Literature DB >> 20516328

Early failure of a modular femoral neck total hip arthroplasty component: a case report.

David A J Wilson1, Michael J Dunbar, John D Amirault, Zoheir Farhat.   

Abstract

Entities:  

Mesh:

Year:  2010        PMID: 20516328     DOI: 10.2106/JBJS.I.01107

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


× No keyword cloud information.
  15 in total

1.  Long-term survivorship and complication rate comparison of a cementless modular stem and cementless fixed neck stems for primary total hip replacement.

Authors:  David A Fitch; Cristina Ancarani; Barbara Bordini
Journal:  Int Orthop       Date:  2015-07-09       Impact factor: 3.075

2.  What Factors Are Associated With Neck Fracture in One Commonly Used Bimodular THA Design? A Multicenter, Nationwide Study in Slovenia.

Authors:  Simon Kovač; Blaž Mavčič; Marko Kotnik; Vesna Levašič; Mateja Sirše; Samo Karel Fokter
Journal:  Clin Orthop Relat Res       Date:  2019-06       Impact factor: 4.176

3.  New technology: safety, efficacy, and learning curves.

Authors:  Paul J Duwelius; Javad Parvizi; Laura Matsen Ko
Journal:  Clin Orthop Relat Res       Date:  2013-12-07       Impact factor: 4.176

4.  Stem-Sleeve Junction Failure of a Modular Femoral Hip System: a Retrieval Analysis.

Authors:  Feras Waly; Fahad H Abduljabbar; Trevor Gascoyne; Thomas R Turgeon; Olga Huk
Journal:  HSS J       Date:  2015-07-09

5.  Result of Modular Necks in Primary Total Hip Arthroplasty with a Average Follow-up of Four Years.

Authors:  Jemin Yi; Kye Young Han; Young Jun Nam; Keun Woo Kim
Journal:  Hip Pelvis       Date:  2016-09-30

6.  Mechanical failure of total hip arthroplasties and associated risk factors.

Authors:  Henrik C Bäcker; Chia H Wu; Arne Kienzle; Carsten Perka; Clemens Gwinner
Journal:  Arch Orthop Trauma Surg       Date:  2022-01-28       Impact factor: 3.067

7.  Effect of femoral neck modularity upon the prosthetic range of motion in total hip arthroplasty.

Authors:  Glen A Turley; Damian R Griffin; Mark A Williams
Journal:  Med Biol Eng Comput       Date:  2014-06-27       Impact factor: 2.602

8.  Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck.

Authors:  H John Cooper; Robert M Urban; Richard L Wixson; R Michael Meneghini; Joshua J Jacobs
Journal:  J Bone Joint Surg Am       Date:  2013-05-15       Impact factor: 5.284

9.  Modular versus nonmodular neck femoral implants in primary total hip arthroplasty: which is better?

Authors:  Paul J Duwelius; Bob Burkhart; Clay Carnahan; Grant Branam; Laura Matsen Ko; Yingxing Wu; Cecily Froemke; Lian Wang; Gary Grunkemeier
Journal:  Clin Orthop Relat Res       Date:  2013-11-02       Impact factor: 4.176

10.  A case of a C-stem fracture at the head-neck junction and a review of the literature.

Authors:  David Morley; Ian Starks; Justin Lim
Journal:  Case Rep Orthop       Date:  2012-12-09
View more