Literature DB >> 20512438

Incidence and factors associated with squeaking in alumina-on-alumina THA.

Il-Yong Choi1, Yee-Suk Kim, Kyu-Tae Hwang, Young-Ho Kim.   

Abstract

BACKGROUND: The alumina-on-alumina bearing surface, which has a high wear resistance and a good biocompatibility, is widely used in THA but recently has been associated with squeaking. While various authors have reported factors associated with squeaking, they remain poorly understood. QUESTIONS/PURPOSES: To contribute to the debate on squeaking we therefore asked the following questions: (1) What is the incidence of squeaking in alumina-on-alumina THA? (2) What factors are associated with squeaking in alumina bearings in our practice?
METHODS: We retrospectively reviewed 168 patients (173 hips) who had primary alumina-on-alumina THAs. The mean age of the patients was 53 years (range, 18 to 81 years). Minimum followup was 5.6 years (average, 7.3 years; range, 5.6-9.4 years). All patients were evaluated clinically and radiographically with attention to periprosthetic osteolysis, squeaking, and ceramic fracture. When the patient reported squeaking, we determined the onset, reproducibility, and activities associated with the squeaking. We recorded patient (gender, age, height, weight, and body mass index) and surgical factors (abduction angle of cup, size and length of ceramic head component, and diameter of cup in the implant).
RESULTS: Eight of the 168 patients (5%) had squeaking hips. Squeaking was more common in males and in those with large ceramic heads. There were no complications or revisions in the squeaking group. One ceramic liner fracture was associated with trochanteric nonunion.
CONCLUSIONS: When recommending alumina-on-alumina bearing surfaces to patients they should be clearly informed of the possibility of squeaking. Patients with risk factors for squeaking should be followed at regular intervals.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20512438      PMCID: PMC2974873          DOI: 10.1007/s11999-010-1394-5

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  40 in total

1.  Ceramic hip prostheses in young patients: a retrospective study of 74 patients.

Authors:  J Fenollosa; P Seminario; C Montijano
Journal:  Clin Orthop Relat Res       Date:  2000-10       Impact factor: 4.176

Review 2.  Wear and periprosthetic osteolysis: the problem.

Authors:  W H Harris
Journal:  Clin Orthop Relat Res       Date:  2001-12       Impact factor: 4.176

3.  Ceramic-on-ceramic bearings in total hip arthroplasty.

Authors:  Benjamin E Bierbaum; James Nairus; Daniel Kuesis; J Craig Morrison; Daniel Ward
Journal:  Clin Orthop Relat Res       Date:  2002-12       Impact factor: 4.176

4.  The 2009 Frank Stinchfield Award: "Hip squeaking": a biomechanical study of ceramic-on-ceramic bearing surfaces.

Authors:  Christophe Chevillotte; Robert T Trousdale; Qingshan Chen; Olivier Guyen; Kai-Nan An
Journal:  Clin Orthop Relat Res       Date:  2009-06-19       Impact factor: 4.176

5.  Mismatched wear couple zirconium oxide and aluminum oxide in total hip arthroplasty.

Authors:  M Morlock; R Nassutt; R Janssen; G Willmann; M Honl
Journal:  J Arthroplasty       Date:  2001-12       Impact factor: 4.757

6.  Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study.

Authors:  Moussa Hamadouche; Pierre Boutin; Jacques Daussange; Mark E Bolander; Laurent Sedel
Journal:  J Bone Joint Surg Am       Date:  2002-01       Impact factor: 5.284

7.  Prevention of wear and osteolysis: alumina-on-alumina bearing.

Authors:  P Bizot; R Nizard; M Hamadouche; D Hannouche; L Sedel
Journal:  Clin Orthop Relat Res       Date:  2001-12       Impact factor: 4.176

8.  Press-fit metal-backed alumina sockets: a minimum 5-year followup study.

Authors:  P Bizot; M Larrouy; J Witvoet; L Sedel; R Nizard
Journal:  Clin Orthop Relat Res       Date:  2000-10       Impact factor: 4.176

9.  Incidence of 'squeaking' after ceramic-on-ceramic total hip arthroplasty.

Authors:  Kenny Mai; Christopher Verioti; Kace A Ezzet; Steven N Copp; Richard H Walker; Clifford W Colwell
Journal:  Clin Orthop Relat Res       Date:  2010-02       Impact factor: 4.176

10.  New experience with alumina-on-alumina ceramic bearings for total hip arthroplasty.

Authors:  James D'Antonio; William Capello; Michael Manley; Benjamin Bierbaum
Journal:  J Arthroplasty       Date:  2002-06       Impact factor: 4.757

View more
  11 in total

1.  Squeaking: Current knowledge and how to avoid it.

Authors:  Arjuna M Imbuldeniya; Simon J Pearce; William L Walter; Bernard A Zicat; William K Walter
Journal:  Curr Rev Musculoskelet Med       Date:  2013-12

2.  The natural history of ceramic-on-ceramic prosthetic hip squeak and its impact on patients.

Authors:  David Owen; Nicholas Russell; Andrew Chia; Malcolm Thomas
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-12-09

3.  Do alumina matrix composite bearings decrease hip noises and bearing fractures at a minimum of 5 years after THA?

Authors:  Seung-Hoon Baek; Won Keun Kim; Jun Young Kim; Shin-Yoon Kim
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

4.  Meta-analysis of the Incidence and Risk Factors for Squeaking after Primary Ceramic-on-ceramic Total Hip Arthroplasty in Asian Patients.

Authors:  Tae-Hun Lee; Young-Wan Moon; Seung-Jae Lim; Youn-Soo Park
Journal:  Hip Pelvis       Date:  2014-06-30

5.  Natural history of noise and squeaking in cementless ceramic-on-ceramic total hip arthroplasty.

Authors:  Kenta Inagaki; Satoshi Iida; Shuichi Miyamoto; Chiho Suzuki; Takushi Nakatani; Yoshiyuki Shinada; Yuya Kawarai; Shigeo Hagiwara; Junichi Nakamura; Sumihisa Orita; Seiji Ohtori
Journal:  J Orthop       Date:  2020-09-19

Review 6.  Review on squeaking hips.

Authors:  Yadin David Levy; Selin Munir; Shane Donohoo; William Lindsay Walter
Journal:  World J Orthop       Date:  2015-11-18

Review 7.  Ceramic-Ceramic Bearing: Too Unpredictable to Use it Regularly.

Authors:  Edwin P Su
Journal:  HSS J       Date:  2012-09-05

Review 8.  Surface Texturing of Prosthetic Hip Implant Bearing Surfaces: A Review.

Authors:  Quentin Allen; Bart Raeymaekers
Journal:  J Tribol       Date:  2020-10-05       Impact factor: 2.045

Review 9.  Fracture of ceramic bearing surfaces following total hip replacement: a systematic review.

Authors:  Francesco Traina; Marcello De Fine; Alberto Di Martino; Cesare Faldini
Journal:  Biomed Res Int       Date:  2013-06-13       Impact factor: 3.411

Review 10.  Hip Squeaking after Ceramic-on-ceramic Total Hip Arthroplasty.

Authors:  Guo-Liang Wu; Wei Zhu; Yan Zhao; Qi Ma; Xi-Sheng Weng
Journal:  Chin Med J (Engl)       Date:  2016-08-05       Impact factor: 2.628

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.