Complications of mesh devices for intraperitoneal umbilical hernia repair: a word of caution.

F E Muysoms1, J Bontinck, P Pletinckx.   

Abstract

Several mesh devices for the treatment of umbilical and other small ventral hernias have become available in recent years. These meshes have a dual layer consisting of a permanent or temporary barrier against adhesion formation between the viscera and the intraperitoneally exposed part of the mesh. We have seen several patients with serious late complications of these meshes placed intraperitoneally. Some of these patients needed small bowel resection and mesh removal. Others developed a recurrence because of improper deployment of the mesh in the intraperitoneal position. We think that, if preperitoneal deployment of such mesh devices is possible, this should be the preferred position, notwithstanding the fact that these meshes have a dual layer. There is a complete lack of convincing data on these mesh devices in the medical literature. No long-term data have been published, and, for three of the four mesh devices available, no publications on their use in humans were found. We think that surgeons adopting innovative mesh devices should register and follow their patients prospectively, at least until there are enough published studies with sufficiently large patient samples, acceptable follow up times, and favourable outcomes.

Entities:  

Mesh:

Year:  2010        PMID: 20556448     DOI: 10.1007/s10029-010-0692-x

Source DB:  PubMed          Journal:  Hernia        ISSN: 1248-9204            Impact factor:   4.739


  11 in total

1.  Spontaneous mesh evacuation per rectum after incisional ventral hernia repair.

Authors:  M Horzic; D Vergles; K Cupurdija; M Kopljar; M Zidak; Z Lackovic
Journal:  Hernia       Date:  2010-03-31       Impact factor: 4.739

2.  Intraperitoneal tension-free repair of small midline ventral abdominal wall hernias with a Ventralex hernia patch: initial experience in 51 patients.

Authors:  H I A Hadi; A Maw; S Sarmah; P Kumar
Journal:  Hernia       Date:  2006-08-24       Impact factor: 4.739

3.  Long-term follow-up after umbilical hernia repair: are there risk factors for recurrence after simple and mesh repair.

Authors:  J A Halm; J Heisterkamp; H F Veen; W F Weidema
Journal:  Hernia       Date:  2005-07-26       Impact factor: 4.739

4.  Randomized clinical trial comparing suture and mesh repair of umbilical hernia in adults.

Authors:  A Arroyo; P García; F Pérez; J Andreu; F Candela; R Calpena
Journal:  Br J Surg       Date:  2001-10       Impact factor: 6.939

5.  Late mesh migration through the stomach wall after laparoscopic refundoplication using a dual-sided PTFE/ePTFE mesh.

Authors:  M Carpelan-Holmström; O Kruuna; J Salo; L Kylänpää; T Scheinin
Journal:  Hernia       Date:  2010-02-04       Impact factor: 4.739

6.  Mesh versus direct suture for the repair of umbilical and epigastric hernias. Ten-year experience.

Authors:  Cesare Stabilini; Mattis Stella; Marco Frascio; Luigi De Salvo; Rosario Fornaro; Giancarlo Larghero; Francesca Mandolfino; Fabrizio Lazzara; Ezio Gianetta
Journal:  Ann Ital Chir       Date:  2009 May-Jun       Impact factor: 0.766

7.  Mesh versus non-mesh repair of ventral abdominal hernias.

Authors:  A M Malik; A Jawaid; A H Talpur; A A Laghari; A Khan
Journal:  J Ayub Med Coll Abbottabad       Date:  2008 Jul-Sep

8.  Open intraperitoneal mesh repair for umbilical hernias. A technical note.

Authors:  E Berrevoet; B de Hemptinne
Journal:  Acta Chir Belg       Date:  2009 Jul-Aug       Impact factor: 1.090

9.  Management of complicated umbilical hernias in cirrhotic patients using permanent mesh: randomized clinical trial.

Authors:  S A Ammar
Journal:  Hernia       Date:  2009-08-29       Impact factor: 4.739

10.  Composite mesh migration into the sigmoid colon following ventral hernia repair.

Authors:  E C Nelson; T J Vidovszky
Journal:  Hernia       Date:  2010-01-08       Impact factor: 4.739

View more
  23 in total

1.  Short-term comparison between preperitoneal and intraperitoneal onlay mesh placement in robotic ventral hernia repair.

Authors:  F Gokcal; S Morrison; O Y Kudsi
Journal:  Hernia       Date:  2019-04-09       Impact factor: 4.739

2.  Lessons and challenges during a 5-year follow-up of 21 Composix Kugel implantations.

Authors:  A Wiegering; N Schlegel; C Isbert; C Jurowich; S Doht; C T Germer; U A Dietz
Journal:  Hernia       Date:  2013-05-09       Impact factor: 4.739

3.  Long-term follow-up after elective adult umbilical hernia repair: low recurrence rates also after non-mesh repairs.

Authors:  J Dalenbäck; C Andersson; D Ribokas; G Rimbäck
Journal:  Hernia       Date:  2012-09-13       Impact factor: 4.739

4.  Parastomal hernia and prophylactic mesh use during primary stoma formation: a commentary.

Authors:  J-B Cornille; I R Daniels; N J Smart
Journal:  Hernia       Date:  2016-06-14       Impact factor: 4.739

5.  Extended totally extraperitoneal Rives-Stoppa (eTEP-RS) technique for ventral hernia: initial experience of The Wall Hernia Group and a surgical technique update.

Authors:  Jacopo Andreuccetti; Alberto Sartori; Enrico Lauro; Lorenzo Crepaz; Silvia Sanna; Giusto Pignata; Umberto Bracale; Alberto Di Leo
Journal:  Updates Surg       Date:  2021-04-30

6.  Single centre observational study to evaluate the safety and efficacy of the Proceed™ Ventral Patch to repair small ventral hernias.

Authors:  J Bontinck; I Kyle-Leinhase; P Pletinckx; V Vergucht; R Beckers; F Muysoms
Journal:  Hernia       Date:  2013-07-24       Impact factor: 4.739

7.  Coated meshes for hernia repair provide comparable intraperitoneal adhesion prevention.

Authors:  Marc H F Schreinemacher; Kevin W Y van Barneveld; Rieky E G Dikmans; Marion J J Gijbels; Jan-Willem M Greve; Nicole D Bouvy
Journal:  Surg Endosc       Date:  2013-06-08       Impact factor: 4.584

8.  Infection and recurrence rates of the C-QUR V-Patch in ventral hernia repairs.

Authors:  D Cheng; L Bonato; C Leinkram
Journal:  Hernia       Date:  2018-06-15       Impact factor: 4.739

9.  Intraperitoneal behaviour of a new composite mesh (Parietex™ Composite Ventral Patch) designed for umbilical or epigastric hernia repair.

Authors:  F García-Moreno; S Sotomayor; P Pérez-López; B Pérez-Köhler; Y Bayon; G Pascual; J M Bellón
Journal:  Surg Endosc       Date:  2014-06-27       Impact factor: 4.584

10.  Sutured repair of primary small umbilical and epigastric hernias: concomitant rectus diastasis is a significant risk factor for recurrence.

Authors:  Gernot Köhler; Ruzica-Rosalia Luketina; Klaus Emmanuel
Journal:  World J Surg       Date:  2015-01       Impact factor: 3.352

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.