Literature DB >> 20541438

Quality control based on isotopic distributions for high-throughput MALDI-TOF and MALDI-FTICR serum peptide profiling.

Simone Nicolardi1, Magnus Palmblad, Hans Dalebout, Marco Bladergroen, Rob A E M Tollenaar, André M Deelder, Yuri E M van der Burgt.   

Abstract

In this study, we have implemented a new quality control (QC) parameter for peptide profiling based on isotopic distributions. This QC parameter is an objective measure and facilitates automatic sorting of large numbers of peptide spectra. Peptides in human serum samples were enriched using reversed-phase C(18)-functionalized magnetic beads using a high-throughput robotic platform. High-resolution MALDI-TOF and ultrahigh resolution MALDI-FTICR mass spectra were obtained and a workflow was developed for automated analysis and evaluation of these profiles. To this end, the isotopic distributions of multiple peptides were quantified from both MALDI-TOF and MALDI-FTICR spectra. Odd peptide isotope distributions in TOF spectra could be rationalized from ultrahigh resolution FTICR spectra that showed overlap of different peptides. The comparison of isotope patterns with estimated polyaveragine distributions was used to calculate a QC value for each single mass spectrum. Sorting these QC values enabled the best MALDI spectrum to be selected from replicate spots. Moreover, using this approach spectra containing high intensities of polymers or other contaminants and lacking peptides of interest can be efficiently removed from a clinical dataset. In general, this method simplifies the exclusion of low quality spectra from further statistical analysis. 2010 American Society for Mass Spectrometry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20541438     DOI: 10.1016/j.jasms.2010.05.004

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  47 in total

1.  Reliability of human serum protein profiles generated with C8 magnetic beads assisted MALDI-TOF mass spectrometry.

Authors:  Mirre E de Noo; Rob A E M Tollenaar; Aliye Ozalp; Peter J K Kuppen; Marco R Bladergroen; Paul H C Eilers; André M Deelder
Journal:  Anal Chem       Date:  2005-11-15       Impact factor: 6.986

2.  Efficient calculation of accurate masses of isotopic peaks.

Authors:  Alan L Rockwood; Perttu Haimi
Journal:  J Am Soc Mass Spectrom       Date:  2006-02-03       Impact factor: 3.109

Review 3.  Reproducibility in protein profiling by MALDI-TOF mass spectrometry.

Authors:  Jakob Albrethsen
Journal:  Clin Chem       Date:  2007-03-29       Impact factor: 8.327

Review 4.  Serum protein profiling by solid phase extraction and mass spectrometry: a future diagnostics tool?

Authors:  Anne K Callesen; Jonna S Madsen; Werner Vach; Torben A Kruse; Ole Mogensen; Ole N Jensen
Journal:  Proteomics       Date:  2009-03       Impact factor: 3.984

5.  Determination of monoisotopic masses and ion populations for large biomolecules from resolved isotopic distributions.

Authors:  M W Senko; S C Beu; F W McLaffertycor
Journal:  J Am Soc Mass Spectrom       Date:  1995-04       Impact factor: 3.109

6.  Use of proteomic patterns in serum to identify ovarian cancer.

Authors:  Emanuel F Petricoin; Ali M Ardekani; Ben A Hitt; Peter J Levine; Vincent A Fusaro; Seth M Steinberg; Gordon B Mills; Charles Simone; David A Fishman; Elise C Kohn; Lance A Liotta
Journal:  Lancet       Date:  2002-02-16       Impact factor: 79.321

7.  Detection of colorectal cancer using MALDI-TOF serum protein profiling.

Authors:  Mirre E de Noo; Bart J A Mertens; Aliye Ozalp; Marco R Bladergroen; Martijn P J van der Werff; Cornelis J H van de Velde; Andre M Deelder; Rob A E M Tollenaar
Journal:  Eur J Cancer       Date:  2006-04-17       Impact factor: 9.162

8.  MALDI TOF-TOF characterization of a light stabilizer polymer contaminant from polypropylene or polyethylene plastic test tubes.

