Literature DB >> 12461368

Ceramic-on-ceramic bearings in total hip arthroplasty.

Benjamin E Bierbaum1, James Nairus, Daniel Kuesis, J Craig Morrison, Daniel Ward.   

Abstract

The ideal bearing surface for total hip arthroplasty still is being sought. This bearing would be durable, cost-effective, easy to implant, inert, and produce minimal wear debris. Ceramic-on-ceramic bearings have continued to evolve and have enjoyed success in many European centers throughout the past 3 decades. A limited number of early reports from the United States discouraged widespread acceptance and use of ceramic-on-ceramic total hip arthroplasty. Once critically analyzed most of the failures from the early reports are attributable to design and material specific flaws. Vast improvements have been made in ceramic manufacturing leading to even more superior wear characteristics and higher burst strengths. The case for alumina-on-alumina ceramic bearings is becoming stronger as data accumulate clinically and in vitro. In a multicenter, prospective and randomized study, an alumina-on-alumina ceramic bearing is compared with a cobalt chrome-on-polyethylene bearing. After as many as 48 months there has been no significant difference in clinical performance between the two study groups. No ceramic head fracture or ceramic bearing failure has occurred. Therefore, this new alumina-on-alumina ceramic bearing is a safe option for total hip arthroplasty and may provide a more durable prosthesis especially in young and active patients.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12461368     DOI: 10.1097/00003086-200212000-00019

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  29 in total

1.  A squeaky reputation: the problem may be design-dependent.

Authors:  Javad Parvizi; Bahar Adeli; Justin C Wong; Camilo Restrepo; Richard H Rothman
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

2.  Differences between the wear couples metal-on-polyethylene and ceramic-on-ceramic in the stability against dislocation of total hip replacement.

Authors:  Rainer Bader; Erwin Steinhauser; Susanne Zimmermann; Wolfram Mittelmeier; Roger Scholz; Raymonde Busch
Journal:  J Mater Sci Mater Med       Date:  2004-06       Impact factor: 3.896

3.  Incidence of ceramic liner malseating in Trident acetabular shell.

Authors:  Anna N Miller; Edwin P Su; Mathias P G Bostrom; Bryan J Nestor; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2009-03-12       Impact factor: 4.176

4.  Fractures of a sandwich ceramic liner at ten year follow-up.

Authors:  Anthony Viste; Julien Chouteau; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2011-10-20       Impact factor: 3.075

5.  The 2009 Frank Stinchfield Award: "Hip squeaking": a biomechanical study of ceramic-on-ceramic bearing surfaces.

Authors:  Christophe Chevillotte; Robert T Trousdale; Qingshan Chen; Olivier Guyen; Kai-Nan An
Journal:  Clin Orthop Relat Res       Date:  2009-06-19       Impact factor: 4.176

6.  Delta ceramic-on-alumina ceramic articulation in primary THA: prospective, randomized FDA-IDE study and retrieval analysis.

Authors:  Adolph V Lombardi; Keith R Berend; Brian E Seng; Ian C Clarke; Joanne B Adams
Journal:  Clin Orthop Relat Res       Date:  2010-02       Impact factor: 4.176

7.  Suboptimal Component Position Leading to Severe Wear of an Alumina-Alumina Total Hip Coupling: Biomechanical Analysis and Documentation of Limited Tissue Response.

Authors:  Jaime A Carvajal Alba; Marcella E Elpers; Andrew E Rosenberg; Raymond P Robinson
Journal:  HSS J       Date:  2015-05-27

8.  The Hard on Hard Bearings in THA - Current concepts.

Authors:  P Gopinathan
Journal:  J Orthop       Date:  2014-09-19

9.  Incidence of 'squeaking' after ceramic-on-ceramic total hip arthroplasty.

Authors:  Kenny Mai; Christopher Verioti; Kace A Ezzet; Steven N Copp; Richard H Walker; Clifford W Colwell
Journal:  Clin Orthop Relat Res       Date:  2010-02       Impact factor: 4.176

10.  Alumina inlay failure in cemented polyethylene-backed total hip arthroplasty.

Authors:  Kentaro Iwakiri; Hiroyoshi Iwaki; Yukihide Minoda; Hirotsugu Ohashi; Kunio Takaoka
Journal:  Clin Orthop Relat Res       Date:  2008-02-21       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.