Literature DB >> 20463530

Pushing the envelope: new computed tomography techniques for cardiothoracic imaging.

Thomas G Flohr1, Ernst Klotz, Thomas Allmendinger, Rainer Raupach, Herbert Bruder, Bernhard Schmidt.   

Abstract

Multidetector row computed tomography (MDCT) has been used for cardiothoracic imaging since the advent of 4-slice computed tomography (CT) in 1999. Available since 2004, 64-slice CT systems are currently considered a prerequisite for successfully integrating cardiothoracic CT into routine clinical algorithms. Developments are ongoing that aim to solve the remaining challenges of cardiothoracic CT. In this review article, we focus on 3 aspects that have significantly influenced the design of newer CT scanners. (1) A faster scan speed enables coverage of the cardiothoracic anatomy in shorter scan times, which is beneficial for patients with limited ability to cooperate and opens new clinical possibilities. A coveted goal for cardiac CT is a "snapshot image" of the entire heart in 1 cardiac cycle, which can be obtained by using MDCT systems with area detectors or dual-source CT systems with electrocardiogram (ECG)-triggered high-pitch spiral. (2) Techniques to reduce the radiation dose to the patient, such as ECG-controlled dose modulation, ECG-triggered sequential CT, low kV scanning, and iterative reconstruction, have gained considerable attention as a consequence of the ongoing discussion of radiation exposure by CT. (3) New developments aim to establish a role for CT in the functional imaging of the lung and of the heart beyond the mere visualization of anatomy. Evaluation of the first-pass enhancement of the myocardium, with single-energy or with dual-energy data acquisition, and cardiac perfusion examinations may have the potential to enhance the application spectrum of cardiac CT by providing the means to determine the hemodynamic relevance of coronary artery stenosis.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20463530     DOI: 10.1097/RTI.0b013e3181d7e898

Source DB:  PubMed          Journal:  J Thorac Imaging        ISSN: 0883-5993            Impact factor:   3.000


  10 in total

1.  Third-generation dual-source 70-kVp chest CT angiography with advanced iterative reconstruction in young children: image quality and radiation dose reduction.

Authors:  Oliver Rompel; Martin Glöckler; Rolf Janka; Sven Dittrich; Robert Cesnjevar; Michael M Lell; Michael Uder; Matthias Hammon
Journal:  Pediatr Radiol       Date:  2016-01-06

2.  Accuracy, image quality and radiation dose comparison of high-pitch spiral and sequential acquisition on 128-slice dual-source CT angiography in children with congenital heart disease.

Authors:  Pei Nie; Ximing Wang; Zhaoping Cheng; Xiaopeng Ji; Yanhua Duan; Jiuhong Chen
Journal:  Eur Radiol       Date:  2012-05-18       Impact factor: 5.315

Review 3.  Infarct characterization using CT.

Authors:  Ludovico La Grutta; Patrizia Toia; Erica Maffei; Filippo Cademartiri; Roberto Lagalla; Massimo Midiri
Journal:  Cardiovasc Diagn Ther       Date:  2017-04

4.  Dose reduction in oncological staging multidetector CT: effect of iterative reconstruction.

Authors:  M Karpitschka; D Augart; H-C Becker; M Reiser; A Graser
Journal:  Br J Radiol       Date:  2013-01       Impact factor: 3.039

5.  Sinogram Affirmed Iterative Reconstruction (SAFIRE) versus weighted filtered back projection (WFBP) effects on quantitative measure in the COPDGene 2 test object.

Authors:  J P Sieren; E A Hoffman; M K Fuld; K S Chan; J Guo; J D Newell
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

6.  Utility of dual source CT with ECG-triggered high-pitch spiral acquisition (Flash Spiral Cardio mode) to evaluate morphological features of ventricles in children with complex congenital heart defects.

Authors:  Motoo Nakagawa; Yoshiyuki Ozawa; Norikazu Nomura; Sachiko Inukai; Satoshi Tsubokura; Keita Sakurai; Masashi Shimohira; Masaki Ogawa; Yuta Shibamoto
Journal:  Jpn J Radiol       Date:  2016-01-28       Impact factor: 2.374

7.  High-pitch computed tomography coronary angiography-a new dose-saving algorithm: estimation of radiation exposure.

Authors:  Dominik Ketelsen; Markus Buchgeister; Andreas Korn; Michael Fenchel; Bernhard Schmidt; Thomas G Flohr; Christoph Thomas; Christoph Schabel; Ilias Tsiflikas; Roland Syha; Claus D Claussen; Martin Heuschmid
Journal:  Radiol Res Pract       Date:  2012-05-31

8.  Energy Limits in Second Generation High-pitch Dual Source CT - Comparison in an Upper Abdominal Phantom.

Authors:  Martin Beeres; Ralf W Bauer; Josef M Kerl; Thomas J Vogl; Clara Lee
Journal:  J Clin Imaging Sci       Date:  2015-01-30

9.  The future of hybrid imaging-part 2: PET/CT.

Authors:  Thomas Beyer; David W Townsend; Johannes Czernin; Lutz S Freudenberg
Journal:  Insights Imaging       Date:  2011-02-20

10.  Crown years for non-invasive cardiovascular imaging (Part IV): 30 years of cardiac computed tomography.

Authors:  E E van der Wall
Journal:  Neth Heart J       Date:  2013-07       Impact factor: 2.380

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.