Literature DB >> 20464460

Evaluation of the stress distribution in CFR-PEEK dental implants by the three-dimensional finite element method.

João Rodrigo Sarot1, Cintia Mussi Milani Contar, Ariadne Cristiane Cabral da Cruz, Ricardo de Souza Magini.   

Abstract

CFR-PEEK (carbon fiber reforced-poly ether ether ketone) has been demonstrated to be excellent substitute titanium in orthopedic applications and can be manufactured with many physical, mechanical, and surface properties, in several shapes. The aim of this study was to compare, using the three-dimensional finite element method, the stress distribution in the peri-implant support bone of distinct models composed of PEEK components and implants reinforced with 30% carbon fiber (30% CFR-PEEK) or titanium. In simulations with a perfect bonding between the bone and the implant, the 30% CFR-PEEK presented higher stress concentration in the implant neck and the adjacent bone, due to the decreased stiffness and higher deformation in relation to the titanium. However, 30% CFR-PEEK implants and components did not exhibit any advantages in relation to the stress distribution compared to the titanium implants and components.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20464460     DOI: 10.1007/s10856-010-4084-7

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  33 in total

1.  Bone loading pattern around implants in average and atrophic edentulous maxillae: a finite-element analysis.

Authors:  Ulrich Meyer; Dirk Vollmer; Christoph Runte; Christoph Bourauel; Ulrich Joos
Journal:  J Maxillofac Surg       Date:  2001-04

2.  Performance study of braided carbon/PEEK composite compression bone plates.

Authors:  K Fujihara; Zheng-Ming Huang; S Ramakrishna; K Satknanantham; H Hamada
Journal:  Biomaterials       Date:  2003-07       Impact factor: 12.479

3.  Implant design and interface force transfer. A photoelastic and strain-gauge analysis.

Authors:  Murat Cehreli; Joke Duyck; Michel De Cooman; Robert Puers; Ignace Naert
Journal:  Clin Oral Implants Res       Date:  2004-04       Impact factor: 5.977

4.  Numerical investigations of the influence of implant shape on stress distribution in the jaw bone.

Authors:  D Siegele; U Soltesz
Journal:  Int J Oral Maxillofac Implants       Date:  1989       Impact factor: 2.804

5.  Polyetheretherketone as a biomaterial for spinal applications.

Authors:  Jeffrey M Toth; Mei Wang; Bradley T Estes; Jeffrey L Scifert; Howard B Seim; A Simon Turner
Journal:  Biomaterials       Date:  2005-08-22       Impact factor: 12.479

6.  Finite element analysis of effect of prosthesis height, angle of force application, and implant offset on supporting bone.

Authors:  Murat Sütpideler; Steven E Eckert; Mark Zobitz; Kai-Nan An
Journal:  Int J Oral Maxillofac Implants       Date:  2004 Nov-Dec       Impact factor: 2.804

7.  Biomechanical aspects of oral implants. Consensus report of Working Group 1.

Authors:  J A Hobkirk; H W A Wiskott
Journal:  Clin Oral Implants Res       Date:  2006-10       Impact factor: 5.977

8.  Composite technology for total hip arthroplasty.

Authors:  H B Skinner
Journal:  Clin Orthop Relat Res       Date:  1988-10       Impact factor: 4.176

9.  Three-dimensional finite-element analysis of functional stresses in different bone locations produced by implants placed in the maxillary posterior region of the sinus floor.

Authors:  Omer Lutfi Koca; Gurcan Eskitascioglu; Aslihan Usumez
Journal:  J Prosthet Dent       Date:  2005-01       Impact factor: 3.426

10.  In vitro biocompatibility of polyetheretherketone and polysulfone composites.

Authors:  L M Wenz; K Merritt; S A Brown; A Moet; A D Steffee
Journal:  J Biomed Mater Res       Date:  1990-02
View more
  14 in total

Review 1.  Polyetheretherketone (PEEK) for medical applications.

Authors:  Ivan Vladislavov Panayotov; Valérie Orti; Frédéric Cuisinier; Jacques Yachouh
Journal:  J Mater Sci Mater Med       Date:  2016-06-03       Impact factor: 3.896

2.  Stress distribution around different abutments on titanium and CFR-PEEK implant with different prosthetic crowns under parafunctional loading: A 3D FEA study.

Authors:  Akanksha Mourya; Rajvi Nahar; Sunil Kumar Mishra; Ramesh Chowdhary
Journal:  J Oral Biol Craniofac Res       Date:  2021-03-16

Review 3.  PEEK with Reinforced Materials and Modifications for Dental Implant Applications.

Authors:  Fitria Rahmitasari; Yuichi Ishida; Kosuke Kurahashi; Takashi Matsuda; Megumi Watanabe; Tetsuo Ichikawa
Journal:  Dent J (Basel)       Date:  2017-12-15

Review 4.  Recent Advances in Material and Geometrical Modelling in Dental Applications.

Authors:  Waleed M S Al Qahtani; Salah A Yousief; Mohamed I El-Anwar
Journal:  Open Access Maced J Med Sci       Date:  2018-06-17

Review 5.  Review on Development and Dental Applications of Polyetheretherketone-Based Biomaterials and Restorations.

Authors:  Ludan Qin; Shuo Yao; Jiaxin Zhao; Chuanjian Zhou; Thomas W Oates; Michael D Weir; Junling Wu; Hockin H K Xu
Journal:  Materials (Basel)       Date:  2021-01-15       Impact factor: 3.623

6.  Biomechanical evaluation of a customized 3D-printed polyetheretherketone condylar prosthesis.

Authors:  Fang Guo; Shuo Huang; Min Hu; Chuncheng Yang; Dichen Li; Changkui Liu
Journal:  Exp Ther Med       Date:  2021-02-11       Impact factor: 2.447

7.  Evaluation of the Bioactivity of Surface Modified Polyetheretherketone (PEEK) as an Implant Material: An In Vitro Study.

Authors:  Asish Martin; N S Azhagarasan; Mahadevan Ravichandran; Hariharan Ramakrishnan; S Jaya Krishnakumar; Vallabh Mahadevan
Journal:  Contemp Clin Dent       Date:  2020-12-20

8.  Antibacterial activity, bio-compatibility and osteogenic differentiation of graphene oxide coating on 3D-network poly-ether-ether-ketone for orthopaedic implants.

Authors:  Cui Guo; Ran Lu; Xin Wang; Su Chen
Journal:  J Mater Sci Mater Med       Date:  2021-10-26       Impact factor: 3.896

Review 9.  Nanomodified Peek Dental Implants: Bioactive Composites and Surface Modification-A Review.

Authors:  Shariq Najeeb; Zohaib Khurshid; Jukka Pekka Matinlinna; Fahad Siddiqui; Mohammad Zakaria Nassani; Kusai Baroudi
Journal:  Int J Dent       Date:  2015-10-01

10.  3D FEA Study On Implant Threading Role on Selection of Implant and Crown Materials.

Authors:  Ahmad Mohamad Wazeh; Mohamed I El-Anwar; Rami M Galal Atia; Rana Mohammed Mahjari; Sara Abdulelah Linga; Linah Mujeeb Alhaq Al-Pakistani; Salah Abdulazim Yousief
Journal:  Open Access Maced J Med Sci       Date:  2018-09-11