Abstract

PURPOSE: To evaluate the diagnostic ability of macular parameters and peripapillary retinal nerve fiber layer (RNFL) parameters for early glaucoma using spectral domain optical coherence tomography (SD-OCT).
MATERIALS AND METHODS: One eye from 32 early glaucoma patients (including preperimetric glaucoma) and 32 normal participants underwent macular scans and peripapillary RNFL scans with SD-OCT 3 times on the same day. The discrimination power of each parameter to detect early glaucoma was determined by areas under receiver operating characteristics curve (AROC) and sensitivity at fixed specificity. Correlation of OCT data with visual field defects was evaluated by linear regression analysis. Reproducibility was also evaluated.
RESULTS: Significant differences between early glaucoma and normal participants were found for all parameters except fovea in macular scans and in the superior and inferior quadrants, at 12, 3, 6, 7, 11 o'clock, and average RNFL thickness in RNFL scans. The best parameters based on AROC and sensitivity at a specificity of >90% were temporal outer macula thickness (AROC, 0.79; sensitivity, 63%) in macular parameters and inferior quadrant (AROC, 0.82; sensitivity, 53%) in RNFL parameters. The highest correlation with mean deviation was found in inferior inner macular volume (r=0.50, P<0.001). The mean intraclass correlation coefficient was 0.96 in macular scans and 0.84 in RNFL scans. Test-retest variability ranged from 2.3 to 10.1 μm in macular thickness, 0 to 0.06 mm in macular volume, and 5.8 to 18.9 μm in RNFL thickness.
CONCLUSION: For the diagnosis of early glaucoma by SD-OCT, macular parameters had high discriminating power and high reproducibility comparable with peripapillary RNFL parameters.

Entities:  

Mesh:

Year:  2011        PMID: 20520570     DOI: 10.1097/IJG.0b013e3181e079ed

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  57 in total

1.  Asymmetry in hemifield macular thickness as an early indicator of glaucomatous change.

Authors:  Tae Woong Um; Kyung Rim Sung; Gadi Wollstein; Sung-Cheol Yun; Jung Hwa Na; Joel S Schuman
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-03-02       Impact factor: 4.799

2.  2-D pattern of nerve fiber bundles in glaucoma emerging from spectral-domain optical coherence tomography.

Authors:  Mona K Garvin; Michael D Abràmoff; Kyungmoo Lee; Meindert Niemeijer; Milan Sonka; Young H Kwon
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-01-31       Impact factor: 4.799

3.  Comparison of macular ganglion cell complex thickness to total retinal thickness ratio between Hungarian and Japanese eyes.

Authors:  Yoshiyuki Kita; Farzaneh Naghizadeh; Ritsuko Kita; Goji Tomita; Gábor Holló
Journal:  Jpn J Ophthalmol       Date:  2013-08-27       Impact factor: 2.447

4.  Diagnostic performance and reproducibility of circumpapillary retinal nerve fiber layer thickness measurement in 10-degree sectors in early stage glaucoma.

Authors:  Hiroyo Hirasawa; Chihiro Mayama; Atsuo Tomidokoro; Makoto Araie; Aiko Iwase; Kazuhisa Sugiyama; Shoji Kishi; Naoyuki Maeda; Nagahisa Yoshimura
Journal:  Jpn J Ophthalmol       Date:  2014-12-19       Impact factor: 2.447

5.  Comparison of the current and a new RTVue OCT software version for detection of ganglion cell complex changes due to cataract surgery.

Authors:  Gábor Holló; Farzaneh Naghizadeh; Sofia Hsu; Tamás Filkorn; Mária Bausz
Journal:  Int Ophthalmol       Date:  2015-03-27       Impact factor: 2.031

Review 6.  Test-retest variability in structural parameters measured with glaucoma imaging devices.

Authors:  Makoto Araie
Journal:  Jpn J Ophthalmol       Date:  2012-11-09       Impact factor: 2.447

7.  Diagnostic capability of peripapillary retinal thickness in glaucoma using 3D volume scans.

Authors:  Huseyin Simavli; Christian John Que; Mustafa Akduman; Jennifer L Rizzo; Edem Tsikata; Johannes F de Boer; Teresa C Chen
Journal:  Am J Ophthalmol       Date:  2014-12-09       Impact factor: 5.258

8.  Intraocular retinal thickness asymmetry in early stage of primary open angle glaucoma and normal tension glaucoma.

Authors:  Pei-Wen Lin; Hsueh-Wen Chang; Ing-Chou Lai; Jen-Chia Tsai; Yi-Chieh Poon
Journal:  Int J Ophthalmol       Date:  2018-08-18       Impact factor: 1.779

9.  Use of Fourier-domain OCT to detect retinal nerve fiber layer degeneration in Parkinson's disease patients.

Authors:  M Satue; E Garcia-Martin; I Fuertes; S Otin; R Alarcia; R Herrero; M P Bambo; L E Pablo; F J Fernandez
Journal:  Eye (Lond)       Date:  2013-02-22       Impact factor: 3.775

Review 10.  Optic nerve head and fibre layer imaging for diagnosing glaucoma.

Authors:  Manuele Michelessi; Ersilia Lucenteforte; Francesco Oddone; Miriam Brazzelli; Mariacristina Parravano; Sara Franchi; Sueko M Ng; Gianni Virgili
Journal:  Cochrane Database Syst Rev       Date:  2015-11-30