Literature DB >> 25813376

Comparison of the current and a new RTVue OCT software version for detection of ganglion cell complex changes due to cataract surgery.

Gábor Holló1, Farzaneh Naghizadeh2, Sofia Hsu2,3, Tamás Filkorn2, Mária Bausz2.   

Abstract

The purpose was to compare the current (6.3) and a novel software version (6.12) of the RTVue-100 optical coherence tomograph (RTVue OCT) for ganglion cell complex (GCC) and retinal nerve fibre layer thickness (RNFLT) changes after phacoemulsification in healthy cataract eyes, and to investigate whether version 6.12, in which image segmentation is improved, provides benefits over version 6.3 for RNFLT and GCC imaging via mild cataract. One eye of 22 consecutive healthy cataract patients were imaged before and 1 month after uncomplicated cataract surgery using RTVue-100 OCT software version 6.3. The images were analysed with both software versions. Signal strength index increased significantly after surgery for both RNFLT and the GCC measurements (p ≤ 0.0015). No difference was seen for any RNFLT parameter between the software versions and time points (p ≥ 0.0140). The GCC values did not differ between the versions either before or after surgery (p ≥ 0.4471), but all increased significantly after surgery with software version 6.12 (p < 0.0001). Neither focal loss volume (FLV) nor global loss volume (GLV) differed between the software versions before and after surgery, respectively, but GLV decreased (improved) significantly after surgery (p = 0.010 and <0.001 for versions 6.3 and 6.12, respectively). Cataract surgery induced similar changes with both software versions, but version 6.12 identified the increase of GCC thickness and the decrease of GLV better than the current version. Although no significant difference between software versions was seen before surgery, our results suggest that version 6.12 may be more precise in measuring GCC parameters than the currently available version.

Entities:  

Keywords:  Cataract surgery; Ganglion cell complex; RTVue-100 Fourier-domain optical coherence tomography; Retinal nerve fibre layer thickness; Signal-to-noise ratio

Mesh:

Year:  2015        PMID: 25813376     DOI: 10.1007/s10792-015-0064-8

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  23 in total

1.  Evaluation of macular thickness and peripapillary retinal nerve fiber layer thickness for detection of early glaucoma using spectral domain optical coherence tomography.

Authors:  Yusuke Nakatani; Tomomi Higashide; Shinji Ohkubo; Hisashi Takeda; Kazuhisa Sugiyama
Journal:  J Glaucoma       Date:  2011 Apr-May       Impact factor: 2.503

2.  Influence of cataract on time domain and spectral domain optical coherence tomography retinal nerve fiber layer measurements.

Authors:  Na Rae Kim; Hun Lee; Eun Suk Lee; Ji Hyun Kim; Samin Hong; Gong Je Seong; Chan Yun Kim
Journal:  J Glaucoma       Date:  2012-02       Impact factor: 2.503

3.  Macular ganglion cell/inner plexiform layer measurements by spectral domain optical coherence tomography for detection of early glaucoma and comparison to retinal nerve fiber layer measurements.

Authors:  Kouros Nouri-Mahdavi; Sara Nowroozizadeh; Nariman Nassiri; Nila Cirineo; Shane Knipping; Joann Giaconi; Joseph Caprioli
Journal:  Am J Ophthalmol       Date:  2013-09-25       Impact factor: 5.258

4.  Diagnostic accuracy of nerve fibre layer, macular thickness and optic disc measurements made with the RTVue-100 optical coherence tomograph to detect glaucoma.

Authors:  A Garas; P Vargha; G Holló
Journal:  Eye (Lond)       Date:  2010-10-08       Impact factor: 3.775

5.  The effect of phacoemulsification cataract surgery on polarimetry and tomography measurements for glaucoma diagnosis.

Authors:  Ana Sánchez-Cano; Luis E Pablo; José Manuel Larrosa; Vicente Polo
Journal:  J Glaucoma       Date:  2010-09       Impact factor: 2.503

6.  Macular and peripapillary retinal nerve fiber layer measurements by spectral domain optical coherence tomography in normal-tension glaucoma.

Authors:  Mincheol Seong; Kyung Rim Sung; Eun Hee Choi; Sung Yong Kang; Jung Woo Cho; Tae Woong Um; Yoon Jeon Kim; Seong Bae Park; Hun Eui Hong; Michael S Kook
Journal:  Invest Ophthalmol Vis Sci       Date:  2009-10-15       Impact factor: 4.799

7.  Influence of a new software version of the RTVue-100 optical coherence tomograph on ganglion cell complex segmentation in various forms of age-related macular degeneration.

Authors:  Gábor Holló; Farzaneh Naghizadeh
Journal:  J Glaucoma       Date:  2015-03       Impact factor: 2.503

8.  Detection of macular ganglion cell loss in glaucoma by Fourier-domain optical coherence tomography.

Authors:  Ou Tan; Vikas Chopra; Ake Tzu-Hui Lu; Joel S Schuman; Hiroshi Ishikawa; Gadi Wollstein; Rohit Varma; David Huang
Journal:  Ophthalmology       Date:  2009-09-10       Impact factor: 12.079

9.  Diagnostic validity of macular ganglion cell-inner plexiform layer thickness deviation map algorithm using cirrus HD-OCT in preperimetric and early glaucoma.

Authors:  Mi-Sun Sung; Jin-Ha Yoon; Sang-Woo Park
Journal:  J Glaucoma       Date:  2014 Oct-Nov       Impact factor: 2.503

10.  Foveal thickness after phacoemulsification as measured by optical coherence tomography.

Authors:  Gerasimos Th Georgopoulos; Dimitrios Papaconstantinou; Maria Niskopoulou; Marilita Moschos; Ilias Georgalas; Chrysanthi Koutsandrea
Journal:  Clin Ophthalmol       Date:  2008-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.