Literature DB >> 14598895

Assessment of vasoreactivity using videodensitometry coronary angiography.

Sabee Molloi1, Gholam R Berenji, Trien T Dang, Ghassan Kassab.   

Abstract

BACKGROUND: Previous studies demonstrated that the dysfunction of vasomotor tone (VT) is closely linked to the development of atherosclerosis and it is considered important in the very early stages of atherogenesis. Currently, the evaluation of VT relies on lumen changes in response to vasoactive stimuli using quantitative coronary angiography (QCA) based on geometric edge detection (ED). However, using ED for measuring lumen diameters is inherently associated with large uncertainties. Videodensitometry (VD) methods have important advantages over ED for QCA. The objective of this study was to investigate the reliability of VD and ED techniques in determining the effect of nitroglycerin (NTG) on cross-sectional area (CSA) and volume changes in a swine animal model for evaluating coronary vasoreactivity. METHODS AND
RESULTS: Coronary angiography was performed on four anesthetized swine. CSA and volume were measured in the left anterior descending (LAD) coronary artery using VD before and after intracoronary injection of 0.3 mg of NTG. CSA was also calculated using standard QCA based on ED. The average CSA changes in the proximal, middle and distal branches measured using VD were 23.83% (+/-10.76%), 30.78% (+/-18.39%), and 27.34% (+/-36.53%), respectively. Similarly, the average CSA changes in the proximal, middle, and distal branches measured using ED were 15.02% (+/-36.38%), 22.02% (+/-26.12), and 38.00% (+/-48.31%), respectively. The average lumen volume change measured using VD was 29.79% (+/-14.79%). In order to evaluate the relative reliability of the techniques. the significance of deviation (SOD) was calculated, which is the ratio of the change after NTG and the measurement error. The average SOD for CSA for all the branches based on VD and ED were 1.86 and 0.69, respectively. The SOD for volume measurement was 2.78.
CONCLUSIONS: Lumen changes measured by VD showed substantial improvement in reliability when compared to the ED. Moreover, VD can be used to measure substantially smaller changes in lumen dimension in response to vasoactive stimuli than the standard QCA based on ED. Finally, VD allows the measurement of arterial volume, which is not possible with ED.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14598895     DOI: 10.1023/a:1025412203223

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  30 in total

1.  Cross-sectional area and volume compliance of porcine left coronary arteries.

Authors:  G S Kassab; S Molloi
Journal:  Am J Physiol Heart Circ Physiol       Date:  2001-08       Impact factor: 4.733

2.  Prognostic impact of coronary vasodilator dysfunction on adverse long-term outcome of coronary heart disease.

Authors:  V Schächinger; M B Britten; A M Zeiher
Journal:  Circulation       Date:  2000-04-25       Impact factor: 29.690

Review 3.  Morphometric versus densitometric assessment of coronary vasomotor tone--an overview.

Authors:  P A Doriot; N Guggenheim; P A Dorsaz; W Rutishauser
Journal:  Eur Heart J       Date:  1989-11       Impact factor: 29.983

4.  Nitroglycerin-induced coronary vasodilation is not enhanced in patients with impaired endothelium-dependent dilation.

Authors:  T J Anderson; I T Meredith; F Charbonneau; A C Yeung; M Dyce; A P Selwyn; P Ganz
Journal:  J Am Coll Cardiol       Date:  1996-09       Impact factor: 24.094

5.  In-vivo validation of videodensitometric coronary cross-sectional area measurement using dual-energy digital subtraction angiography.

Authors:  S Molloi; A Ersahin; J Hicks; J Wallis
Journal:  Int J Card Imaging       Date:  1995-12

6.  ECG-gated three-dimensional intravascular ultrasound: feasibility and reproducibility of the automated analysis of coronary lumen and atherosclerotic plaque dimensions in humans.

Authors:  C von Birgelen; E A de Vrey; G S Mintz; A Nicosia; N Bruining; W Li; C J Slager; J R Roelandt; P W Serruys; P J de Feyter
Journal:  Circulation       Date:  1997-11-04       Impact factor: 29.690

7.  In vivo validation of the design rules of the coronary arteries and their application in the assessment of diffuse disease.

Authors:  Yifang Zhou; Ghassan S Kassab; Sabee Molloi
Journal:  Phys Med Biol       Date:  2002-03-21       Impact factor: 3.609

8.  Quantitative assessment of coronary vasoreactivity in humans in vivo. Importance of baseline vasomotor tone in atherosclerosis.

Authors:  V Schächinger; A M Zeiher
Journal:  Circulation       Date:  1995-10-15       Impact factor: 29.690

9.  Measurement from arteriograms of regional myocardial bed size distal to any point in the coronary vascular tree for assessing anatomic area at risk.

Authors:  C Seiler; R L Kirkeeide; K L Gould
Journal:  J Am Coll Cardiol       Date:  1993-03-01       Impact factor: 24.094

10.  Constrictor and dilator responses to intracoronary acetylcholine in adjacent segments of the same coronary artery in patients with coronary artery disease. Endothelial function revisited.

Authors:  H el-Tamimi; M Mansour; T J Wargovich; J A Hill; R A Kerensky; C R Conti; C J Pepine
Journal:  Circulation       Date:  1994-01       Impact factor: 29.690

View more
  2 in total

1.  Using multidetector computed tomography in a swine model to assess the effects of sublingual nitroglycerin and intravenous adenosine on epicardial coronary arteries.

Authors:  Wesley A Clarkson; Carlos Santiago Restrepo; Terry D Bauch; Bernard J Rubal
Journal:  Comp Med       Date:  2009-12       Impact factor: 0.982

2.  Elevated oxidative stress and endothelial dysfunction in right coronary artery of right ventricular hypertrophy.

Authors:  Xiao Lu; Charles Q Dang; Xiaomei Guo; Sabee Molloi; Cynthia D Wassall; Marvin D Kemple; Ghassan S Kassab
Journal:  J Appl Physiol (1985)       Date:  2011-03-17
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.