Literature DB >> 20505980

Quality assurance of an image guided intracranial stereotactic positioning system for radiosurgery treatment with helical tomotherapy.

Emilie T Soisson1, Nick Hardcastle, Wolfgang A Tomé.   

Abstract

The aim of this work was to determine the accuracy and precision of stereotactic localization and treatment delivery using a helical tomotherapy based stereotactic radiosurgery (SRS) system. A tomotherapy specific radiosurgery workflow was designed that exploits the system's on board megavotage CT (MVCT) imaging system so that it not only provides a pre-treatment volumetric verification image that can be used for stereotactic localization, eliminating the need for a patient-frame based coordinate system, but also supplies the treatment planning image. Using an imaging guidance based intracranial stereotactic positioning system, a head ring and tabletop docking device are used only for fixation, while image guidance is used for localization. Due to the unconventional workflow, a methodology for determining the localization accuracy was developed and results were compared to other linear accelerator based radiosurgery systems. In this work, the localization error using volumetric localization was found to be 0.45 mm +/- 0.17 mm, indicating a localization precision of 0.3 mm within a 95% confidence interval. In addition, procedures for testing the delivery accuracy of the Tomotherapy system are described. Results show that the accuracy of the delivery can be verified to within +/-1 voxel dimension. These results are well within conventional SRS tolerances and compare favorably to other linear accelerator based techniques.

Entities:  

Mesh:

Year:  2010        PMID: 20505980     DOI: 10.1007/s11060-010-0227-4

Source DB:  PubMed          Journal:  J Neurooncol        ISSN: 0167-594X            Impact factor:   4.130


  11 in total

1.  The University of Florida radiosurgery system.

Authors:  W A Friedman; F J Bova
Journal:  Surg Neurol       Date:  1989-11

2.  Dosimetric verification of helical tomotherapy for total scalp irradiation.

Authors:  Nicholas Hardcastle; Emilie Soisson; Peter Metcalfe; Anatoly B Rosenfeld; Wolfgang A Tome
Journal:  Med Phys       Date:  2008-11       Impact factor: 4.071

3.  A technique for the quantitative evaluation of dose distributions.

Authors:  D A Low; W B Harms; S Mutic; J A Purdy
Journal:  Med Phys       Date:  1998-05       Impact factor: 4.071

4.  Linear accelerator as a neurosurgical tool for stereotactic radiosurgery.

Authors:  K R Winston; W Lutz
Journal:  Neurosurgery       Date:  1988-03       Impact factor: 4.654

5.  Stereotaxic frame and computer software for CT-directed neurosurgical localization.

Authors:  R A Brown; T S Roberts; A G Osborn
Journal:  Invest Radiol       Date:  1980 Jul-Aug       Impact factor: 6.016

6.  Linear accelerator radiosurgery at the University of Florida.

Authors:  W A Friedman; F J Bova; R Spiegelmann
Journal:  Neurosurg Clin N Am       Date:  1992-01       Impact factor: 2.509

7.  Intracranial stereotactic positioning systems: Report of the American Association of Physicists in Medicine Radiation Therapy Committee Task Group no. 68.

Authors:  A W Lightstone; Stanley H Benedict; Frank J Bova; Timothy D Solberg; Robin L Stern
Journal:  Med Phys       Date:  2005-07       Impact factor: 4.071

8.  Automatic registration of megavoltage to kilovoltage CT images in helical tomotherapy: an evaluation of the setup verification process for the special case of a rigid head phantom.

Authors:  Sarah Boswell; Wolfgang Tomé; Robert Jeraj; Hazim Jaradat; T Rock Mackie
Journal:  Med Phys       Date:  2006-11       Impact factor: 4.071

9.  Commissioning and quality assurance of an optically guided three-dimensional ultrasound target localization system for radiotherapy.

Authors:  Wolfgang A Tomé; Sanford L Meeks; Nigel P Orton; Lionel G Bouchet; Francis J Bova
Journal:  Med Phys       Date:  2002-08       Impact factor: 4.071

10.  Endo-rectal balloon cavity dosimetry in a phantom: performance under IMRT and helical tomotherapy beams.

Authors:  Nicholas Hardcastle; Peter E Metcalfe; Anatoly B Rosenfeld; Wolfgang A Tomé
Journal:  Radiother Oncol       Date:  2009-03-30       Impact factor: 6.280

View more
  3 in total

1.  Radiation Necrosis Secondary to Trigeminal Nerve TomoTherapy: A Cautionary Case Study.

Authors:  Andrew Montoure; Hasan Zaidi; John P Sheehy; Andrew G Shetter; Robert Spetzler
Journal:  Cureus       Date:  2015-01-26

2.  Treatment of single or multiple brain metastases by hypofractionated stereotactic radiotherapy using helical tomotherapy.

Authors:  Aiko Nagai; Yuta Shibamoto; Masanori Yoshida; Koichi Wakamatsu; Yuzo Kikuchi
Journal:  Int J Mol Sci       Date:  2014-04-22       Impact factor: 5.923

3.  Clinical commissioning of a new patient positioning system, SyncTraX FX4, for intracranial stereotactic radiotherapy.

Authors:  Satoshi Tanabe; Osamu Umetsu; Toshikazu Sasage; Satoru Utsunomiya; Ryota Kuwabara; Toshiki Kuribayashi; Hiromasa Takatou; Gen Kawaguchi; Hidefumi Aoyama
Journal:  J Appl Clin Med Phys       Date:  2018-10-01       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.