Automatic registration of megavoltage to kilovoltage CT images in helical tomotherapy: an evaluation of the setup verification process for the special case of a rigid head phantom.

Sarah Boswell1, Wolfgang Tomé, Robert Jeraj, Hazim Jaradat, T Rock Mackie.   

Abstract

Precise daily target localization is necessary to achieve highly conformal radiation delivery. In helical tomotherapy, setup verification may be accomplished just prior to delivering each fraction by acquiring a megavoltage CT scan of the patient in the treatment position. This daily image set may be manually or automatically registered to the image set on which the treatment plan was calculated, in order to determine any needed adjustments. The system was tested by acquiring 104 MVCT scans of an anthropomorphic head phantom to which translational displacements had been introduced with respect to the planning image set. Registration results were compared against an independent, optically guided positioning system. The total experimental uncertainty was within approximately 1 mm. Although the registration of phantom images is not fully analogous to the registration of patient images, this study confirms that the system is capable of phantom localization with sub-voxel accuracy. In seven registration problems considered, expert human observers were able to perform manual registrations with comparable or inferior accuracy to automatic registration by mutual information. The time to compute an automatic registration is considerably shorter than the time required for manual registration. However, human evaluation of automatic results is necessary in order to identify occasional outliers, and to ensure that the registration is clinically acceptable, especially in the case of deformable patient anatomy.

Entities:  

Mesh:

Year:  2006        PMID: 17153418     DOI: 10.1118/1.2349698

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  12 in total

1.  Feasibility of intrafraction whole-body motion tracking for total marrow irradiation.

Authors:  Manju Sharma; Troy Dos Santos; Nikolaos P Papanikolopoulos; Susanta Kumar Hui
Journal:  J Biomed Opt       Date:  2011-05       Impact factor: 3.170

2.  Quality assurance of an image guided intracranial stereotactic positioning system for radiosurgery treatment with helical tomotherapy.

Authors:  Emilie T Soisson; Nick Hardcastle; Wolfgang A Tomé
Journal:  J Neurooncol       Date:  2010-05-27       Impact factor: 4.130

3.  Whole brain radiotherapy with hippocampal avoidance and simultaneously integrated brain metastases boost: a planning study.

Authors:  Alonso N Gutiérrez; David C Westerly; Wolfgang A Tomé; Hazim A Jaradat; Thomas R Mackie; Søren M Bentzen; Deepak Khuntia; Minesh P Mehta
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-10-01       Impact factor: 7.038

4.  Three-dimensional patient setup errors at different treatment sites measured by the Tomotherapy megavoltage CT.

Authors:  S K Hui; E Lusczek; T DeFor; K Dusenbery; S Levitt
Journal:  Strahlenther Onkol       Date:  2012-03-09       Impact factor: 3.621

5.  Multi-system verification of registrations for image-guided radiotherapy in clinical trials.

Authors:  Yunfeng Cui; James M Galvin; William L Straube; Walter R Bosch; James A Purdy; X Allen Li; Ying Xiao
Journal:  Int J Radiat Oncol Biol Phys       Date:  2011-01-13       Impact factor: 7.038

6.  Dose escalated, hypofractionated radiotherapy using helical tomotherapy for inoperable non-small cell lung cancer: preliminary results of a risk-stratified phase I dose escalation study.

Authors:  J B Adkison; D Khuntia; S M Bentzen; G M Cannon; W A Tome; H Jaradat; W Walker; A M Traynor; T Weigel; M P Mehta
Journal:  Technol Cancer Res Treat       Date:  2008-12

7.  Clinical Assessment of 2D/3D Registration Accuracy in 4 Major Anatomic Sites Using On-Board 2D Kilovoltage Images for 6D Patient Setup.

Authors:  Guang Li; T Jonathan Yang; Hugo Furtado; Wolfgang Birkfellner; Åse Ballangrud; Simon N Powell; James Mechalakos
Journal:  Technol Cancer Res Treat       Date:  2014-09-15

8.  A comprehensive assessment by tumor site of patient setup using daily MVCT imaging from more than 3,800 helical tomotherapy treatments.

Authors:  Leah K Schubert; David C Westerly; Wolfgang A Tomé; Minesh P Mehta; Emilie T Soisson; Thomas R Mackie; Mark A Ritter; Deepak Khuntia; Paul M Harari; Bhudatt R Paliwal
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-03-15       Impact factor: 7.038

9.  Comparison of gross tumor volume of primary oesophageal cancer based on contrast-enhanced three-dimensional, four-dimensional, and cone beam computed tomography.

Authors:  Chao-Yue Hu; Jian-Bin Li; Jin-Zhi Wang; Wei Wang; Feng-Xiang Li; Yan-Luan Guo
Journal:  Oncotarget       Date:  2017-10-05

10.  Is daily CT image guidance necessary for nasal cavity and nasopharyngeal radiotherapy: an investigation based on helical tomotherapy.

Authors:  Ke Sheng; Jennifer Chow; Grant Hunter; James Larner; Paul Read
Journal:  J Appl Clin Med Phys       Date:  2008-01-28       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.