Literature DB >> 20515308

Insulin patch pumps: their development and future in closed-loop systems.

Henry Anhalt1, Nancy J V Bohannon.   

Abstract

Steady progress is being made toward the development of a so-called "artificial pancreas," which may ultimately be a fully automated, closed-loop, glucose control system comprising a continuous glucose monitor, an insulin pump, and a controller. The controller will use individualized algorithms to direct delivery of insulin without user input. A major factor propelling artificial pancreas development is the substantial incidence of-and attendant patient, parental, and physician concerns about-hypoglycemia and extreme hyperglycemia associated with current means of insulin delivery for type 1 diabetes mellitus (T1DM). A successful fully automated artificial pancreas would likely reduce the frequency of and anxiety about hypoglycemia and marked hyperglycemia. Patch-pump systems ("patch pumps") are likely to be used increasingly in the control of T1DM and may be incorporated into the artificial pancreas systems of tomorrow. Patch pumps are free of tubing, small, lightweight, and unobtrusive. This article describes features of patch pumps that have been approved for U.S. marketing or are under development. Included in the review is an introduction to control algorithms driving insulin delivery, particularly the two major types: proportional integrative derivative and model predictive control. The use of advanced algorithms in the clinical development of closed-loop systems is reviewed along with projected next steps in artificial pancreas development.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20515308      PMCID: PMC2924780          DOI: 10.1089/dia.2010.0016

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  29 in total

1.  Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes.

Authors:  David M Nathan; Patricia A Cleary; Jye-Yu C Backlund; Saul M Genuth; John M Lachin; Trevor J Orchard; Philip Raskin; Bernard Zinman
Journal:  N Engl J Med       Date:  2005-12-22       Impact factor: 91.245

Review 2.  The future of continuous glucose monitoring: closed loop.

Authors:  Roman Hovorka
Journal:  Curr Diabetes Rev       Date:  2008-08

3.  The British Diabetic Association Cohort Study, II: cause-specific mortality in patients with insulin-treated diabetes mellitus.

Authors:  S P Laing; A J Swerdlow; S D Slater; J L Botha; A C Burden; N R Waugh; A W Smith; R D Hill; P J Bingley; C C Patterson; Z Qiao; H Keen
Journal:  Diabet Med       Date:  1999-06       Impact factor: 4.359

4.  Feasibility of automating insulin delivery for the treatment of type 1 diabetes.

Authors:  Garry M Steil; Kerstin Rebrin; Christine Darwin; Farzam Hariri; Mohammed F Saad
Journal:  Diabetes       Date:  2006-12       Impact factor: 9.461

5.  Model predictive control of type 1 diabetes: an in silico trial.

Authors:  Lalo Magni; Davide M Raimondo; Luca Bossi; Chiara Dalla Man; Giuseppe De Nicolao; Boris Kovatchev; Claudio Cobelli
Journal:  J Diabetes Sci Technol       Date:  2007-11

6.  Parental fear of hypoglycemia: young children treated with continuous subcutaneous insulin infusion.

Authors:  Susana R Patton; Lawrence M Dolan; Racquel Henry; Scott W Powers
Journal:  Pediatr Diabetes       Date:  2007-12       Impact factor: 4.866

7.  Is an automatic pump suspension feature safe for children with type 1 diabetes? An exploratory analysis with a closed-loop system.

Authors:  Eda Cengiz; Karena L Swan; William V Tamborlane; Garry M Steil; Amy T Steffen; Stuart A Weinzimer
Journal:  Diabetes Technol Ther       Date:  2009-04       Impact factor: 6.118

Review 8.  Sensor-augmented pump therapy in type 1 diabetes.

Authors:  Stuart A Weinzimer; William V Tamborlane
Journal:  Curr Opin Endocrinol Diabetes Obes       Date:  2008-04       Impact factor: 3.243

Review 9.  Severe hypoglycaemia and glycaemic control in Type 1 diabetes: meta-analysis of multiple daily insulin injections compared with continuous subcutaneous insulin infusion.

Authors:  J C Pickup; A J Sutton
Journal:  Diabet Med       Date:  2008-07       Impact factor: 4.359

10.  In silico evaluation platform for artificial pancreatic beta-cell development--a dynamic simulator for closed-loop control with hardware-in-the-loop.

Authors:  Eyal Dassau; Cesar C Palerm; Howard Zisser; Bruce A Buckingham; Lois Jovanovic; Francis J Doyle
Journal:  Diabetes Technol Ther       Date:  2009-03       Impact factor: 6.118

View more
  17 in total

1.  Patch pump versus conventional pump: postprandial glycemic excursions and the influence of wear time.

Authors:  Yoeri M Luijf; Sabine Arnolds; Angelo Avogaro; Carsten Benesch; Daniela Bruttomesso; Anne Farret; Lutz Heinemann; Jerome Place; Eric Renard; Rachele Scotton; J Hans DeVries
Journal:  Diabetes Technol Ther       Date:  2013-05-07       Impact factor: 6.118

Review 2.  New-generation diabetes management: glucose sensor-augmented insulin pump therapy.

Authors:  Eda Cengiz; Jennifer L Sherr; Stuart A Weinzimer; William V Tamborlane
Journal:  Expert Rev Med Devices       Date:  2011-07       Impact factor: 3.166

Review 3.  Management of diabetes mellitus: is the pump mightier than the pen?

Authors:  John C Pickup
Journal:  Nat Rev Endocrinol       Date:  2012-02-28       Impact factor: 43.330

4.  Accuracy of a new patch pump based on a microelectromechanical system (MEMS) compared to other commercially available insulin pumps: results of the first in vitro and in vivo studies.

Authors:  Sophie Borot; Sylvia Franc; Justine Cristante; Alfred Penfornis; Pierre-Yves Benhamou; Bruno Guerci; Hélène Hanaire; Eric Renard; Yves Reznik; Chantal Simon; Guillaume Charpentier
Journal:  J Diabetes Sci Technol       Date:  2014-07-30

5.  Patch Pumps: Are They All the Same?

Authors:  Lutz Heinemann; Delia Waldenmaier; Bernd Kulzer; Ralph Ziegler; Barry Ginsberg; Guido Freckmann
Journal:  J Diabetes Sci Technol       Date:  2018-08-22

6.  Stabilized glucagon formulation for bihormonal pump use.

Authors:  Solomon S Steiner; Ming Li; Robert Hauser; Roderike Pohl
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

7.  Patient Perceptions and Preferences for a Mealtime Insulin Delivery Patch.

Authors:  Mark Peyrot; Darlene Dreon; Vivien Zraick; Brett Cross; Meng H Tan
Journal:  Diabetes Ther       Date:  2018-01-11       Impact factor: 2.945

8.  Clinical utility of insulin and insulin analogs.

Authors:  Ahter D Sanlioglu; Hasan Ali Altunbas; Mustafa Kemal Balci; Thomas S Griffith; Salih Sanlioglu
Journal:  Islets       Date:  2013-03-01       Impact factor: 2.694

9.  Challenges and Recent Progress in the Development of a Closed-loop Artificial Pancreas.

Authors:  B Wayne Bequette
Journal:  Annu Rev Control       Date:  2012-12       Impact factor: 6.091

Review 10.  Evaluation of hypoglycemic therapeutics and nutritional supplementation for type 2 diabetes mellitus management: An insight on molecular approaches.

Authors:  Murugan Prasathkumar; Robert Becky; Salim Anisha; Chenthamara Dhrisya; Subramaniam Sadhasivam
Journal:  Biotechnol Lett       Date:  2022-02-04       Impact factor: 2.461

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.