Authors:  Emmanuelle Sachon; Lucrèce Matheron; Gilles Clodic; Thierry Blasco; Gérard Bolbach
Journal:  J Mass Spectrom       Date:  2010-01       Impact factor: 1.982

9.  Collisions or electrons? Protein sequence analysis in the 21st century.

Authors:  Joshua J Coon
Journal:  Anal Chem       Date:  2009-05-01       Impact factor: 6.986

Review 10.  Sample preparation for serum/plasma profiling and biomarker identification by mass spectrometry.

Authors:  Jose L Luque-Garcia; Thomas A Neubert
Journal:  J Chromatogr A       Date:  2006-12-12       Impact factor: 4.759

View more
  8 in total

1.  Comparison of the Mahalanobis distance and Pearson's χ² statistic as measures of similarity of isotope patterns.

Authors:  Fatemeh Zamanzad Ghavidel; Jürgen Claesen; Tomasz Burzykowski; Dirk Valkenborg
Journal:  J Am Soc Mass Spectrom       Date:  2013-11-19       Impact factor: 3.109

2.  Serum peptide signatures for pancreatic cancer based on mass spectrometry: a comparison to CA19-9 levels and routine imaging techniques.

Authors:  Berit Velstra; Marieke A Vonk; Bert A Bonsing; Bart J Mertens; Simone Nicolardi; Anouck Huijbers; Hans Vasen; André M Deelder; Wilma E Mesker; Yuri E M van der Burgt; Rob A E M Tollenaar
Journal:  J Cancer Res Clin Oncol       Date:  2014-09-21       Impact factor: 4.553

3.  Improved classification of breast cancer peptide and protein profiles by combining two serum workup procedures.

Authors:  Berit Velstra; Yuri E M van der Burgt; Bart J Mertens; Wilma E Mesker; André M Deelder; Rob A E M Tollenaar
Journal:  J Cancer Res Clin Oncol       Date:  2012-07-05       Impact factor: 4.553

4.  Mesoporous silica chip: enabled peptide profiling as an effective platform for controlling bio-sample quality and optimizing handling procedure.

Authors:  Kai Liang; Hongmei Wu; Tony Y Hu; Yan Li
Journal:  Clin Proteomics       Date:  2016-11-22       Impact factor: 3.988

5.  Lactococcus lactis as a safe and inexpensive source of bioactive silver composites.

Authors:  Railean-Plugaru Viorica; Pomastowski Pawel; Meller Kinga; Złoch Michal; Rafinska Katarzyna; Buszewski Boguslaw
Journal:  Appl Microbiol Biotechnol       Date:  2017-08-25       Impact factor: 4.813

6.  Enzymatic Cascades for Tailored 13C6 and 15N Enriched Human Milk Oligosaccharides.

Authors:  Thomas Fischöder; Samanta Cajic; Valerian Grote; Raphael Heinzler; Udo Reichl; Matthias Franzreb; Erdmann Rapp; Lothar Elling
Journal:  Molecules       Date:  2019-09-25       Impact factor: 4.411

7.  Analysis of Synthetic Monodisperse Polysaccharides by Wide Mass Range Ultrahigh-Resolution MALDI Mass Spectrometry.

Authors:  Simone Nicolardi; A Abragam Joseph; Qian Zhu; Zhengnan Shen; Alonso Pardo-Vargas; Fabrizio Chiodo; Antonio Molinaro; Alba Silipo; Yuri E M van der Burgt; Biao Yu; Peter H Seeberger; Manfred Wuhrer
Journal:  Anal Chem       Date:  2021-03-05       Impact factor: 6.986

8.  Physicochemical study of natural fractionated biocolloid by asymmetric flow field-flow fractionation in tandem with various complementary techniques using biologically synthesized silver nanocomposites.

Authors:  Viorica Railean-Plugaru; Pawel Pomastowski; Tomasz Kowalkowski; Myroslav Sprynskyy; Boguslaw Buszewski
Journal:  Anal Bioanal Chem       Date:  2018-04-03       Impact factor: 4.142

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.