Treatment and follow-up of 22 unruptured wide-necked intracranial aneurysms of the internal carotid artery with Onyx HD 500.

Authors:  Werner Weber; Ralf Siekmann; Bernhard Kis; Dietmar Kuehne
Journal:  AJNR Am J Neuroradiol       Date:  2005-09       Impact factor: 3.825

7.  Volume measurement of intracranial aneurysms from 3D rotational angiography: improvement of accuracy by gradient edge detection.

Authors:  Javier Oliván Bescós; Marjan J Slob; Cornelis H Slump; Menno Sluzewski; Willem Jan van Rooij
Journal:  AJNR Am J Neuroradiol       Date:  2005 Nov-Dec       Impact factor: 3.825

8.  Endovascular treatment of intracranial aneurysms with matrix coils: a preliminary study of immediate post-treatment results.

Authors:  Boris Lubicz; Xavier Leclerc; Jean-Yves Gauvrit; Jean-Paul Lejeune; Jean-Pierre Pruvo
Journal:  AJNR Am J Neuroradiol       Date:  2005-02       Impact factor: 3.825

9.  Treatment options for wide-necked intracranial aneurysms using a self-expandable hydrophilic coil and a self-expandable stent combination.

Authors:  Jonathan L Brisman; Joon K Song; Yasunari Niimi; Alejandro Berenstein
Journal:  AJNR Am J Neuroradiol       Date:  2005-05       Impact factor: 3.825

10.  HydroCoils reduce recurrence rates in recently ruptured medium-sized intracranial aneurysms: a subgroup analysis of the HELPS trial.

Authors:  W Brinjikji; P M White; H Nahser; J Wardlaw; R Sellar; H J Cloft; D F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2015-03-12       Impact factor: 3.825

View more